Sensitivity Analysis for a Guarded-Hot-Plate Apparatus: A Methodology Based on Orthogonal Experiment Designs

被引:0
|
作者
Zarr, Robert R. [1 ]
Filliben, James J. [2 ]
机构
[1] NIST, Engn Lab, Gaithersburg, MD 20899 USA
[2] NIST, Informat Technol Lab, Gaithersburg, MD 20899 USA
关键词
experimental design; fractional factorial; full factorial; guarded hot plate; fibrous glass board; orthogonal; ruggedness; sensitivity; thermal conductivity; thermal insulation;
D O I
10.1520/JTE20140287
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Results and analyses of a sensitivity study of six controlled variables on the response of the National Institute of Standards and Technology (NIST) 500mm guarded-hot-plate apparatus are presented. The effects of four factors held constant as well as three uncontrolled environmental variables were also examined. The goal of the study is to derive a sensitivity analysis ranking of the relative importance of factors and interactions affecting the apparatus. Sixty-six thermal conductivity measurements were conducted across three experiments at a mean temperature of 310 K for a pair of fibrous-glass specimens (120 kg.m(-3)) having nominal dimensions 500mm in diameter and 26mm in thickness. The apparatus response was studied using an orthogonal fractional factorial design, a one-factor-at-a-time design, and a full factorial design for a subset of factors from the fractionated design. The results indicate that most important factor affecting the thermal conductivity measurement was the temperature difference across the air space separating the central meter plate and the surrounding guard plate, described here as the gap temperature difference (Delta T-g). The study also revealed an interaction between the gap temperature difference and the temperature difference across the specimen (Delta T-avg). An empirical model for the results of the sensitivity study is presented. Results of the gap temperature difference (Delta T-g) are similar to published results from another guarded-hot-plate apparatus. Improvements for equipment operation, as well as insights to the sources of experimental uncertainty, are presented.
引用
收藏
页码:102 / 120
页数:19
相关论文
共 50 条
  • [41] Influence of Thermal Contact Resistance on Thermal Conductivity Measurement with a High-Temperature Guarded Hot Plate Apparatus
    Kai Yao
    Yunchuan Liu
    Yanping Zhou
    Xuerong Wang
    Qianqian Wang
    Yandong Ma
    Cui Yao
    International Journal of Thermophysics, 2020, 41
  • [42] Influence of Thermal Contact Resistance on Thermal Conductivity Measurement with a High-Temperature Guarded Hot Plate Apparatus
    Yao, Kai
    Liu, Yunchuan
    Zhou, Yanping
    Wang, Xuerong
    Wang, Qianqian
    Ma, Yandong
    Yao, Cui
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2020, 41 (02)
  • [43] Measuring the Specific Heat Capacity of Thermal Insulation Materials Used in Buildings by Means of a Guarded Hot Plate Apparatus
    Wakili, Karim Ghazi
    Raedle, Wolfgang
    Rohner, Thomas
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2023, 44 (01)
  • [44] Investigations on design and construction of a square guarded hot plate (SGHP) apparatus for thermal conductivity measurement of insulation materials
    Reddy, K. S.
    Jayachandran, S.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2017, 120 : 136 - 147
  • [45] Sensitivity Analysis and Experimental Verification of Bolt Support Parameters Based on Orthogonal Experiment
    Zhang, Kun
    Su, Jinpeng
    Liu, Zengkai
    Chen, Hongyue
    Zhang, Qiang
    Sun, Shaoan
    SHOCK AND VIBRATION, 2020, 2020 (2020)
  • [46] Sensitivity analysis of controlling factors on failure depth of floor based on orthogonal experiment
    Liu, Wei-Tao
    Liu, Shi-Liang
    Ji, Bao-Jing
    Meitan Xuebao/Journal of the China Coal Society, 2015, 40 (09): : 1995 - 2001
  • [47] THERMAL-CONDUCTIVITY OF A WIDE-RANGE OF ALTERNATIVE REFRIGERANTS MEASURED WITH AN IMPROVED GUARDED HOT-PLATE APPARATUS
    HAMMERSCHMIDT, U
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1995, 16 (05) : 1203 - 1211
  • [48] Global Comprehensive Sensitivity Analysis of Arch Dam Construction Parameters Based on Orthogonal Experiment
    Denghua Zhong
    Zhiqiang Chu
    Bingyu Ren
    Mengqi Zhao
    Tao Guan
    Wenshuai Song
    Transactions of Tianjin University, 2017, (05) : 427 - 433
  • [49] Global Comprehensive Sensitivity Analysis of Arch Dam Construction Parameters Based on Orthogonal Experiment
    Denghua Zhong
    Zhiqiang Chu
    Bingyu Ren
    Mengqi Zhao
    Tao Guan
    Wenshuai Song
    Transactions of Tianjin University, 2017, 23 (05) : 427 - 433
  • [50] Sensitivity analysis of heat dissipation factors in a hot oil pipeline based on orthogonal experiments
    Xu, Ying
    Nie, Xin
    Liu, Xiao-Yan
    Cheng, Qinglin
    Liu, Yang
    Dai, Zhonghua
    SCIENCE PROGRESS, 2020, 103 (01)