Molecular weight distribution characterization of reactive higher ethyleneamines using size-exclusion chromatography with conventional calibration

被引:1
|
作者
Eghbali, Hamed [1 ]
Hagen, Henk [2 ]
Van Engelen, Marcel [1 ]
Meertens, Willy [1 ]
Schweizer-Theobaldt, Andreas [3 ]
Meunier, David [4 ]
机构
[1] Dow Benelux BV, Core R&D Analyt Sci, NL-4530 AA Terneuzen, Netherlands
[2] Dow Benelux BV, Packaging & Specialty Plast R&D, NL-4530 AA Terneuzen, Netherlands
[3] Dow Deutschland GmbH, Core R&D Analyt Sci, D-77836 Rheinmunster, Germany
[4] Dow Chem Co USA, Core R&D Analyt Sci, Midland, MI 48674 USA
关键词
Ethyleneamines; Size-exclusion chromatography; MWD characterization; Conventional calibration; LIGHT-SCATTERING;
D O I
10.1016/j.chroma.2019.06.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ethyleneamines have been produced and commercialized for decades in the chemical industry for a diverse range of applications. The presence of amine functional groups provides them opportunity to adsorb onto surfaces which can make them a very challenging sample matrix to analyze using separation techniques. In the present report, a new aqueous SEC-RI method, which enables MWD characterization of higher ethyleneamines, is described. The sample preparation was based on the dilute-and-shoot methodology. A surface-modified SEC column with positively charged groups attached to the stationary phase was used. The mobile phase composition (salt concentration, pH) was optimized to suppress interaction between the ethyleneamines and the packing material. Very symmetrical peak shapes were achieved for low MW monodisperse ethyleneamines despite their high primary amine content. MWD calculations were conducted using conventional narrow standard calibration with partial linear extrapolation of the calibration curve. The narrow standards were of the same chemistry as the samples of interest. Consequently, the standard components display a consistent behaviour towards the column packing as the sample components which makes the present method more robust and the interpretation of the quantitative results more convenient. Effect on the measured MW averages and MW distribution due to various experimental parameters (e.g., system variability, mobile phase preparation, sample concentration) were investigated showing good repeatability (RSD < 2%) for M-n. M-w, and M-z. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 149
页数:9
相关论文
共 50 条
  • [1] Molecular weight distribution characterization of hydrophobe-modified hydroxyethyl cellulose by size-exclusion chromatography
    Li, Yongfu
    Meunier, David M.
    Partain, Emmett M.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1359 : 182 - 188
  • [2] Size-exclusion chromatography of low molecular weight polymers
    Mrkvičková, Libuše
    Journal of Liquid Chromatography and Related Technologies, 1997, 20 (03): : 403 - 411
  • [3] Evaluation of size-exclusion chromatography and size-exclusion electrochromatography calibration curves
    Vander Heyden, Y
    Popovici, ST
    Schoenmakers, PJ
    JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (02) : 127 - 137
  • [4] Size-exclusion chromatography study of the molecular-weight distribution of γ-irradiated pullulan
    Shingel, KI
    Tsarenkov, VM
    Petrov, PT
    CARBOHYDRATE RESEARCH, 2000, 324 (04) : 283 - 287
  • [5] Size-exclusion chromatography of low molecular weight polymers
    Mrkvickova, L
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (03) : 403 - 411
  • [6] Size-exclusion chromatography of ultrahigh molecular weight methylcellulose ethers and hydroxypropyl methylcellulose ethers for reliable molecular weight distribution characterization
    Li, Yongfu
    Shen, Hongwei
    Lyons, John W.
    Sammler, Robert L.
    Brackhagen, Meinolf
    Meunier, David M.
    CARBOHYDRATE POLYMERS, 2016, 138 : 290 - 300
  • [7] MOLECULAR MASS CALIBRATION IN SIZE-EXCLUSION CHROMATOGRAPHY OF COAL DERIVATIVES
    BARTLE, KD
    MULLIGAN, MJ
    TAYLOR, N
    MARTIN, TG
    SNAPE, CE
    FUEL, 1984, 63 (11) : 1556 - 1560
  • [8] NEW CALIBRATION METHODS IN SIZE-EXCLUSION CHROMATOGRAPHY
    ROSSET, R
    HUI, F
    XIE, J
    MACHTALERE, G
    KOLODZIEJCZYK, H
    SASSIAT, P
    ANALUSIS, 1994, 22 (06) : 293 - 304
  • [9] Size-exclusion chromatography - a review of calibration methodologies
    Kostanski, LK
    Keller, DM
    Hamielec, AE
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2004, 58 (02): : 159 - 186
  • [10] Determination of molecular-weight distribution of dextran for injection by size-exclusion chromatography and study for molecular-weight standards
    Yomota, C
    Okada, S
    BUNSEKI KAGAKU, 1997, 46 (12) : 979 - 985