Single-Shot Steady-State Free Precession Can Detect Myocardial Edema in Patients: A Feasibility Study

被引:10
|
作者
Green, Jordin D. [1 ,2 ,3 ]
Clarke, James R. [2 ,3 ]
Flewitt, Jacqueline A. [2 ,3 ]
Friedrich, Matthias G. [2 ,3 ]
机构
[1] Siemens Healthcare, Calgary, AB, Canada
[2] Univ Calgary, Dept Cardiac Sci, Calgary, AB, Canada
[3] Univ Calgary, Dept Radiol, Calgary, AB, Canada
基金
加拿大健康研究院;
关键词
magnetic resonance (MR); steady-state free precession (SSFP); cardiac; myocardium; edema; infarction; INVERSION-RECOVERY; DELAYED ENHANCEMENT; INFARCTION; HEMORRHAGE; HEART; AREA; RISK;
D O I
10.1002/jmri.21868
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate the ability of single-shot, T-2/T-1 weighted steady-state free precession (SSFP) to detect myocardial edema in patients with an acute myocardial infarction. Materials and Methods: This study was performed in a series of patients (n = 10) referred for the assessment of acute myocardial infarcts (AMI). Localizers were used to obtain true short axis views of the left ventricle (LV). These views were used to plan and obtain T-2-weighted STIR (short TI inversion recovery) images of the LV. These slices were then acquired using single-shot dark blood-prepared SSFP with a large (31) number of dummy pulses. Lastly, Contrast agent was injected, and late enhancement (LE) images were acquired. Images were analyzed using a multi-segment model of the heart. SSFP images were compared with STIR images, with STIR images used as the standard of truth for the presence of edema. LE images were used to identify segments which were positive for microvascular obstruction. Results: All techniques were successful in all patients. A total of 312 segments were analyzed. Excluding segments positive for microvascular obstruction, SSFP had a sensitivity/specificity of 80%/89%. Including segments positive for microvascular obstruction, sensitivity/specificity was 71.%/88%. On a patient-based analysis, no AMI was missed using SSFP (sensitivity = 100%). Conclusion: Using single-shot SSFP to detect myocardial edema in patients with AMI is feasible with a moderate sensitivity and high specificity.
引用
收藏
页码:690 / 695
页数:6
相关论文
共 50 条
  • [21] Fast bound pool fraction mapping via steady-state magnetization transfer saturation using single-shot EPI
    Battiston, Marco
    Schneider, Torben
    Grussu, Francesco
    Yiannakas, Marios C.
    Prados, Ferran
    De Angelis, Floriana
    Wheeler-Kingshott, Claudia A. M. Gandini
    Samson, Rebecca S.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (03) : 1025 - 1040
  • [22] Steady-state free precession MR imaging: Improved myocardial tag persistence and signal-to-noise ratio for analysis of myocardial motion
    Markl, M
    Reeder, SB
    Chan, FP
    Alley, MT
    Herfkens, RJ
    Pelc, NJ
    RADIOLOGY, 2004, 230 (03) : 852 - 861
  • [23] Fat/water separation in single acquisition steady-state free precession using multiple echo radial trajectories
    Lu, AM
    Grist, TM
    Block, WF
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) : 1051 - 1057
  • [24] Steady-state free precession sequences in myocardial first-pass perfusion MR imaging: comparison with TurboFLASH imaging
    Hunold, P
    Maderwald, S
    Eggebrecht, H
    Vogt, FM
    Barkhausen, J
    EUROPEAN RADIOLOGY, 2004, 14 (03) : 409 - 416
  • [25] Simultaneous multi-slice steady-state free precession myocardial perfusion with iterative reconstruction and integrated motion compensation
    McElroy, Sarah
    Kunze, Karl P.
    Nazir, Muhummad Sohaib
    Speier, Peter
    Stab, Daniel
    Villa, Adriana D. M.
    Yazdani, Momina
    Vergani, Vittoria
    Roujol, Sebastien
    Neji, Radhouene
    Chiribiri, Amedeo
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 151
  • [26] Assessment of Magnetization Transfer Effects in Myocardial Tissue Using Balanced Steady-State Free Precession (bSSFP) Cine MRI
    Weber, Oliver M.
    Speier, Peter
    Scheffler, Klaus
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) : 699 - 705
  • [27] Steady-state free precession sequences in myocardial first-pass perfusion MR imaging: comparison with TurboFLASH imaging
    Peter Hunold
    Stefan Maderwald
    Holger Eggebrecht
    Florian M. Vogt
    Jörg Barkhausen
    European Radiology, 2004, 14 : 409 - 416
  • [28] Cardiac balanced steady-state free precession MRI at 0.35 T: a comparison study with 1.5 T
    Rashid, Shams
    Han, Fei
    Gao, Yu
    Sung, Kyunghyun
    Cao, Minsong
    Yang, Yingli
    Hu, Peng
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2018, 8 (07) : 627 - 636
  • [29] Feasibility of balanced steady-state free precession sequence at 1.5T for the evaluation of hepatic steatosis in obese children and adolescents
    Zhang, Hong-xi
    Fu, Jun-fen
    Lai, Can
    Tian, Feng-yu
    Su, Xiao-li
    Huang, Ke
    EUROPEAN RADIOLOGY, 2018, 28 (11) : 4479 - 4487
  • [30] Feasibility of balanced steady-state free precession sequence at 1.5T for the evaluation of hepatic steatosis in obese children and adolescents
    Hong-xi Zhang
    Jun-fen Fu
    Can Lai
    Feng-yu Tian
    Xiao-li Su
    Ke Huang
    European Radiology, 2018, 28 : 4479 - 4487