Molecular weight distribution characterization of reactive higher ethyleneamines using size-exclusion chromatography with conventional calibration

被引:1
|
作者
Eghbali, Hamed [1 ]
Hagen, Henk [2 ]
Van Engelen, Marcel [1 ]
Meertens, Willy [1 ]
Schweizer-Theobaldt, Andreas [3 ]
Meunier, David [4 ]
机构
[1] Dow Benelux BV, Core R&D Analyt Sci, NL-4530 AA Terneuzen, Netherlands
[2] Dow Benelux BV, Packaging & Specialty Plast R&D, NL-4530 AA Terneuzen, Netherlands
[3] Dow Deutschland GmbH, Core R&D Analyt Sci, D-77836 Rheinmunster, Germany
[4] Dow Chem Co USA, Core R&D Analyt Sci, Midland, MI 48674 USA
关键词
Ethyleneamines; Size-exclusion chromatography; MWD characterization; Conventional calibration; LIGHT-SCATTERING;
D O I
10.1016/j.chroma.2019.06.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ethyleneamines have been produced and commercialized for decades in the chemical industry for a diverse range of applications. The presence of amine functional groups provides them opportunity to adsorb onto surfaces which can make them a very challenging sample matrix to analyze using separation techniques. In the present report, a new aqueous SEC-RI method, which enables MWD characterization of higher ethyleneamines, is described. The sample preparation was based on the dilute-and-shoot methodology. A surface-modified SEC column with positively charged groups attached to the stationary phase was used. The mobile phase composition (salt concentration, pH) was optimized to suppress interaction between the ethyleneamines and the packing material. Very symmetrical peak shapes were achieved for low MW monodisperse ethyleneamines despite their high primary amine content. MWD calculations were conducted using conventional narrow standard calibration with partial linear extrapolation of the calibration curve. The narrow standards were of the same chemistry as the samples of interest. Consequently, the standard components display a consistent behaviour towards the column packing as the sample components which makes the present method more robust and the interpretation of the quantitative results more convenient. Effect on the measured MW averages and MW distribution due to various experimental parameters (e.g., system variability, mobile phase preparation, sample concentration) were investigated showing good repeatability (RSD < 2%) for M-n. M-w, and M-z. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 149
页数:9
相关论文
共 50 条
  • [31] Thermodynamic equilibrium of the solute distribution in size-exclusion chromatography
    Striegel, AM
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) : 241 - 245
  • [32] Purification of bacteriocins using size-exclusion chromatography
    Rather, Irfan A.
    Hamad, Alshammari Fanar
    Bajpai, Vivek K.
    BANGLADESH JOURNAL OF PHARMACOLOGY, 2016, 11 (02) : 281 - 284
  • [33] DIFFERENTIAL MOLECULAR-WEIGHT DISTRIBUTIONS IN HIGH-PERFORMANCE SIZE-EXCLUSION CHROMATOGRAPHY
    SHORTT, DW
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (16): : 3371 - 3391
  • [34] SIZE-EXCLUSION CHROMATOGRAPHY OF HIGH-MOLECULAR-WEIGHT WATER-SOLUBLE POLYMERS
    SAFIEDDINE, AM
    HESTER, RD
    JOURNAL OF APPLIED POLYMER SCIENCE, 1991, 43 (11) : 1987 - 1990
  • [35] Determination of the pore size distribution and porosity of aerobic granules using size-exclusion chromatography
    Zheng, Yu-Ming
    Yu, Han-Qing
    WATER RESEARCH, 2007, 41 (01) : 39 - 46
  • [36] Characterization of AOX by fractionation analysis and size-exclusion chromatography
    Gremm, TJ
    Frimmel, FH
    ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 2000, 28 (04): : 202 - 211
  • [37] Polymer characterization by size-exclusion chromatography with multiple detection
    Laguna, MTR
    Medrano, R
    Plana, MP
    Tarazona, MP
    JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) : 13 - 19
  • [38] CHARACTERIZATION OF HEMODIALYSIS MEMBRANES BY INVERSE SIZE-EXCLUSION CHROMATOGRAPHY
    BROEK, AP
    TEUNIS, HA
    BARGEMAN, D
    SPRENGERS, ED
    STRATHMANN, H
    SMOLDERS, CA
    JOURNAL OF MEMBRANE SCIENCE, 1995, 99 (03) : 217 - 228
  • [39] Size-exclusion chromatography for the characterization of urinary extracellular vesicles
    Park, Sanghwi
    Jalaludin, Iqbal
    Hwang, Hyojin
    Ko, Minjeong
    Adelipour, Maryam
    Hwan, Myung
    Cho, Namjoon
    Kim, Kee K.
    Lubman, David M.
    Kim, Jeongkwon
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1228
  • [40] CALIBRATION OF SIZE-EXCLUSION CHROMATOGRAPHY - USE OF A DOUBLE GAUSSIAN DISTRIBUTION FUNCTION TO DESCRIBE PORE SIZES
    HARLAN, JE
    PICOT, D
    LOLL, PJ
    GARAVITO, RM
    ANALYTICAL BIOCHEMISTRY, 1995, 224 (02) : 557 - 563