Advanced field shimming technology to reduce the influence of a screening current in a REBCO coil for a high-resolution NMR magnet

被引:28
|
作者
Iguchi, S. [1 ,2 ]
Piao, R. [1 ,3 ]
Hamada, M. [4 ]
Matsumoto, S. [5 ]
Suematsu, H. [6 ]
Takao, T. [2 ]
Saito, A. T. [3 ]
Li, J. [3 ]
Nakagome, H. [3 ]
Jin, X. [1 ]
Takahashi, M. [1 ]
Maeda, H. [1 ]
Yanagisawa, Y. [1 ,3 ]
机构
[1] RIKEN, Ctr Life Sci Technol, Yokohama, Kanagawa 2300045, Japan
[2] Sophia Univ, Fac Sci & Technol, Yotsuya 1028554, Japan
[3] Chiba Univ, Grad Sch Engn, Chiba 2368522, Japan
[4] Japan Superconductor Technol Inc, Kobe, Hyogo 6512271, Japan
[5] Natl Inst Mat Sci, Sperconducting Wire Unit, Tsukuba, Ibaraki 3050003, Japan
[6] JEOL RESONANCE Inc, Akishima, Tokyo 1968558, Japan
来源
SUPERCONDUCTOR SCIENCE & TECHNOLOGY | 2016年 / 29卷 / 04期
基金
日本科学技术振兴机构;
关键词
compact super-high field NMR; high-resolution NMR; REBCO coil; field inhomogeneity; screening current; shimming; ferromagnetic shim; 400 MHZ NMR; 1; GHZ; OPERATION;
D O I
10.1088/0953-2048/29/4/045013
中图分类号
O59 [应用物理学];
学科分类号
摘要
This paper describes a field shimming technology to obtain a spatially homogeneous magnetic field required for a high-resolution nuclear magnetic resonance (NMR) magnet under the influence of a screening current in a (RE) Ba2Cu3O7-x (REBCO) coil. Use of REBCO inner coils is one solution to realize a super-high field (>23.5 T, 1 GHz) NMR magnet. However, a REBCO coil generates a large amount of field error harmonics due to the inhomogeneous coil winding introduced by a thin tape conductor. In addition, the performance of a field correction coil and outer superconducting (SC) shim coils are significantly reduced due to the shielding effect of the screening current in the REBCO coil. Therefore, conventional shimming technology using SC shim coils and room temperature shim coils cannot adequately compensate those field error harmonics and high-resolution NMR measurements are not possible. In the present paper, an advanced field shimming technology including an inner SC shim coil and a novel type of ferromagnetic shim were installed in a 400 MHz low-temperature SC/REBCO NMR magnet. The inner SC shim coil and the ferromagnetic shim compensated for the reduction in the performances of the field correction coil and the SC shim coils, respectively. The field error harmonics were greatly compensated with the technology and a high NMR resolution <0.01 ppm was obtained. The results from the present work suggest an optimal shimming procedure for a super-high field NMR magnet with high-temperature superconductors inner coils, i.e. the best mix of shims.
引用
收藏
页数:12
相关论文
共 12 条
  • [1] 3-D Field Mapping and Active Shimming of a Screening-Current-Induced Field in an HTS Coil Using Harmonic Analysis for High-Resolution NMR Magnets
    Ahn, Min Cheol
    Hahn, Seungyong
    Lee, Haigun
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [2] An analytical approach towards passive ferromagnetic shimming design for a high-resolution NMR magnet
    Li, Frank X.
    Voccio, John P.
    Ahn, Min Cheol
    Hahn, Seungyong
    Bascun, Juan
    Iwasa, Yukikazu
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2015, 28 (07):
  • [3] Field stabilization for high-resolution solid state NMR magnet with external field-lock
    Shinagawa, Hideyuki
    Fujito, Teruaki
    Ohki, Shinobu
    Shimizu, Tadashi
    BUNSEKI KAGAKU, 2008, 57 (01) : 55 - 59
  • [4] Numerical Evaluation on Irregular Field Generated by Screening Current in High-Field REBCO Coil for Whole-Body MRI
    Nakazono, Kohei
    Ueda, Hiroshi
    Ishiyama, Atsushi
    Noguchi, So
    Miyazaki, Hiroshi
    Tosaka, Taizo
    Kurusu, Tsutomu
    Nomura, Shunji
    Urayama, Shinichi
    Fukuyama, Hidenao
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [5] OPTIMIZED SHIMMING FOR HIGH-RESOLUTION NMR USING 3-DIMENSIONAL IMAGE-BASED FIELD-MAPPING
    VANZIJL, PCM
    SUKUMAR, S
    JOHNSON, MO
    WEBB, P
    HURD, RE
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1994, 111 (02) : 203 - 207
  • [6] Influence of Preexcitation, High Temperature Magnetization and Combined Excitation Method on Screening Current Attenuation in Conduction-Cooled REBCO Coil
    Nagasaki, Yoh
    Miyazaki, Jun
    Kanamaru, Masatoshi
    Miyagi, Daisuke
    Tsuda, Makoto
    Miura, Hideaki
    Yokoyama, Shoichi
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2020, 30 (05)
  • [7] Design of a high-resolution programmable current source for coil-magnet actuators in a monolithic x-ray interferometric calibrator
    Dyer, DC
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (07) : 804 - 813
  • [8] Influence of Excitation Sequences on Screening-Current Induced Strain in a 36 T Ultra-High-Field Magnet: Numerical Analysis and Discussion
    Shao, Liangjun
    Song, Peng
    Yan, Yufan
    Zhang, Xintao
    Liu, Huajun
    Liu, Fang
    Qu, Timing
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (03) : 1 - 5
  • [9] Combination of high hoop stress tolerance and a small screening current-induced field for an advanced Bi-2223 conductor coil at 4.2K in an external field
    Yanagisawa, Y.
    Xu, Y.
    Iguchi, S.
    Hamada, M.
    Matsumoto, S.
    Nishijima, G.
    Nakagome, H.
    Takao, T.
    Suematsu, H.
    Oshima, Y.
    Jin, X.
    Takahashi, M.
    Maeda, H.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2015, 28 (12):
  • [10] A Field-Shaking System to Reduce the Screening-Current-Induced Field in the 800-MHz HTS Insert of the MIT 1.3-GHz LTS/HTS NMR Magnet: A Small-Model Study
    Lee, Jiho
    Park, Dongkeun
    Michael, Philip C.
    Noguchi, So
    Bascunan, Juan
    Iwasa, Yukikazu
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (03)