Intraexaminer reliability, interexaminer reliability, and mean values for nine lower extremity skeletal measures in healthy naval midshipmen

被引:0
|
作者
Jonson, SR [1 ]
Gross, MT [1 ]
机构
[1] USN HOSP, PHYS THERAPY DEPT, GREAT LAKES, IL USA
来源
关键词
skeletal measures; reliability; naval midshipmen;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Physical therapists, athletic trainers, and other health care professionals commonly evaluate static postures and dynamic motions in patients with skeletal malalignments of the lower extremity. Accurate clinical evaluation of these malalignments depends on reliable and valid measures as well as established normal values. The purpose of this study was to document the intraexaminer and interexaminer reliability and mean values for nine static lower extremity skeletal measures in healthy Naval midshipmen. The measures studied were femoral torsion, ankle dorsiflexion, tibial length, leg length discrepancy, genu varus/valgus, medial talonavicular joint bulge, rearfoot angle, arch angle, and foot type classification. Intraexaminer and interexaminer reliability ICCs ranged between .65 and .97, and percentage agreements ranged between 88.8 and 94.4%. Mean absolute difference values all were within acceptable limits for clinical measurement A foot type classification scheme was suggested. The results of this study indicate that the measures investigated are reliable when conducted on healthy Naval midshipmen by experienced examiners. Suggestions for further research are offered.
引用
收藏
页码:253 / 263
页数:11
相关论文
共 22 条
  • [11] Reliability assessment of hyperspectral imaging with the HyperView™ system for lower extremity superficial tissue oxygenation in young healthy volunteers
    Simone F. Kleiss
    Kirsten F. Ma
    Mostafa El Moumni
    Richte C. L. Schuurmann
    Clark J. Zeebregts
    Marieke Haalboom
    Reinoud P. H. Bokkers
    Jean-Paul P. M. de Vries
    Journal of Clinical Monitoring and Computing, 2022, 36 : 713 - 723
  • [12] Reliability assessment of hyperspectral imaging with the HyperView™ system for lower extremity superficial tissue oxygenation in young healthy volunteers
    Kleiss, Simone F.
    Ma, Kirsten F.
    El Moumni, Mostafa
    Schuurmann, Richte C. L.
    Zeebregts, Clark J.
    Haalboom, Marieke
    Bokkers, Reinoud P. H.
    de Vries, Jean-Paul P. M.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (03) : 713 - 723
  • [13] Hand-held dynamometry: Reliability of lower extremity muscle testing in healthy, physically active, young adults
    Kelln, Brent M.
    McKeon, Patrick O.
    Gontkof, Lauren M.
    Hertel, Jay
    JOURNAL OF SPORT REHABILITATION, 2008, 17 (02) : 160 - 170
  • [14] The Validity and Absolute Reliability of Lower Extremity Angle Values on Full-Leg Standing Radiographs Using the TraumaMeter Software
    Leon-Munoz, Vicente J.
    Hurtado-Aviles, Jose
    Moya-Angeler, Joaquin
    Valero-Cifuentes, Gregorio
    Hernandez-Martinez, Irene
    Castillo-Botero, Alejandro J.
    Lante, Erica
    Martinez-Sola, Rocio
    Santonja-Renedo, Fernando
    Sanchez-Martinez, Francisco J.
    Ferrer-Lopez, Vicente
    Salmeron-Martinez, Emilio Jose
    Santonja-Medina, Fernando
    APPLIED SCIENCES-BASEL, 2024, 14 (02):
  • [15] Validity and Reliability of Surface Electromyography Features in Lower Extremity Muscle Contraction in Healthy and Spinal Cord-Injured Participants
    Silverman, Jordan Daniel
    Balbinot, Gustavo
    Masani, Kei
    Zariffa, Jose
    Eng, P.
    TOPICS IN SPINAL CORD INJURY REHABILITATION, 2021, 27 (04) : 14 - 27
  • [16] Reliability of side-to-side ultrasound cross-sectional area measurements of lower extremity nerves in healthy subjects
    Tagliafico, Alberto
    Cadoni, Angela
    Fisci, Erica
    Bignotti, Bianca
    Padua, Luca
    Martinoli, Carlo
    MUSCLE & NERVE, 2012, 46 (05) : 717 - 722
  • [17] Lower extremity strength and power asymmetry assessment in healthy and mobility-limited populations: reliability and association with physical functioning
    Carabello, Robert J.
    Reid, Kieran F.
    Clark, David J.
    Phillips, Edward M.
    Fielding, Roger A.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2010, 22 (04) : 324 - 329
  • [18] Lower extremity strength and power asymmetry assessment in healthy and mobility-limited populations: reliability and association with physical functioning
    Robert J. Carabello
    Kieran F. Reid
    David J. Clark
    Edward M. Phillips
    Roger A. Fielding
    Aging Clinical and Experimental Research, 2010, 22 : 324 - 329
  • [19] The Stroke Upper and Lower Extremity Physical Function Measures Were Supported for Score Reliability, Validity, and Administration Efficiency for Patients Poststroke
    Deutscher, Daniel
    Kallen, Michael A.
    Hayes, Deanna
    Werneke, Mark W.
    Mioduski, Jerome E.
    Toczylowski, Theresa
    Petitti, Jessica M.
    Cook, Karon F.
    PHYSICAL THERAPY, 2023, 103 (11):
  • [20] Lower Extremity Strength Profile in Ambulatory Adults with Cerebral Palsy and Spastic Diplegia: Norm Values and Reliability for Hand-Held Dynamometry
    Eken, Maaike M.
    Lamberts, Robert P.
    Koschnick, Susanne
    Du Toit, Jacques
    Veerbeek, Berendina E.
    Langerak, Nelleke G.
    PM&R, 2020, 12 (06) : 573 - 580