Performance Analysis of a Overhead Power Transmission Line Tower Using Polymer Composite Material

被引:18
|
作者
Selvaraj, M. [1 ]
Kulkarni, S. M. [2 ]
Rameshbabu, R. [1 ]
机构
[1] Cent Power Res Inst, Sir CV Raman Rd, Bangalore 560080, Karnataka, India
[2] Natl Inst Technol Karnataka, Mangalore 575025, India
关键词
Composite materials; Materials testing; Transmission lines; Towers;
D O I
10.1016/j.mspro.2014.07.451
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For technical, aesthetic and economic reasons, our next generation overhead power transmission lines will be built with new materials and new design concepts in order to reduce the dimensions of the support structures. This paper discusses the mechanical performance tests carried out on a 66 kV overhead power transmission line tower built with Fiber Reinforced Polymer (FRP) composite material for the first time in India. The details of development of composite tower and its performance during full scale test carried out at Central Power Research Institute (CPRI) Bangalore, India are presented (C) 2014 Elsevier Ltd.
引用
收藏
页码:1340 / 1348
页数:9
相关论文
共 50 条
  • [21] Lightning Surge Analysis of a Transmission Line Tower With an XLPE Power Cable and Metallic Cleats Using the FDTD Method
    Tatematsu, Akiyoshi
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2020, 62 (05) : 1796 - 1806
  • [22] Backflashover analysis of overhead transmission lines for different tower and lightning models
    Teixeira, CJC
    Pinto, JAD
    UPEC 2004: 39TH INTERNATIONAL UNIVERSITITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2005, : 238 - 241
  • [23] Influence of wind vibration of overhead transmission tower-line system on ice shedding
    Zhang, R. (zhangrufang@cqu.edu.cn), 1600, Science Press (40):
  • [24] Review on analysis and design of lattice steel structure of overhead transmission tower
    Kamarudin, Siti Aisyah
    Usman, Fathoni
    Baharuddin, Intan Nor Zuliana
    INTERNATIONAL JOURNAL OF ADVANCED AND APPLIED SCIENCES, 2018, 5 (01): : 73 - 80
  • [25] Simulation of the electromagnetic field in the vicinity of the overhead power transmission line
    Ayad A.N.E.I.
    Krika W.
    Boudjella H.
    Benhamida F.
    Horch A.
    European Journal of Electrical Engineering, 2019, 21 (01) : 49 - 53
  • [26] Design and Implementation of Power Line Sensornet for Overhead Transmission Lines
    Yang, Yi
    Divan, Deepak
    Harley, Ronald G.
    Habetler, Thomas G.
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 4045 - 4052
  • [28] Applications of an Algorithm for Overhead Power Line Analysis
    Vilacha Perez, Carlos
    Fernandez Otero, Antonio
    Moreira Meira, Julio Cezar
    Miguez Garcia, Edelmiro
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (11A):
  • [29] Calculation and analysis of ampacity and stress of overhead transmission line
    Li, Junhui
    Jia, Siqi
    Wu, Peng
    Du, Dongmei
    He, Qing
    AIP ADVANCES, 2022, 12 (10)
  • [30] Overhead Transmission Line Thermographic Inspection Using a Drone
    Taqi, Ali
    Beryozkina, Svetlana
    2019 IEEE 10TH GCC CONFERENCE & EXHIBITION (GCC), 2019,