Measurement of serum 17-hydroxyprogesterone using isotope dilution liquid chromatography-tandem mass spectrometry candidate reference method and evaluation of the performance for three routine methods

被引:4
|
作者
Long, Qichen [1 ]
Zhang, Tianjiao [2 ]
Yan, Ying [2 ]
Zhao, Haijian [2 ]
Zhou, Weiyan [2 ]
Zeng, Jie [2 ]
Li, Shuijun [3 ]
Zhang, Jiangtao [2 ]
Zeng, Qingzhang [1 ]
Zhao, Beibei [4 ]
Zhang, Chuanbao [1 ]
Chen, Wenxiang [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Chinese Acad Med Sci, Beijing Hosp,Beijing Engn Res Ctr Lab Med, Natl Ctr Gerontol,Inst Geriatr Med,Natl Ctr Clin, 1 Dahua Rd, Beijing 100730, Peoples R China
[2] Chinese Acad Med Sci, Beijing Hosp, Natl Ctr Clin Labs, Natl Ctr Gerontol,Inst Geriatr Med,Beijing Engn R, Beijing, Peoples R China
[3] Shanghai Xuhui Cent Hosp, Cent Lab, Shanghai, Peoples R China
[4] Guangzhou KingMed Diagnost Grp Co Ltd, Guangzhou, Peoples R China
关键词
congenital adrenal hyperplasia; liquid chromatography/tandem mass spectrometry; method evaluation; reference measurement procedure; serum; 17-hydroxyprogesterone; LC-MS/MS; TESTOSTERONE; 17-ALPHA-HYDROXYPROGESTERONE; ANDROSTENEDIONE; QUANTIFICATION; SPECIFICATIONS; DEFICIENCY; CHILDREN;
D O I
10.1515/cclm-2020-0410
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Accurate measurements of serum 17-hydroxyprogesterone (17OHP) are essential for diagnosis and treatment monitoring for congenital adrenal hyperplasia patients. The performance of serum 17OHP routine methods remains highly variable that calls for a candidate reference measurement procedure (cRMP) to improve the standardization of serum 17OHP measurements. Methods: Serum samples spiked with internal standards were extractedwith a combination of solid-phase extraction and liquid-liquid extraction. The 17OHP was quantified by the isotope dilution coupled with liquid chromatography/ tandem mass spectrometry (ID-LC/MS/MS) with electrospray ionization in positive ion mode. Nine structural analogs of 17OHP were evaluated for interferences. The precision and analytical recovery were assessed. Twenty native and 40 spiked serum for performance evaluation were measured by the cRMP and two clinical LC/MS routine methods. Results: No apparent interferences were found with the 17OHP measurement. The within-run, between-run, and total precision for our method were 0.4-0.8%, 0.6-2.0%, and 1.0-2.1% for four pooled serum (2.46-102.72 nmol/L), respectively. The recoveries of added 17OHP were 100.0-100.2%. For the performance of two LC/MS routine methods, they showed relative deviation ranges of -22.1 to 1.1% and -6.7 to 12.8%, respectively. Conclusions: We developed and validated a reliable serum 17OHP method using ID-LC/MS/MS. The desirable accuracy and precision of this method enable it to serve as a promising cRMP to improve the standardization for serum17OHP routine measurements.
引用
收藏
页码:523 / 532
页数:10
相关论文
共 50 条
  • [21] Measurement of serum progesterone by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method and its application to evaluating immunoassays
    Yufei Wang
    Tianjiao Zhang
    Haijian Zhao
    Weiyan Zhou
    Jie Zeng
    Jiangtao Zhang
    Chuanbao Zhang
    Wenxiang Chen
    Analytical and Bioanalytical Chemistry, 2019, 411 : 2363 - 2371
  • [22] Evaluation and clinical application of a bracketing calibration-based isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for serum theophylline
    Du, Yuanyuan
    Yan, Qiaofang
    Zhan, Min
    Zhang, Qiaoxuan
    Huang, Di
    Zhang, Pengwei
    Yan, Jun
    Wang, Jianbing
    Huang, Xianzhang
    Han, Liqiao
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (22) : 4897 - 4906
  • [23] Measurement of serum progesterone by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method and its application to evaluating immunoassays
    Wang, Yufei
    Zhang, Tianjiao
    Zhao, Haijian
    Zhou, Weiyan
    Zeng, Jie
    Zhang, Jiangtao
    Zhang, Chuanbao
    Chen, Wenxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (11) : 2363 - 2371
  • [24] SIMULTANEOUS ANALYSIS OF 11-DEOXYCORTISOL, 17-HYDROXYPROGESTERONE AND CORTISOL BY LIQUID CHROMATOGRAPHY-ISOTOPE DILUTION TANDEM MASS SPECTROMETRY
    Wan, B.
    Yazdanpanah, M.
    Adeli, K.
    Kyriakopoulou, G. L.
    MOLECULAR GENETICS AND METABOLISM, 2009, 98 (1-2) : 108 - 108
  • [25] Testosterone measurement by isotope-dilution liquid chromatography-tandem mass spectrometry: Validation of a method for routine clinical practice
    Cawood, ML
    Field, HP
    Ford, CG
    Gillingwater, S
    Kicman, A
    Cowan, D
    Barth, JH
    CLINICAL CHEMISTRY, 2005, 51 (08) : 1472 - 1479
  • [26] Development and evaluation of a candidate reference measurement procedure for the determination of progesterone in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry
    Tai, Susan S. -C.
    Xu, Bei
    Welch, Michael J.
    ANALYTICAL CHEMISTRY, 2006, 78 (18) : 6628 - 6633
  • [27] Candidate reference measurement procedure for determination of urea in serum by liquid chromatography-tandem mass spectrometry
    Han, Liqiao
    Huang, Xiaoting
    Zhang, Lu
    Zhang, Qiaoxuan
    Wang, Jianbing
    Lin, Haibiao
    Yan, Jun
    Zhuang, Junhua
    Huang, Xianzhang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 162 : 124 - 129
  • [28] Measurement of serum uric acid by isotope dilution liquid chromatography tandem mass spectrometry: Modification of a candidate reference measurement method and its clinical application
    Yan, Jun
    Lin, Haibiao
    Xu, Yuzhu
    Yu, Lintao
    Chen, Song
    Zhang, Qiaoxuan
    Han, Liqiao
    Ou, Yangfen
    Zhan, Min
    Wang, Jianbing
    Ke, Peifeng
    Wang, Yunxiu
    Huang, Xianzhang
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2022, 482
  • [29] An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of cortisol in human serum and plasma
    Ott, Myriam
    Singh, Neeraj
    Bauland, Friederike
    Koeppl, Daniel
    Kandler, Kerstin
    Gaudl, Alexander
    Geistanger, Andrea
    Ceglarek, Uta
    Rauh, Manfred
    Geletneky, Christian
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025,
  • [30] Quantification of mycophenolic acid in plasma by isotope dilution liquid chromatography-tandem mass spectrometry candidate reference methodQuantification of mycophenolic acid in plasma by isotope dilution liquid chromatography-tandem mass spectrometry candidate reference methodJ. Lin et al.
    Jing Lin
    Min Shen
    Ting Yu
    Huimin Wang
    Jingjue Pan
    Gaipeng Huang
    Quanle Li
    Analytical and Bioanalytical Chemistry, 2025, 417 (8) : 1607 - 1617