Harmonic analysis of doubly fed induction generators

被引:0
|
作者
Lindholm, M [1 ]
Rasmussen, TW [1 ]
机构
[1] NEG Micon Control Syst AS, DK-8450 Hammel, Denmark
关键词
doubly fed induction generator; wind turbines; harmonic elimination;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper gives an overview of the frequency spectrum of the stator and rotor currents in a doubly fed induction generator (DFIG) used in wind power applications. The paper also presents a method to eliminate higher harmonies and interharmonics in the DFIG stator current. The method is implemented on a 40 kW laboratory model connected to the utility-grid, where the DFIG is supplied by a back-to-back 3-level NPC-converter.
引用
收藏
页码:837 / 841
页数:5
相关论文
共 50 条
  • [31] Reactive Capability Limitations of Doubly-fed Induction Generators
    Singh, Bharat
    Singh, S. N.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2009, 37 (04) : 427 - 440
  • [32] Online Parameter Identification Methods for Doubly Fed Induction Generators
    Thomsen, Soenke
    Rothenhagen, Kai
    Fuchs, Friedrich W.
    [J]. 2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, : 2735 - 2741
  • [33] Dynamic Programming Power Control for Doubly Fed Induction Generators
    Santos-Martin, David
    Rodriguez-Amenedo, Jose Luis
    Arnalte, Santiago
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (05) : 2337 - 2345
  • [34] Advanced modeling and analysis of the loading capability limits of doubly-fed induction generators
    Ahmed, M.
    El-Shimy, M.
    Badr, M. A.
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2014, 7 : 79 - 90
  • [35] Analysis of Small Signal Stability of Grid-Connected Doubly Fed Induction Generators
    Li, Shan-Ying
    Sun, Yu
    Wu, Tao
    Li, Qun-Ju
    Liu, Hui
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [36] Two RX Models of Doubly-Fed Induction Generators for Load Flow Analysis
    Huang, Chengchen
    [J]. 2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [37] Modeling and Fault Analysis of Doubly Fed Induction Generators for Gansu Wind Farm Application
    Kheshti, Mostafa
    Kang, Xiaoning
    Song, Guobing
    Jiao, Zaibin
    [J]. CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2015, 38 (01): : 52 - 64
  • [38] Analysis of Doubly Fed Induction Wind-Power Generators in LVRT field testing
    Zeng, Hui
    Liu, Jinsong
    Wang, Gang
    Ge, Yangyang
    [J]. 2012 POWER ENGINEERING AND AUTOMATION CONFERENCE (PEAM), 2012, : 141 - 144
  • [39] Design and Analysis of a Three-Phase Rotary Transformer for Doubly Fed Induction Generators
    Zhong, Hui
    Zhao, Lin
    Li, Xiao
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (04) : 2791 - 2796
  • [40] Evaluating Harmonic Distortions in Brushless Doubly Fed Induction Machines
    Strous, Tim D.
    Wang, Xuezhou
    Polinder, Henk
    Ferreira, Jan A.
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2017, 53 (01)