A reagentless optical biosensor based on the intrinsic absorption properties of peroxidase

被引:21
|
作者
Sanz, Vanesa [1 ]
de Marcos, Susana [1 ]
Galban, Javier [1 ]
机构
[1] Univ Zaragoza, Fac Sci, Dept Analyt Chem, INA,ABG, Zaragoza 50009, Spain
来源
BIOSENSORS & BIOELECTRONICS | 2007年 / 22卷 / 06期
关键词
reagentless biosensors; peroxidase intrinsic absorption; molecular absorption spectrometry; Kubelka-Munk revised theory;
D O I
10.1016/j.bios.2006.04.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
During the reversible reaction between peroxiclase (HRP) and H2O2, several peroxidase intermediate species, showing different molecular absorption spectra, are formed which can be used for H2O2 determination; when HO, is generated in a previous enzymatic reaction, the substrate involved in this reaction can also be determined. On this basis, a new family of fully reversible reagentless optical biosensors containing HRP is presented; glucose determination is used as a model. The biosensor (which can be used for at least 6 months and/or more than 750 measurements) is prepared by HRP and glucose oxidase entrapment in a polyacrylamide gel matrix. A mathematical model (in which optical, kinetic and transport aspects are considered) relating the measured absorbance with the substrate concentration is also presented together with a simple methodology for characterization of this kind of biosensor. Regarding the optical model, the Kubelka-Mulk theory of reflectance does not give good results and the biosensors are better described by the Rayleigh theory of polymer solutions. Under working conditions, linear response ranges from 1.5 x 10(-6) to 3.0 x 10(-4) M glucose and CV was about 4%. This biosensor has been applied for glucose determination in fruit juices and synthetic serum samples without sample pretreatment. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:956 / 964
页数:9
相关论文
共 50 条
  • [1] Reagentless optical biosensor
    Grace, KM
    Goeller, RM
    Grace, WK
    Kolar, JD
    Morrison, LJ
    Sweet, MR
    Wiig, LG
    Reed, SM
    Lauer, SA
    Little, KM
    Bustos, GL
    Anderson, AS
    Swanson, BI
    CHEMICAL AND BIOLOGICAL POINT SENSORS FOR HOMELAND DEFENSE, 2004, 5269 : 55 - 64
  • [2] Modelling a peroxidase-based optical biosensor
    Baronas, Romas
    Gaidamauskaite, Evelina
    Kulys, Juozas
    SENSORS, 2007, 7 (11): : 2723 - 2740
  • [3] A reagentless amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene green in a modified zeolite matrix
    Liu, BH
    Yan, F
    Kong, JL
    Deng, JQ
    ANALYTICA CHIMICA ACTA, 1999, 386 (1-2) : 31 - 39
  • [4] Reagentless chemiluminescence biosensor for determination of hydrogen peroxide based on the immobilization of horseradish peroxidase on biocompatible chitosan membrane
    Zhou, GJ
    Wang, G
    Xu, JJ
    Chen, HY
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 81 (2-3) : 334 - 339
  • [5] A reagentless electrochemical biosensor based on a protein scaffold
    Jhaveri, SD
    Mauro, JM
    Goldston, HM
    Schauer, CL
    Tender, LM
    Trammell, SA
    CHEMICAL COMMUNICATIONS, 2003, (03) : 338 - 339
  • [6] Dehydrogenase based reagentless biosensor for monitoring phenylketonuria
    Weiss, David J.
    Dorris, Megan
    Loh, Amanda
    Peterson, Laura
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11): : 2436 - 2441
  • [7] Optical fiber enzymatic biosensor for reagentless measurement of ethylene dibromide
    Reardon, Kenneth F.
    Campbell, Derek W.
    Mueller, Cord
    ENGINEERING IN LIFE SCIENCES, 2009, 9 (04): : 291 - 297
  • [8] Direct glucose determination in blood using a reagentless optical biosensor
    Sanz, Vanesa
    de Marcos, Susana
    Galban, Javier
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (12): : 2876 - 2883
  • [9] A reagentless bienzyme amperometric biosensor based on alcohol oxidase/peroxidase and an Os-complex modified electrodeposition paint
    Smutok, O
    Ngounou, B
    Pavlishko, H
    Gayda, G
    Gonchar, M
    Schuhmann, W
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) : 590 - 598
  • [10] Reagentless Aptamer Based Impedance Biosensor for Monitoring Adenosine
    Liu, Zhimin
    Li, Zhejian
    Shen, Guoli
    Yu, Ruqin
    ELECTROANALYSIS, 2009, 21 (16) : 1781 - 1785