Electrochemical detection of NOx gas based on disposable paper-based analytical device using a copper nanoparticles-modified screen-printed graphene electrode

被引:28
|
作者
Pungjunun, Kingkan [1 ]
Chaiyo, Sudkate [1 ,2 ]
Praphairaksit, Narong [1 ]
Siangproh, Weena [3 ]
Ortner, Astrid [4 ]
Kalcher, Kurt [5 ]
Chailapakul, Orawon [1 ,6 ]
Mehmeti, Eda [5 ]
机构
[1] Chulalongkorn Univ, Fac Sci, Dept Chem, EOSCE, 254 Phayathai Rd, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Inst Biotechnol & Genet Engn, Bangkok 10330, Thailand
[3] Srinakharinwirot Univ, Fac Sci, Dept Chem, Sukhumvit 23, Bangkok 10110, Thailand
[4] Karl Franzens Univ Graz, Inst Pharmaceut Sci, Schubertstr 1, A-8010 Graz, Austria
[5] Karl Franzens Univ Graz, Inst Chem, Univ Pl 1, A-8010 Graz, Austria
[6] Chulalongkorn Univ, Nanotec CU Ctr Excellence Food & Agr, Bangkok 10330, Thailand
来源
关键词
Gas sensing; Differential pulse voltammetry; Nitric oxide; Nitrogen dioxide; NOx gas; ACTIVATED CARBON; NITRIC-OXIDE; SENSOR; PERFORMANCE; REMOVAL; GLUCOSE;
D O I
10.1016/j.bios.2019.111606
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A disposable gas-sensing paper-based device (gPAD) was fabricated in origami design which integrates the gas adsorbent and the electrochemical detection zone in a single device. The gPAD for the determination of NOx gas uses a screen-printed graphene electrode modified with copper nanoparticles (CuNP/SPGE) to achieve high sensitivity and selectivity. The gPAD detects both, NO and NO2 (as NOx) with same current responses. The measurement could be performed directly through differential pulse voltammetry (DPV) with a detection limit as low as 0.23 vppm and 0.03 vppm with exposure times of 25 min and 1 h, respectively. The reproducibility in terms of relative standard deviation was less than 5.1% (n = 7 devices) at 25, 75 and 125 vppm NO2 and the lifetime of this device was more than 30 days. The gPAD was applied to detect NOx in air and exhaust gases from cars. In comparison with spectrophotometry, there are no significant differences between both methods using a paired t-test of the results on a 95% confidence level. The designed gPAD can provide a new template model for other gas sensors with features of disposability and portability for fieldwork analysis at low cost.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Screen-printed microfluidic paper-based analytical device (μPAD) as a barcode sensor for magnesium detection using rubber latex waste as a novel hydrophobic reagent
    Jarujamrus, Purim
    Meelapsom, Rattapol
    Naksen, Puttharaksa
    Ditcharoen, Nadh
    Anutrasakda, Wipark
    Siripinyanond, Atitaya
    Amatatongchai, Maliwan
    Supasorn, Saksri
    [J]. ANALYTICA CHIMICA ACTA, 2019, 1082 : 66 - 77
  • [42] Biosensors Based on Graphene Modified Screen-Printed Electrodes for The Detection of Catecholamines
    Apetrei, I. M.
    Popa , C. V.
    Apetrei, C.
    Tutunaru, D.
    [J]. ROMANIAN BIOTECHNOLOGICAL LETTERS, 2014, 19 (05): : 9801 - 9809
  • [43] A novel screen-printed microfluidic paper-based electrochemical device for detection of glucose and uric acid in urine (vol 18, 92, 2016)
    Yao, Yong
    Zhang, Chunsun
    [J]. BIOMEDICAL MICRODEVICES, 2022, 24 (03)
  • [44] A novel disposable electrochemical sensor for determination of carbamazepine based on Fe doped SnO2 nanoparticles modified screen-printed carbon electrode
    Lavanya, N.
    Sekar, C.
    Ficarra, S.
    Tellone, E.
    Bonavita, A.
    Leonardi, S. G.
    Neri, G.
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 62 : 53 - 60
  • [45] Disposable L-lactate biosensor based on a screen-printed carbon electrode enhanced by graphene
    Tu, Dandan
    He, Yu
    Rong, Yuanzhen
    Wang, You
    Li, Guang
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (04)
  • [46] Electrochemical Affinity Biosensors Based on Disposable Screen-Printed Electrodes for Detection of Food Allergens
    Vasilescu, Alina
    Nunes, Gilvanda
    Hayat, Akhtar
    Latif, Usman
    Marty, Jean-Louis
    [J]. SENSORS, 2016, 16 (11)
  • [47] Sensitive electrochemical sensor based on nickel/PDDA/reduced graphene oxide modified screen-printed carbon electrode for nitrite detection
    Paisanpisuttisin, Aunyarut
    Poonwattanapong, Praewpitcha
    Rakthabut, Punnada
    Ariyasantichai, Paranee
    Prasittichai, Chaiya
    Siriwatcharapiboon, Wilai
    [J]. RSC ADVANCES, 2022, 12 (45) : 29491 - 29502
  • [48] Simultaneous Detection of Morphine and Diclofenac Using Graphene Nanoribbon Modified Screen-Printed Electrode
    Jahani, Peyman Mohamadzadeh
    Mohammadi, Sayed Zia
    Khodabakhshzadeh, Ali
    Cha, Joo Hwan
    Asl, Mehdi Shahedi
    Shokouhimehr, Mohammadreza
    Zhang, Kaiqiang
    Quyet Van Le
    Peng, Wanxi
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (09): : 9037 - 9048
  • [49] Aptasensor platform based on electrochemical Paper-Based analytical device for histamine detection
    Eksin, Ece
    Erdem, Arzum
    [J]. MICROCHEMICAL JOURNAL, 2024, 204
  • [50] Novel 3D Printed Microfluidic Paper-Based Analytical Device With Integrated Screen-Printed Electrodes for Automated Viscosity Measurements
    Puneeth, S. B.
    Goel, Sanket
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 2019, 66 (07) : 3196 - 3201