Reagentless Aptamer Based Impedance Biosensor for Monitoring Adenosine

被引:12
|
作者
Liu, Zhimin [1 ]
Li, Zhejian [1 ]
Shen, Guoli [2 ]
Yu, Ruqin [2 ]
机构
[1] Henan Univ Technol, Coll Chem & Chem Engn, Zhengzhou 450052, Peoples R China
[2] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
关键词
Electrochemical impedance spectroscopy; Biosensors; Aptamers; nano-MnO2; Adenosine; HYDROGEN-PEROXIDE; LABEL-FREE; NANOPARTICLES; SENSORS;
D O I
10.1002/elan.200904599
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and highly sensitive electrochemical impedance spectroscopy (EIS) biosensor based on nano-MnO2 as a platform for the immobilization of the aptamer was developed for the determination of adenosine. In the measurement of adenosine, the change in interfacial electron transfer resistance (R-et) of the biosensor using a redox couple of [Fe(CN)(6)](3-/4-) as the probe was monitored. The change of the electron transfer resistance (Delta R-et) of the biosensor was linear with the concentration of adenosine in the range from 1.0 nM to 100 nM. Pie fabricated sensor was shown to exhibit high sensitivity, desirable selectivity and good stability.
引用
收藏
页码:1781 / 1785
页数:5
相关论文
共 50 条
  • [1] Reagentless aptamer based impedance biosensor for monitoring a neuro-inflammatory cytokine PDGF
    Liao, Wei
    Cui, Xinyan Tracy
    BIOSENSORS & BIOELECTRONICS, 2007, 23 (02): : 218 - 224
  • [2] Dehydrogenase based reagentless biosensor for monitoring phenylketonuria
    Weiss, David J.
    Dorris, Megan
    Loh, Amanda
    Peterson, Laura
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11): : 2436 - 2441
  • [3] Determination of endotoxin through an aptamer-based impedance biosensor
    Su, Wenqiong
    Lin, Meng
    Lee, Hyuck
    Cho, MiSuk
    Choe, Woo-Seok
    Lee, Youngkwan
    BIOSENSORS & BIOELECTRONICS, 2012, 32 (01): : 32 - 36
  • [4] Reagentless biosensor for monitoring PKU in human urine
    Dorris, Megan K.
    Loh, Amanda
    Peterson, Laura
    Weiss, David J.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [5] Rapid nanomolar detection of methamphetamine in biofluids via a reagentless electrochemical aptamer-based biosensor
    Xie, Yu
    Wu, Shenghong
    Chen, Zhimin
    Jiang, Jinzhi
    Sun, Jianjun
    ANALYTICA CHIMICA ACTA, 2022, 1207
  • [6] An aptamer-based biosensor for detection of doxorubicin by electrochemical impedance spectroscopy
    Bahner, Nicole
    Reich, Peggy
    Frense, Dieter
    Menger, Marcus
    Schieke, Katharina
    Beckmann, Dieter
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (05) : 1453 - 1462
  • [7] An aptamer-based protein biosensor by detecting the amplified impedance signal
    Xu, Ying
    Yang, Lin
    Ye, Xiaoyan
    He, Pingang
    Fang, Yuzhi
    ELECTROANALYSIS, 2006, 18 (15) : 1449 - 1456
  • [8] An aptamer-based biosensor for detection of doxorubicin by electrochemical impedance spectroscopy
    Nicole Bahner
    Peggy Reich
    Dieter Frense
    Marcus Menger
    Katharina Schieke
    Dieter Beckmann
    Analytical and Bioanalytical Chemistry, 2018, 410 : 1453 - 1462
  • [9] Ozone monitoring based on a biosensor concept utilizing a reagentless alcohol oxidase electrode
    Stergiou, Dimitrios V.
    Prodromidis, Mamas I.
    Veltsistas, Panayotis G.
    Evmiridis, Nicholaos P.
    ANALYTICAL CHEMISTRY, 2006, 78 (13) : 4676 - 4682
  • [10] Highly sensitive electrochemiluminescent biosensor for adenosine based on structure-switching of aptamer
    Zhu, Xi
    Zhang, Yashan
    Yang, Weiqiang
    Liu, Qida
    Lin, Zhenyu
    Qiu, Bin
    Chen, Guonan
    ANALYTICA CHIMICA ACTA, 2011, 684 (1-2) : 121 - 125