Assessment of the indoor air quality based on airborne bacteria and fungi measurements in a public school of Istanbul

被引:2
|
作者
Sivri, Nuket [1 ]
Dogru, Ahmet Ozgur [2 ]
Bagcigil, Arzu Funda [3 ]
Metiner, Kemal [3 ]
Seker, Dursun Zafer [2 ]
机构
[1] Istanbul Univ Cerrahpasa, Dept Environm Engn, TR-34320 Istanbul, Turkey
[2] Istanbul Tech Univ, Dept Geomat Engn, TR-34469 Istanbul, Turkey
[3] Istanbul Univ Cerrahpasa, Fac Vet Med, Dept Microbiol, Istanbul, Turkey
关键词
GIS; Indoor air quality (IAQ); Culturable airborne bacteria (CAB); Culturable airborne fungi (CAF); Primary schools; Istanbul; EXPOSURE; MOLD; SPORES; HEALTH; MICROORGANISMS; ASSOCIATIONS; POLLUTANTS;
D O I
10.1007/s12517-020-06252-3
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
This study aimed at determining culturable airborne bacteria (CAB) and fungi (CAF) concentrations in different sections of a primary school located in Istanbul. Occupancy variables were determinants of exposure and the environmental, ventilation, and comfort parameters within the study. Air samples were collected twice in the summer and spring seasons using a microbial air sampler (Sampl'air (TM)) and were analyzed in terms of CAB and CAF concentrations. Obtained results were visualized using geographic information system (GIS) technology for presenting the spatial variations of CAB and CAF concentrations with respect to environmental determinants and changing weather conditions as temperature and humidity. The study introduced that the CAB and CAF concentrations vary indoors based on the sampling location and human occupancy. As an interesting finding of the study, CAB (3300 CFU/m(3)) and CAF (3100 CFU/m(3)) concentrations in the 5th classroom, where relative humidity and temperature values were recorded as 62% and 25.3 degrees C, respectively, were observed, confirming higher values than those of communal areas. This result proved the importance of indoor characteristics like location, ventilation, occupation time, and hygiene as the substantial determinants of CAB and CAF exposure besides the indoor population. This study emphasized the importance of regular and systematic monitoring of airborne microorganisms in different sections of schools using objective and quantitative methodologies in terms of providing healthy educational environments for students.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Guide on fungi in indoor environments development by the commission on indoor air quality
    Szewzyk, R.
    VDI Berichte, 2001, (1603): : 67 - 77
  • [22] Indoor exposure to airborne bacteria and fungi in sensitive wards of an academic pediatric hospital
    Seyed Hamed Mirhoseini
    Mojtaba Didehdar
    Majid Akbari
    Rahmatollah Moradzadeh
    Reza Jamshidi
    Sara Torabi
    Aerobiologia, 2020, 36 : 225 - 232
  • [23] Distribution of Airborne Bacteria and Fungi in the Korean High-speed Train Indoor
    Kwon, Soon-Bark
    Cho, Youngmin
    Park, Duck-Shin
    Park, Jaehyung
    Kim, Ki-Youn
    Kim, Changsoo
    EPIDEMIOLOGY, 2011, 22 (01) : S43 - S43
  • [24] Indoor exposure to airborne bacteria and fungi in sensitive wards of an academic pediatric hospital
    Mirhoseini, Seyed Hamed
    Didehdar, Mojtaba
    Akbari, Majid
    Moradzadeh, Rahmatollah
    Jamshidi, Reza
    Torabi, Sara
    AEROBIOLOGIA, 2020, 36 (02) : 225 - 232
  • [25] Indoor air quality in two urban elementary schools-measurements of airborne fungi, carpet allergens,CO2, temperature, and relative humidity
    Ramachandran, G
    Adgate, JL
    Banerjee, S
    Church, TR
    Jones, D
    Fredrickson, A
    Sexton, K
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2005, 2 (11) : 553 - 566
  • [26] An energy impact assessment of ventilation for indoor airborne bacteria exposure risk in air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Chan, W. Y.
    BUILDING AND ENVIRONMENT, 2008, 43 (11) : 1939 - 1944
  • [27] School exposure to air pollution in the UK and Ireland: Indoor-Outdoor air quality assessment
    Parra, M.
    Knowlton, T.
    EUROPEAN JOURNAL OF PUBLIC HEALTH, 2023, 33
  • [28] Active Sampling Procedure of Indoor Air Quality to Evaluate Airborne Fungi in Dental Building of Higher Education Institution
    Sarmin, Nurul 'Izzah Mohd
    Lutfi, Nur Hanan Muhd Idris
    Darus, Fairus Muhamad
    Khan, Hasnah Begum Said Gulam
    ENVIRONMENT-BEHAVIOUR PROCEEDINGS JOURNAL, 2021, 6 : 119 - 126
  • [29] Assessment of microbiological indoor air quality in a public hospital in the city of Agadir, Morocco
    Oulkheir, Said
    Safouan, Halima
    El Housse, Fadwa
    Aghrouch, Mohamed
    Ounine, Khadija
    Douira, Allal
    Chadli, Smail
    PERIODICUM BIOLOGORUM, 2021, 123 (1-2) : 29 - 34
  • [30] Indoor Air Quality Assessment Based ON Grey Classification Method
    Zhang Furen
    Deng Panpan
    Xu Pai
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 3910 - 3913