Closed-loop identification with an unstable or nonminimum phase controller

被引:20
|
作者
Codrons, B
Anderson, BDO
Gevers, M
机构
[1] Univ Catholique Louvain, CESAME, B-1348 Louvain, Belgium
[2] Laborelec SC, Prod Line Proc Control, B-1630 Linkebeek, Belgium
[3] Australian Natl Univ, Res Sch Informat Sci & Engn, Canberra, ACT 0200, Australia
关键词
closed-loop identification; internal stability; ustable or nonminimurn phase controller; control design;
D O I
10.1016/S0005-1098(02)00137-1
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In many practical cases, the identification of a system is done in closed loop with some controller. In this paper, we show that the internal stability of the resulting model, in closed loop with the same controller, is not always guaranteed if this controller is unstable and/or nonminimum phase, and that the classical closed-loop prediction-error identification methods present different properties regarding this stability issue. With some of these methods, closed-loop instability of the identified model is actually guaranteed. This is a serious drawback if this model is to be used for the design of a new controller. We give guidelines to avoid the emergence of this instability problem; these guidelines concern both the experiment design and the choice of the identification method. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2127 / 2137
页数:11
相关论文
共 50 条
  • [21] Closed-Loop Identification Applied to a DC Servomechanism: Controller Gains Analysis
    Miranda Colorado, Roger
    Contreras Castro, Gamaliel
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2013, 2013
  • [22] Controller order reduction by identification in closed-loop applied to a benchmark problem
    Constantinescu, A
    Landau, ID
    EUROPEAN JOURNAL OF CONTROL, 2003, 9 (01) : 84 - 99
  • [23] Closed-loop on-line process identification using a proportional controller
    Park, JH
    Park, HI
    Lee, IB
    CHEMICAL ENGINEERING SCIENCE, 1998, 53 (09) : 1713 - 1724
  • [24] Closed-loop disturbance identification and controller tuning for discrete manufacturing processes
    Del Castillo, E
    TECHNOMETRICS, 2002, 44 (02) : 134 - 141
  • [25] Closed-loop subspace identification
    University of Alberta, Edmonton, AB, Canada
    不详
    Lect. Notes Control Inf. Sci., 2008, (55-78):
  • [26] Closed-loop identification with a quantizer
    Wang, M
    Thornhill, NF
    Huang, B
    JOURNAL OF PROCESS CONTROL, 2005, 15 (06) : 729 - 740
  • [27] Closed-Loop Control of an Unstable Open Cavity
    Sipp, Denis
    Barbagallo, Alexandre
    Schmid, Peter
    ACTIVE FLOW CONTROL II, 2010, 108 : 275 - +
  • [28] Closed-loop identification revisited
    Forssell, U
    Ljung, L
    AUTOMATICA, 1999, 35 (07) : 1215 - 1241
  • [29] An experimental study on the closed-loop system identification by observer/controller identification(OCID) algorithm
    Park, MS
    Yang, DH
    Park, DG
    Hong, SK
    CCA 2003: PROCEEDINGS OF 2003 IEEE CONFERENCE ON CONTROL APPLICATIONS, VOLS 1 AND 2, 2003, : 37 - 42
  • [30] On the Controller effect in Closed-Loop Identification for DC Servomechanisms under PD control
    Miranda, R.
    Garrido, R.
    Ortiz-Moctezuma, M. B.
    2011 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2011,