Test beam results for an endcap electromagnetic calorimeter for the SSC

被引:0
|
作者
Abrams, GS
Ashmanskas, W
Bintinger, D
Ciocio, S
Hoff, M
Kadel, RW
Kadyk, J
Minamihara, Y
Lim, A
Long, M
Pope, W
Pripstein, M
Przybylski, G
Thur, W
Weber, T
Yarba, J
Hearty, C
Amadon, A
Bonamy, P
Bystricky, J
Ernwein, J
Glicenstein, JF
Hubbard, JR
LeDu, P
Reymond, JM
Rondeaux, F
Villet, G
Singh, V
Bhatti, A
Melese, P
Hauser, J
Lindgren, M
Muller, T
Cushman, P
Rusack, R
机构
[1] UNIV CALIF BERKELEY,LAWRENCE BERKELEY LAB,DIV PHYS,BERKELEY,CA 94720
[2] FERMILAB NATL ACCELERATOR LAB,BATAVIA,IL 60510
[3] UNIV BRITISH COLUMBIA,VANCOUVER,BC V6T 1Z1,CANADA
[4] CEA SACLAY,DAPNIA,SPP,F-91191 GIF SUR YVETTE,FRANCE
[5] AT&T BELL LABS,HOLMDEL,NJ 07733
[6] ROCKEFELLER UNIV,NEW YORK,NY 10021
[7] UNIV CALIF LOS ANGELES,LOS ANGELES,CA 90024
[8] UNIV MINNESOTA,DEPT PHYS,MINNEAPOLIS,MN 55455
关键词
D O I
10.1016/S0168-9002(97)00381-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have tested a calorimeter test beam module intended to simulate the endcap electromagnetic calorimeter of the Solenoidal Detector Collaboration (SDC) experiment at the SSC. The test module is manufactured from scintillating tiles and is read out via 1 mm diameter wavelength shifting fibers with shower sampling at similar to 1 radiation length intervals. The results of test beam calibration show that the calorimeter is linear to within 1% and has a resolution of (19.5 +/- 0.1)%/root E + (0.47% +/- 0.05)% for energies up to 200 GeV. Test beam data show that non-uniform, longitudinal radiation damage to the calorimeter (up to similar to 50% light loss at shower maximum) can be corrected, and the original linearity of the calorimeter can be recovered with only a small degradation of resolution. A ''pre-shower detector'' improves the charged pi rejection by a factor of 2-3 at an electron detection efficiency greater than 97.5 +/- 0.3%.
引用
收藏
页码:41 / 62
页数:22
相关论文
共 50 条
  • [31] Results of a beam test of the combined lead glass and PWO cells detector for the COMPASS electromagnetic calorimeter
    Dolgopolov, AV
    Donskov, SV
    Fujii, Y
    Inaba, S
    Lednev, AA
    Nakagawa, T
    Prokoshkin, YD
    Shimizu, H
    Shagin, PM
    Singovsky, AV
    Sugonyaev, VP
    Takamatsu, K
    Tsuru, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 420 (1-2): : 20 - 28
  • [32] Results of a beam test of the combined lead glass and PWO cells detector for the COMPASS electromagnetic calorimeter
    IHEP, Moscow, Russia
    Nucl Instrum Methods Phys Res Sect A, 1-2 (20-28):
  • [33] Performance of the ATLAS Liquid Argon Endcap Calorimeter in Beam Tests
    Strizenec, Pavol
    Minaenko, Andrey
    XIII INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2009, 160
  • [34] Fabrication and beam test of a silicon-tungsten electromagnetic calorimeter
    Muhuri, S.
    Mukhopadhyay, S.
    Chandratre, V. B.
    Nayak, T. K.
    Saha, S. Kumar
    Thakur, S.
    Singaraju, R. N.
    Saini, J.
    van den Brink, A.
    Chujo, T.
    Patra, R. Nath
    van Leeuwen, M.
    Khan, S. Ahmad
    Sukhwani, M.
    Nooren, G-J
    Peitzmann, T.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (03):
  • [35] Electron Beam Test of the MPD Electromagnetic Calorimeter on the Pakhra Synchrotron
    Baskov, V. A.
    Bulychjov, S. A.
    Krechetov, Yu F.
    Kulikov, V. V.
    Martemianov, M. A.
    Mamonov, I. A.
    Semenov, A. Yu
    Semenova, I. A.
    Tyapkin, I. A.
    PHYSICS OF PARTICLES AND NUCLEI, 2021, 52 (04) : 663 - 668
  • [36] Electron Beam Test of the MPD Electromagnetic Calorimeter on the Pakhra Synchrotron
    V. A. Baskov
    S. A. Bulychjov
    Yu. F. Krechetov
    V. V. Kulikov
    M. A. Martemianov
    I. A. Mamonov
    A. Yu. Semenov
    I. A. Semenova
    I. A. Tyapkin
    Physics of Particles and Nuclei, 2021, 52 : 663 - 668
  • [37] Studies of the CMS Electromagnetic Calorimeter performance in the electron test beam
    Arcidiacono, Roberta
    XIII INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2009, 160
  • [38] Beam Test Results of the ISS-CREAM Calorimeter
    Zhang, H. G.
    Angelaszek, D.
    Copley, M.
    Han, J. H.
    Huh, H. G.
    Hwang, Y. S.
    Hyun, H. J.
    Jeon, H. B.
    Kim, K. C.
    Kim, M. H.
    Kim, H. J.
    Kwashnak, K.
    Lee, M. H.
    Lundquist, J. P.
    Lutz, L.
    Malinin, A.
    Park, H.
    Park, J. M.
    Picot-Clemente, N.
    Seo, E. S.
    Smith, J.
    Wu, J.
    Yin, Z. Y.
    Yoon, Y. S.
    37TH INTERNATIONAL COSMIC RAY CONFERENCE, ICRC2021, 2022,
  • [39] Beam test results of a CsI calorimeter matrix element
    Missaghian, J.
    Hurley, F.
    Bashkirov, V.
    Colby, B.
    Rykalin, V.
    Kachigiun, S.
    Fusi, D.
    Schulte, R.
    Mckinney, F. Martinez
    Sadrozinski, H.
    Penfold, S.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [40] Test Beam Results and Status of the sPHENIX Calorimeter System
    Connors, Megan E.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,