SwarmPS:: Rapid, semi-automated single particle selection software

被引:28
|
作者
Woolford, David
Ericksson, Geoffery
Rothnagel, Rosalba
Muller, David
Landsberg, Michael J.
Pantelic, Radosav S.
McDowall, Alasdair
Pailthorpe, Bernard
Young, Paul R.
Hankamer, Ben [1 ]
Banks, Jasmine
机构
[1] Univ Queensland, Inst Mol Biosci, Brisbane, Qld 4072, Australia
[2] Univ Queensland, Inst Brain, Brisbane, Qld 4072, Australia
[3] Univ Queensland, Sch Mol & Microbial Sci, Brisbane, Qld 4072, Australia
[4] Univ Queensland, Ctr Microscopy & Microanalysis, Brisbane, Qld 4072, Australia
[5] Univ Queensland, Sch Phys Sci, Brisbane, Qld 4072, Australia
[6] Univ Queensland, Adv Computat Modelling Ctr, Brisbane, Qld 4072, Australia
基金
澳大利亚研究理事会;
关键词
electron microscopy; electron cryomicroscopy; cryoelectron microscopy; single particle analysis; automatic particle detection; particle selection; particle picking; software;
D O I
10.1016/j.jsb.2006.04.006
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Single particle analysis (SPA) Coupled with high-resolution electron cryo-microscopy is emerging as a powerful technique for the structure determination of membrane protein complexes and soluble macromolecular assemblies. Current estimates suggest that similar to 10(4)-10(5) particle projections are required to attain a 3 angstrom resolution 3D reconstruction (symmetry dependent). Selecting this number of molecular projections differing in size, shape and symmetry is a rate-limiting step for the automation of 3D image reconstruction. Here, we present Swarm(PS), a feature rich GUI based software package to manage large scale, semi-automated particle picking projects. The software provides cross-correlation and edge-detection algorithms. Algorithm-specific parameters are transparently and automatically determined through user interaction with the image, rather than by trial and error. Other features include multiple image handling (similar to 10(2)), local and global particle selection options, interactive image freezing, automatic particle centering, and full manual override to correct false positives and negatives. Swarm(PS) is user friendly, flexible, extensible, fast, and capable of exporting boxed out projection images, or particle coordinates, compatible with downstream image processing suites. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:174 / 188
页数:15
相关论文
共 50 条
  • [31] Rapid geometric modeling for visual simulation using semi-automated reconstruction from single image
    Feng, Chen
    Deng, Fei
    Kamat, Vineet R.
    [J]. ENGINEERING WITH COMPUTERS, 2014, 30 (01) : 31 - 39
  • [32] Rapid, semi-automated protein terminal characterization using ISDetect
    Corey E Bakalarski
    Yutian Gan
    Ingrid Wertz
    Jennie R Lill
    Wendy Sandoval
    [J]. Nature Biotechnology, 2016, 34 : 811 - 813
  • [33] RAPID, SEMI-AUTOMATED, MULTISAMPLE METHOD FOR QUANTITATION OF GLYCOSYLATED HEMOGLOBINS
    WISETH, R
    SHETELIG, AW
    FOLLING, I
    [J]. ACTA ENDOCRINOLOGICA, 1978, 88 : 78 - &
  • [35] Rapid, semi-automated protein terminal characterization using ISDetect
    Bakalarski, Corey E.
    Gan, Yutian
    Wertz, Ingrid
    Lill, Jennie R.
    Sandoval, Wendy
    [J]. NATURE BIOTECHNOLOGY, 2016, 34 (08) : 811 - +
  • [36] A Rapid Semi-automated Literature Review on Legal Precedents Retrieval
    Silva, Hugo
    Antonio, Nuno
    Bacao, Fernando
    [J]. PROGRESS IN ARTIFICIAL INTELLIGENCE, EPIA 2022, 2022, 13566 : 53 - 65
  • [37] Semi-Automated Emergency Landing Site Selection Approach for UAVs
    Ayhan, Bulent
    Kwan, Chiman
    Um, Yool-Bin
    Budavari, Bence
    larkin, Jude
    [J]. IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2019, 55 (04) : 1892 - 1906
  • [38] SEMI-AUTOMATED MATHEMATICS
    GUARD, JR
    OGLESBY, FC
    BENNETT, JH
    SETTLE, LG
    [J]. JOURNAL OF THE ACM, 1969, 16 (01) : 49 - &
  • [39] STRESS: A Semi-Automated, Fully Replicabile Approach for Project Selection
    Falessi, Davide
    Smith, Wyatt
    Serebrenik, Alexander
    [J]. 11TH ACM/IEEE INTERNATIONAL SYMPOSIUM ON EMPIRICAL SOFTWARE ENGINEERING AND MEASUREMENT (ESEM 2017), 2017, : 151 - 156
  • [40] Semi-Automated Region of Interest Selection Tool for Mammographic Image
    Nordin, Zailani Mohd
    Isa, Nor Ashidi Mat
    Zamli, Kamal Zuhairi
    Ngah, Umi Kalthum
    Aziz, Mohd Ezane
    [J]. INTERNATIONAL SYMPOSIUM OF INFORMATION TECHNOLOGY 2008, VOLS 1-4, PROCEEDINGS: COGNITIVE INFORMATICS: BRIDGING NATURAL AND ARTIFICIAL KNOWLEDGE, 2008, : 117 - +