Hemocompatibility of new magnetically-levitated centrifugal pump technology compared to the CentriMag adult pump

被引:5
|
作者
Schibilsky, David [1 ]
Takatani, Setsuo [2 ]
Schibilsky, Barbara [1 ]
Graf, Tobias [3 ]
da Silva, Diana Michels [3 ]
Wendel, Hans Peter [4 ]
Avci-Adali, Meltem [4 ]
Schlensak, Christian [4 ]
机构
[1] Univ Heart Ctr Freiburg Bad Krozingen, Dept Cardiovasc Surg, Freiburg, Germany
[2] Tokyo Med & Dent Univ, Tokyo, Japan
[3] Univ Med Ctr Schleswig Holstein, Dept Cardiol Angiol & Intens Care Med, Campus Luebeck, Lubeck, Germany
[4] Univ Med Ctr Tuebingen, Dept Thorac & Cardiovasc Surg, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
关键词
MEDTECH MAG-LEV; BLOOD PUMP; BIOCOMPATIBILITY ASSESSMENT; VENTRICULAR ASSIST; SINGLE-USE; SUPPORT; BRIDGE;
D O I
10.1038/s41598-020-78709-0
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The specific hemocompatibility properties of mechanical-circulatory-support (MCS)-pump technologies have not previously been described in a comparable manner. We thus investigated the hemocompatibility-indicating marker of a new magnetically-levitated (MagLev) centrifugal pump (MT-Mag) in a human, whole-blood mock-loop for 360 min using the MCS devices as a driving component. We compared those results with the CentriMag adult (C-Mag) device under the same conditions according to ISO10993-4. Blood samples were analyzed via enzyme-linked-immunosorbent-assay (ELISA) for markers of coagulation, complement system, and the inflammatory response. The time-dependent activation of the coagulation system was measured by detecting thrombin-anti-thrombin complexes (TAT). The activation of the complement system was determined by increased SC5b-9 levels in both groups. A significant activation of neutrophils (PMN-elastase) was detected within the C-Mag group, but not in the MT-Mag group. However, the amount of PMN-elastase at 360 min did not differ significantly between groups. The activation of the complement and coagulation system was found to be significantly time-dependent in both devices. However, coagulation activation as determined by the TAT level was lower in the MT-Mag group than in the C-Mag group. This slight disparity could have been achieved by the optimized secondary flow paths and surface coating, which reduces the interaction of the surface with blood.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Disposable magnetically levitated centrifugal blood pump: Design and in vitro performance
    Hoshi, H
    Asama, J
    Shinshi, T
    Ohuchi, K
    Nakamura, M
    Mizuno, T
    Arai, H
    Shimokohbe, A
    Takatani, S
    [J]. ARTIFICIAL ORGANS, 2005, 29 (07) : 520 - 526
  • [12] HeartQuest ventricular assist device magnetically levitated centrifugal blood pump
    Bearnson, GB
    Jacobs, GB
    Kirk, J
    Khanwilkar, PS
    Nelson, KE
    Long, JW
    [J]. ARTIFICIAL ORGANS, 2006, 30 (05) : 339 - 346
  • [13] Hydraulic Analysis and Optimization in impeller of Magnetically Levitated Centrifugal Blood Pump
    Zhang, Huimin
    Zhu, Qi
    [J]. FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE II, PTS 1-6, 2012, 121-126 : 1204 - 1208
  • [14] HeartMate III: Pump design for a centrifugal LVAD with a magnetically levitated rotor
    Bourque, K
    Gernes, DB
    Loree, HM
    Richardson, JS
    Poirier, VL
    Barletta, N
    Fleischli, A
    Foiera, G
    Gempp, TM
    Schoeb, R
    Litwak, KN
    Akimoto, T
    Watach, MJ
    Litwak, P
    [J]. ASAIO JOURNAL, 2001, 47 (04) : 401 - 405
  • [15] Levitronix CentriMag Third-Generation Magnetically Levitated Continuous Flow Pump as Bridge to Solution
    Loforte, Antonio
    Montalto, Andrea
    Ranocchi, Federico
    Della Monica, Paola Lilla
    Casali, Giovanni
    Lappa, Angela
    Contento, Carlo
    Musumeci, Francesco
    [J]. ASAIO JOURNAL, 2011, 57 (04) : 247 - 253
  • [16] The CentriMag: A new optimized centrifugal blood pump with levitating impeller
    Mueller, JP
    Kuenzli, A
    Reuthebuch, O
    Dasse, K
    Kent, S
    Zuend, G
    Turina, MI
    Lachat, ML
    [J]. HEART SURGERY FORUM, 2004, 7 (05): : E477 - E480
  • [17] Prevention of thrombus formation in blood pump by mechanical circular orbital excitation of impeller in magnetically levitated centrifugal pump
    Hatakenaka, Kohei
    Hijikata, Wataru
    Fujiwara, Tatsuki
    Ohuchi, Katsuhiro
    Inoue, Yusuke
    [J]. ARTIFICIAL ORGANS, 2023, 47 (02) : 425 - 431
  • [18] Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump
    Zhang, JT
    Gellman, B
    Koert, A
    Dasse, KA
    Gilbert, RJ
    Griffith, BP
    Wu, ZJJ
    [J]. ARTIFICIAL ORGANS, 2006, 30 (03) : 168 - 177
  • [19] Mechanical antithrombogenic properties by vibrational excitation of the impeller in a magnetically levitated centrifugal blood pump
    Murashige, Tomotaka
    Hijikata, Wataru
    [J]. ARTIFICIAL ORGANS, 2019, 43 (09) : 849 - 859
  • [20] A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller
    Asama, J
    Shinshi, T
    Hoshi, H
    Takatani, S
    Shimokohbe, A
    [J]. ARTIFICIAL ORGANS, 2006, 30 (03) : 160 - 167