3-D Field Mapping and Active Shimming of a Screening-Current-Induced Field in an HTS Coil Using Harmonic Analysis for High-Resolution NMR Magnets

被引:20
|
作者
Ahn, Min Cheol [1 ]
Hahn, Seungyong [2 ]
Lee, Haigun [3 ]
机构
[1] Kunsan Natl Univ, Dept Elect Engn, Gunsan, Jeonbuk, South Korea
[2] MIT, Francis Bitter Magnet Lab, Cambridge, MA 02139 USA
[3] Korea Univ, Dept Mat Sci & Engn, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Active shimming; harmonic analysis; screening-current-induced field; 3-D field mapping;
D O I
10.1109/TASC.2012.2237491
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A screening-current-induced field (SCF) in a superconducting magnet is now considered as one of the major technical challenges for HTS (high-temperature superconducting) magnets, particularly wound with tape-shape conductors such as Bi2223 and YBCO, to be used for NMR (nuclear magnetic resonance) applications where a ppb (part-per-billion) level of field homogeneity is required. To date, many attempts to characterize the SCF and minimize its impact on field homogeneity have been undertaken, but it is still one of bottlenecks for HTS NMR magnets. In general, magnetic fields generated by an NMR magnet are expressed by the spatial harmonics in order to systematically characterize the field errors and obtain a target field homogeneity by shimming. Thus, it is important to analyze the spatial harmonics of the SCF in an HTS magnet for its application to a high-resolution NMR device. In this paper, magnetic fields of an HTS coil were measured within a target space using an in-house 3-D field mapper, and their spatial harmonics were obtained using associated Legendre equations. Also, the temporal behavior of the SCF was investigated by continuous field mappings and their analyses. Finally, a radial shim coil, ZY, was designed, constructed, and operated with the HTS test coil, and the hysteresis and the temporal behavior of the SCF during shimming were also studied. With a shim coil current, the ZY gradient of the SCF was reduced by 70%.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Advanced field shimming technology to reduce the influence of a screening current in a REBCO coil for a high-resolution NMR magnet
    Iguchi, S.
    Piao, R.
    Hamada, M.
    Matsumoto, S.
    Suematsu, H.
    Takao, T.
    Saito, A. T.
    Li, J.
    Nakagome, H.
    Jin, X.
    Takahashi, M.
    Maeda, H.
    Yanagisawa, Y.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2016, 29 (04):
  • [2] Experimental Study on Hysteresis of Screening-Current-Induced Field in an HTS Magnet for NMR Applications
    Ahn, Min Cheol
    Jang, Jeongwoo
    Lee, Woo Seung
    Hahn, Seungyong
    Lee, Haigun
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (03)
  • [3] Field mapping, NMR lineshape, and screening currents induced field analyses for homogeneity improvement in LTS/HTS NMR magnets
    Hahn, Seung-yong
    Bascunan, Juan
    Kim, Woo-Seok
    Bobrov, Emanuel S.
    Lee, Haigun
    Iwasa, Yukikazu
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) : 856 - 859
  • [4] OPTIMIZED SHIMMING FOR HIGH-RESOLUTION NMR USING 3-DIMENSIONAL IMAGE-BASED FIELD-MAPPING
    VANZIJL, PCM
    SUKUMAR, S
    JOHNSON, MO
    WEBB, P
    HURD, RE
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1994, 111 (02) : 203 - 207
  • [5] Study on elimination of screening-current-induced field in pancake-type non-insulated HTS coil
    Kim, K. L.
    Song, J. B.
    Yang, D. G.
    Kim, Y. G.
    Kim, T. H.
    Kim, S. K.
    Park, M. W.
    Lee, H. G.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2016, 29 (03):
  • [6] Screening-Current-Induced Magnetic Field of Conduction-Cooled HTS Magnets Wound With REBCO-Coated Conductors
    Miyazaki, Hiroshi
    Iwai, Sadanori
    Uto, Tatsuro
    Otani, Yasumi
    Takahashi, Masahiko
    Tosaka, Taizo
    Tasaki, Kenji
    Nomura, Shunji
    Kurusu, Tsutomu
    Ueda, Hiroshi
    Noguchi, So
    Ishiyama, Atsushi
    Urayama, Shin-Ichi
    Fukuyama, Hidenao
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [7] High-resolution NMR with resistive and hybrid magnets: Deconvolution using a field-fluctuation signal
    Iijima, Takahiro
    Takegoshi, K.
    Hashi, Kenjiro
    Fujito, Teruaki
    Shimizu, Tadashi
    JOURNAL OF MAGNETIC RESONANCE, 2007, 184 (02) : 258 - 262
  • [8] 3-D Analytical Magnetic Field Analysis of the Eddy Current Coupling With Halbach Magnets
    Jin, Ping
    Tian, Yu
    Lu, Yi
    Guo, Yujing
    Lei, Gang
    Zhu, Jianguo
    IEEE TRANSACTIONS ON MAGNETICS, 2020, 56 (01)
  • [9] A Field-Shaking System to Reduce the Screening-Current-Induced Field in the 800-MHz HTS Insert of the MIT 1.3-GHz LTS/HTS NMR Magnet: A Small-Model Study
    Lee, Jiho
    Park, Dongkeun
    Michael, Philip C.
    Noguchi, So
    Bascunan, Juan
    Iwasa, Yukikazu
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (03)
  • [10] Active-amplifier-array diagnostics using high-resolution electrooptic field mapping
    Yang, KY
    Marshall, T
    Forman, M
    Hubert, J
    Mirth, L
    Popovic, Z
    Katehi, LPB
    Whitaker, JF
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2001, 49 (05) : 849 - 857