Ultrasensitive electrochemical sensor for mercury (II) based on target-induced structure-switching DNA

被引:156
|
作者
Wu, Danhong [1 ]
Zhang, Qing [1 ]
Chu, Xia [1 ]
Wang, Haibo [1 ]
Shen, Guoli [1 ]
Yu, Ruqin [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemobiosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2010年 / 25卷 / 05期
关键词
Mercury; Electrochemical sensor; Structure-switching DNA; Differential pulse voltammetry; SURFACE HYBRIDIZATION ASSAY; AQUEOUS-SOLUTION; HG-II; COLORIMETRIC DETECTION; SELECTIVE DETECTION; GOLD NANOPARTICLES; SIGNALING APTAMERS; FLUORESCENT SENSOR; PROBES; IONS;
D O I
10.1016/j.bios.2009.09.017
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel electrochemical sensor has been developed for sensitive and selective detection of mercury (II) based on target-induced structure-switching DNA. A 33-mer oligonucleotide 1 with five self-complementary base pairs separated by seven thymine-thymine mismatches was first immobilized on the electrode via self-assembly of the terminal thiol moiety and then hybridized with a ferrocene-tagged oligonucleotide 2, leading to a high redox current. in the presence of Hg2+, mercury-mediated base pairs (T-Hg2+-T) induced the folding of the oligonucleotide 1 into a hairpin structure, resulting in the release of the ferrocene-tagged oligonucleotide 2 from the electrode surface with a substantially decreased redox current. The response characteristics of the sensor were thoroughly investigated using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The effect of the reaction temperature on the response of the sensor was also studied in detail. The results revealed that the sensor showed sensitive response to Hg2+ in a concentration range from 0.1 nM to 5 mu M with a detection limit of 0.06 nM. In addition, this strategy afforded exquisite selectivity for Hg2+ against other environmentally related metal ions, which was superior to that of previous anodic stripping voltammetry (ASV)-based techniques. The excellent sensitivity and selectivity signified the potential of the sensor for Hg2+ detection in real environmental samples. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1025 / 1031
页数:7
相关论文
共 50 条
  • [41] Graphene-Gold Nanoparticle-modified Electrochemical Sensor for Detection of Kanamycin Based on Target-induced Aptamer Displacement
    Zheng Jingyi
    Feng Rongrong
    He Caimei
    Li Xiaoxia
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2018, 34 (06) : 952 - 958
  • [42] Electrochemical Aptamer Biosensor Based on ATP-Induced 2D DNA Structure Switching for Rapid and Ultrasensitive Detection of ATP
    Liu, Ying
    Kong, Lingqi
    Li, Hao
    Yuan, Ruo
    Chai, Yaqin
    ANALYTICAL CHEMISTRY, 2022, 94 (18) : 6819 - 6826
  • [43] A homogeneous microchannel resistance sensor based on target-induced aggregation of polystyrene microspheres
    Nie, Rongbin
    He, Huiyu
    Lu, Peng
    Peng, Xuewen
    Li, Xiaohan
    Chen, Yiping
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 369
  • [44] A universal converting strategy based on target-induced DNA nanoprobe conformational change for lead (II) ion assay
    Yang, Zhehan
    Wu, Hong
    Yi, Xingchen
    Tang, Jiajia
    Yun, Wen
    Han, Wenbo
    Chen, Xingguang
    BIOSENSORS & BIOELECTRONICS, 2019, 144
  • [45] Target-induced aptamer displacement on gold nanoparticles and rolling circle amplification for ultrasensitive live Salmonella typhimurium electrochemical biosensing
    Ge, Chuang
    Yuan, Rui
    Yi, Lin
    Yang, Jingli
    Zhang, Haiwei
    Li, Lixian
    Nian, Weiqi
    Yi, Gang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 826 : 174 - 180
  • [46] A novel ultrasensitive electrochemical DNA sensor based on double tetrahedral nanostructures
    Zeng, Dongdong
    Zhang, Huan
    Zhu, Dan
    Li, Jiang
    San, Lili
    Wang, Zehua
    Wang, Chenguang
    Wang, Yunsheng
    Wang, Lihua
    Zuo, Xiaolei
    Mi, Xianqiang
    BIOSENSORS & BIOELECTRONICS, 2015, 71 : 434 - 438
  • [47] Electrochemical biomimetic enzyme cascade amplification combined with target-induced DNA walker for detection of thrombin
    Pan Xie
    Ding Wang
    Hongwen Zhao
    Na Yin
    Shuang Hu
    Wenhan Qin
    Li Meng
    Xin Pan
    Yali Yuan
    Ruo Yuan
    Kanfu Peng
    Microchimica Acta, 2023, 190
  • [48] Target-Induced DNA Mismatch for One-Spot Simultaneous Electrochemical Detection of Multiple Heavy Metals Based on the Amplification of DNA Concatemers
    Liu, Guangpeng
    Wang, Haijun
    Yuan, Yali
    Wang, Jianli
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (04) : B81 - B85
  • [49] Electrochemical biomimetic enzyme cascade amplification combined with target-induced DNA walker for detection of thrombin
    Xie, Pan
    Wang, Ding
    Zhao, Hongwen
    Yin, Na
    Hu, Shuang
    Qin, Wenhan
    Meng, Li
    Pan, Xin
    Yuan, Yali
    Yuan, Ruo
    Peng, Kanfu
    MICROCHIMICA ACTA, 2023, 190 (05)
  • [50] "Off-On" Electrochemiluminescence System for Sensitive Detection of ATP via Target-Induced Structure Switching
    Liu, Yueting
    Lei, Jianping
    Huang, Yin
    Ju, Huangxian
    ANALYTICAL CHEMISTRY, 2014, 86 (17) : 8735 - 8741