Single-center retrospective review of early outcomes of radiofrequency ablation versus cyanoacrylate ablation of isolated great saphenous vein insufficiency

被引:19
|
作者
Bademci, Mehmet Senel [1 ]
Kocaaslan, Cemal [1 ]
Aldag, Mustafa [1 ]
Yalvac, Emine Seyma Denli [1 ]
Oztekin, Ahmet [1 ]
Bulut, Nurgul [2 ]
Aydin, Ebuzer [1 ]
机构
[1] Istanbul Medeniyet Univ, Goztepe Training & Res Hosp, Dept Cardiovasc Surg, Med Fac, Dr Erkin St 12, TR-34722 Istanbul, Turkey
[2] Istanbul Medeniyet Univ, Dept Biostat, Med Fac, Istanbul, Turkey
关键词
Great saphenous vein; Cyanoacrylate closure; Radiofrequency ablation; Varicose vein;
D O I
10.1016/j.jvsv.2018.12.017
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Data comparing radiofrequency ablation (RFA) with cyanoacrylate closure (CAC) treatment of isolated great saphenous vein (GSV) insufficiency are limited. In this study, we present our early outcomes of RFA vs CAC for the treatment of GSV insufficiency. Methods: Between March 2015 and February 2017, a total of 159 patients underwent CAC (n = 75) or RFA (n = 84) for treatment of GSV insufficiency by a single surgeon. Medical data of the patients were retrieved from the institutional database and retrospectively analyzed. All patients underwent lower extremity venous color duplex ultrasound examination. The Venous Clinical Severity Score and Aberdeen Varicose Vein Questionnaire were used. Total closure rates of the GSV with RFA or CAC were recorded at 1 month, 6 months, and 12 months. Procedure-related adverse events and quality of life of the patients were also evaluated. Results: The mean age was 46.33 +/- 14.40 years in the CAC group and 48.09 +/- 13.25 years in the RFA group (P = .4). The mean treated saphenous vein diameter was 7 mm in the CAC group and 7.25 mm in the RFA group (P = .07). The length of treated venous segment was 30 cm in both the CAC and RFA groups (P = .66). The mean duration of operation was 25 minutes in the CAC group and 35 minutes in the RFA group (P < .001). The incidence of adverse events was higher in the RFA group (P < .05). At 1 month, 6 months, and 12 months of follow-up, there was no statistically significant difference in the total closure rates between the CAC and RFA groups. There was no significant difference in the Venous Clinical Severity Score and Aberdeen Varicose Vein Questionnaire score between the groups (P > .05). Conclusions: Our study results suggest that both RFA and CAC are effective in closure of the target GSV. Although the incidence of tumescent anesthesia-related and procedure-related complications is higher with the RFA technique, both techniques can be used safely with similar success rate and patient satisfaction.
引用
收藏
页码:480 / 485
页数:6
相关论文
共 50 条
  • [11] Comparative outcomes of radiofrequency endoluminal ablation, invagination stripping, and cryostripping in the treatment of great saphenous vein insufficiency
    Stötter, L
    Schaaf, I
    Bockelbrink, A
    PHLEBOLOGY, 2006, 21 (02) : 60 - 64
  • [12] Selective crossectomy combined with mechanochemical ablation in the treatment of great saphenous vein insufficiency: Early results of a single center experience
    Petrone, Anna
    Peluso, Antonio
    Ammollo, Raffaele P.
    Turchino, Davide
    Del Guercio, Luca
    Andreucci, Michele
    Serra, Raffaele
    Bracale, Umberto M.
    PHLEBOLOGY, 2022, 37 (07) : 522 - 528
  • [13] A Comparison of 1470-nm Endovenous Laser Ablation and Radiofrequency Ablation in the Treatment of Great and Small Saphenous Vein Insufficiency
    Torma, Norbert
    Sihotsky, Vladimir
    Kopolovets, Ivan
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (05) : E127 - E128
  • [14] VeClose trial 12-month outcomes of cyanoacrylate closure versus radiofrequency ablation for incompetent great saphenous veins
    Morrison, Nick
    Gibson, Kathleen
    Vasquez, Michael
    Weiss, Robert
    Cher, Daniel
    Madsen, Monte
    Jones, Andrew
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2017, 5 (03) : 321 - 330
  • [15] A longitudinal single-center cohort study on the prevalence and risk of accessory saphenous vein reflux after radiofrequency segmental thermal ablation of great saphenous veins
    Proebstle, Thomas M.
    Moehler, Thomas
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2015, 3 (03) : 265 - 269
  • [16] Endovenous ablation with laser for great saphenous vein insufficiency and tributary varices: A retrospective evaluation
    Lu, Xinwu
    Ye, Kaichuang
    Li, Weimin
    Lu, Min
    Huang, Xintian
    Jiang, Mier
    JOURNAL OF VASCULAR SURGERY, 2008, 48 (03) : 675 - 679
  • [17] Sonographic Evaluation of Venous Insufficiency and Sonography-Guided Radiofrequency Ablation of the Great Saphenous Vein
    Garrison, Kassandra L.
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2007, 23 (05) : 272 - 279
  • [18] Early experience with radiofrequency ablation of the greater saphenous vein
    Wagner, WH
    Levin, PM
    Cossman, DV
    Lauterbach, SR
    Cohen, JL
    Farber, A
    ANNALS OF VASCULAR SURGERY, 2004, 18 (01) : 42 - 47
  • [19] Cyanoacrylate Embolization versus Endovenous Laser Ablation in Treating Saphenous Vein Insufficiency: A Systematic Review and Meta-Analysis
    Amshar, Mohamed
    Nugraha, Raka Aldy
    Batubara, Edwin Adhi Darmawan
    Siddiq, Taofan
    Indriani, Suci
    Adiarto, Suko
    ANNALS OF VASCULAR SURGERY, 2022, 80 : 313 - 324
  • [20] Mechanochemical endovenous ablation for the treatment of great saphenous vein insufficiency
    van Eekeren, Ramon R. J. P.
    Boersma, Doeke
    Holewijn, Suzanne
    Werson, Debora A. B.
    de Vries, Jean Paul P. M.
    Reijnen, Michel M. J. P.
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2014, 2 (03) : 282 - 288