Use of different segmental multi-frequency bioelectrical impedance devices for analysis of body composition in young adults: comparison with bioelectrical spectroscopy

被引:9
|
作者
Guedes, Dartagnan Pinto [1 ]
Calabrese, Jean Carlos [1 ]
Pirolli, Paulo Marcelo [1 ]
机构
[1] Univ Northern Parana, Ctr Res Hlth Sci, Rua Ildefonso Werner 177, BR-86055545 Condominio Royal Golf, Londrina, Brazil
关键词
Fat-free mass; Body fat; Body fat percentage; Measurement bias; Validity; BIOIMPEDANCE SPECTROSCOPY; VOLUMES; FAT; VALIDATION; AGREEMENT; POSITION; BIPOLAR; MODEL; MASS;
D O I
10.20960/nh.2376
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Introduction: recently there have been several new versions of equipment based on the principles of bioelectrical impedance (BIA). Therefore, it is important to know the agreement between data produced by different commercially available equipment. Objective: to verify the agreement between fat-free mass (FFM), fat mass (FM), and body fat percentage (BF%) estimated using different segmental multi-frequency BIA (Tanita (R) MC-980U and InBody 770 (R)) and whole-body spectral techniques (Xitron 4200). Methods: the sample consisted of 117 adults of both sexes, aged between 18 and 28 years. Methodological procedures followed specific guidelines for each equipment model. Agreement was analyzed by the t-test for paired data, concordance correlation coefficient (CCC), and Bland-Altman plot. Results: mean estimates of FFM, FM, and BF% produced by the Tanita (R) MC-980U and InBody 770 (R) devices did not present statistical differences compared to the Xitron 4200 (R) reference device. CCC values for FFM demonstrated magnitudes between 0.904 and 0.931, representing clinically acceptable strength of agreement, while for FM and BF% the strength of agreements was weak (< 0.90). Regarding the FFM, the bias showed underestimates of -0.98 kg to -1.69 kg, with limits of agreement between -7.32 kg and 3.94 kg. In the case of FM and BF%, overestimations were observed that reached values of 1.01 kg and 0.71%, with limits of agreement of -1.91 kg to 3.93 kg and -3.86% to 5.28%, respectively. Conclusion: FFM, FM, and BF% estimated by the Tanita (R) MC-980U and InBody 770 (R) devices were not individually comparable with estimates produced by the Xitron 4200 (R) reference device; therefore, its replacement for diagnostic purposes and inter-or intra-subject comparisons is not recommended.
引用
收藏
页码:618 / 625
页数:8
相关论文
共 50 条
  • [1] Comparison of Air Displacement Plethysmography and Multi-Frequency Bioelectrical Impedance Analysis for Body Composition Assessment
    Gordon, Benjamin T.
    Arikawa, Andrea Y.
    Gerkens, Kristin
    Gonzalez, Andriana
    Boyd, Sara
    Baskin, Amber
    Bednarzyk, Michele
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 907 - 907
  • [2] Accuracy of Multi-frequency Bioelectrical Impedance to Determine Segmental Lean Body Mass in Young Women
    Miller, Daniel R.
    Masteller, Brittany
    Dixon, Curt B.
    Andreacci, Joseph L.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 618 - 618
  • [3] Validation Of Multi-frequency Bioelectrical Impedance Analysis For The Assessment Of Body Composition In Children
    Andreacci, Joseph L.
    Fetterman, Meghan
    Masteller, Brittany
    Dixon, Curt B.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 612 - 612
  • [4] Evaluation of multi-frequency bioelectrical impedance analysis for the assessment of body composition in individuals with obesity
    Sullivan, P. A.
    Still, C. D.
    Jamieson, S. T.
    Dixon, C. B.
    Irving, B. A.
    Andreacci, J. L.
    [J]. OBESITY SCIENCE & PRACTICE, 2019, 5 (02): : 141 - 147
  • [5] Direct Segmental Multi-Frequency Bioelectrical Impedance Analysis Is Useful to Evaluate Sarcopenia
    Kaido, T.
    Uemoto, S.
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2013, 13 (09) : 2506 - 2507
  • [6] A comparison of single- and multi-frequency bioelectrical impedance methods to assess human body composition
    Ohkawara, K
    Tanaka, K
    Nakata, Y
    Lee, DJ
    Wee, SW
    Nakadomo, F
    [J]. JAPANESE JOURNAL OF PHYSICAL FITNESS AND SPORTS MEDICINE, 2003, 52 (04) : 443 - 453
  • [7] Body composition: validity of segmental bioelectrical impedance analysis
    LaForgia, Joe
    Gunn, Simon M.
    Withers, Robert T.
    [J]. ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION, 2008, 17 (04) : 586 - 591
  • [8] Body Composition Analysis in Critically Ill Survivors: A Comparison of Bioelectrical Impedance Spectroscopy Devices
    Baldwin, Claire E.
    Paratz, Jennifer D.
    Bersten, Andrew D.
    [J]. JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2012, 36 (03) : 306 - 315
  • [9] Body composition measured by multi-frequency bioelectrical impedance following creatine supplementation
    Buck, Emily A.
    Saunders, Michael J.
    Edwards, Elizabeth S.
    Womack, Christopher J.
    [J]. JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2023, 63 (11): : 1188 - 1193
  • [10] Characteristics of body water distribution in healthy adults measured by multi-frequency bioelectrical impedance analysis
    Ando, Makoto
    Shimada, Noriaki
    Asano, Kenichiro
    Kikutsuji, Toru
    Ono, Jun-Ichi
    Jikuya, Kazuaki
    Mochizuki, Seiichi
    [J]. Journal of Biorheology, 2019, 33 (01) : 13 - 20