A Bayesian approach to sample size determination for studies designed to evaluate continuous medical tests

被引:11
|
作者
Cheng, Dunlei [1 ]
Branscum, Adam J. [2 ,3 ,4 ]
Stamey, James D. [5 ]
机构
[1] Baylor Hlth Care Syst, Inst Hlth Care Res & Improvement, Dallas, TX 75206 USA
[2] Univ Kentucky, Dept Biostat, Lexington, KY 40536 USA
[3] Univ Kentucky, Dept Stat, Lexington, KY 40536 USA
[4] Univ Kentucky, Dept Epidemiol, Lexington, KY 40536 USA
[5] Baylor Univ, Dept Stat Sci, Waco, TX 76798 USA
关键词
ROC CURVES; ABSENCE; MODELS;
D O I
10.1016/j.csda.2009.09.024
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We develop a Bayesian approach to sample size and power calculations for cross-sectional studies that are designed to evaluate and compare continuous medical tests. For studies that involve one test or two conditionally independent or dependent tests, we present methods that are applicable when the true disease status of sampled individuals will be available and when it will not. Within a hypothesis testing framework, we consider the goal of demonstrating that a medical test has area under the receiver operating characteristic (ROC) curve that exceeds a minimum acceptable level or another relevant threshold, and the goals of establishing the superiority or equivalence of one test relative to another. A Bayesian average power criterion is used to determine a sample size that will yield high posterior probability, on average, of a future study correctly deciding in favor of these goals. The impacts on Bayesian average power of prior distributions, the proportion of diseased subjects in the Study, and Correlation among tests are investigated through simulation. The computational algorithm we develop involves simulating multiple data sets that are fit with Bayesian models using Gibbs sampling, and is executed by using WinBUGS in tandem with R. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:298 / 307
页数:10
相关论文
共 50 条
  • [21] Bayesian Sample Size Determination for Causal Discovery
    Castelletti, Federico
    Consonni, Guido
    STATISTICAL SCIENCE, 2024, 39 (02) : 305 - 321
  • [22] Bayesian sample size calculations with imperfect diagnostic tests
    Katsis, Athanassios
    Nistazakis, Hector E.
    ADVANCES IN COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING 2005, VOLS 4 A & 4 B, 2005, 4A-4B : 279 - 282
  • [23] Bayesian Sample Size Determination for Binomial Proportions
    M'Lan, Cyr E.
    Joseph, Lawrence
    Wolfson, David B.
    BAYESIAN ANALYSIS, 2008, 3 (02): : 269 - 296
  • [24] Contrast of Bayesian and Classical Sample Size Determination
    Sadia, Farhana
    Hossain, Syed S.
    JOURNAL OF MODERN APPLIED STATISTICAL METHODS, 2014, 13 (02) : 420 - 431
  • [25] Sample size calculations for comparative studies of medical tests for detecting presence of disease
    Alonzo, TA
    Pepe, MS
    Moskowitz, CS
    STATISTICS IN MEDICINE, 2002, 21 (06) : 835 - 852
  • [26] Bayesian sample size planning for developmental studies
    Visser, Ingmar
    Kucharsky, Simon
    Levelt, Claartje
    Stefan, Angelika M.
    Wagenmakers, Eric-Jan
    Oakes, Lisa
    INFANT AND CHILD DEVELOPMENT, 2024, 33 (01)
  • [27] Sample Size Determination for Rasch Model Tests
    Draxler, Clemens
    PSYCHOMETRIKA, 2010, 75 (04) : 708 - 724
  • [28] Sample Size Determination for Rasch Model Tests
    Clemens Draxler
    Psychometrika, 2010, 75 : 708 - 724
  • [29] Determination of the minimum sample size for reliability tests
    Feng, Zhenyu
    Zhu, Depei
    Jixie Qiangdu/Journal of Mechanical Strength, 1999, 21 (03): : 186 - 187
  • [30] ON DETERMINATION OF SAMPLE SIZE TO EVALUATE RELIABILITY GROWTH PLANS
    Jin, X.
    Woytowitz, P.
    Tan, T.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 9, 2012, : 451 - 456