Feedforward control application in aerobic and anoxic biotrickling filters for H2S removal from biogas

被引:23
|
作者
Lopez, Luis R. [1 ]
Brito, Javier [2 ]
Mora, Mabel [1 ]
Almenglo, Fernando [2 ]
Baeza, Juan A. [1 ]
Ramirez, Martin [2 ]
Lafuente, Javier [1 ]
Cantero, Domingo [2 ]
Gabriel, David [1 ]
机构
[1] Univ Autonoma Barcelona, Escola Engn, Dept Chem Biol & Environm Engn, GENOCOV Res Grp, Bellaterra 08193, Spain
[2] Univ Cadiz, Dept Chem Engn & Food Technol, Fac Sci, Inst Univ Invest Vitivinicola & Agroalimentario I, Puerto Real, Cadiz, Spain
关键词
biotrickling filter; aerobic; anoxic; biogas; hydrogen sulfide; feedforward control; HYDROGEN-SULFIDE REMOVAL; OXYGEN-TRANSFER; PILOT-SCALE; CONTROL-SYSTEM; FLOW PATTERN; DESULFURIZATION; OPTIMIZATION; PERFORMANCE; IMPROVEMENT; FILTRATION;
D O I
10.1002/jctb.5575
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
BACKGROUNDFeedforward control was implemented at laboratory scale in an aerobic and an anoxic biotrickling filter (BTF) operating under fluctuating H2S loading rate (LR) conditions in order to show the capabilities and added value of this control strategy. Dynamic, long-term tests with variable H2S LR were performed to simulate disturbances in the inlet gas concentration with and without the implementation of a feedforward control loop based on trickling liquid velocity (TLV) and nitrate feeding rate manipulation for the aerobic and anoxic BTFs, respectively. RESULTSAn average LR of 80 g S-H2S m(-3) h(-1) with peaks and valleys of 141 and 28 gS-H2S m(-3) h(-1) were tested. At the highest H2S LR, a 68.4% and 62.6% reduction of maximum outlet H2S concentration, and 50.0% and 26.6% reduction of H2S cumulative mass emitted were reached in the aerobic and anoxic BTFs, respectively, thanks to the application of feedforward control strategies. The sulfate selectivity in the aerobic BTF was enhanced up to 100.6 5.0% under controlled conditions. In the anoxic BTF the sulfate selectivity was kept constant at 32.8% +/- 0.8%. CONCLUSIONDespite demonstrating that the feedforward controller significantly reduced the impact of disturbances, the utilization of TLV as manipulated variable in the aerobic reactor showed performance problems. However, the feedforward control through nitrate addition was shown to be an adequate, robust strategy for reducing the impact of load perturbation in anoxic BTFs. (c) 2018 Society of Chemical Industry
引用
收藏
页码:2307 / 2315
页数:9
相关论文
共 50 条
  • [41] The use of a silicone-based biomembrane for microaerobic H2S removal from biogas
    Pokoma-Krayzelova, Lucie
    Bartacek, Jan
    Vejmelkova, Dana
    Alvarez, Ana A.
    Slukova, Petra
    Prochazka, Jindrich
    Volcke, Eveline I. P.
    Jenicek, Pavel
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2017, 189 : 145 - 152
  • [42] Design of a bioreactor for the recovery of ferric sulfate used in removal of H2S from biogas
    Mesa, Mariadelmar M.
    Andrades, J.A.
    Macias, M.
    Cantero, D.
    [J]. Informacion Tecnologica, 2002, 13 (03): : 13 - 16
  • [43] In-situ removal of H2S from chicken manure biogas by injecting air
    Song, Yun-Long
    Mahdy, Ahmed
    Qiao, Wei
    Dong, Ren-Jie
    [J]. Zhongguo Huanjing Kexue/China Environmental Science, 2020, 40 (02): : 688 - 694
  • [44] Removal of hydrogen sulfide (H2S) from biogas for the community in the province of Maha Sarakham
    Pinate, W.
    Dangphonthong, D.
    Sirirach, S.
    Sukkhon, S.
    [J]. SIAM PHYSICS CONGRESS 2017 (SPC2017), 2017, 901
  • [45] Preliminary study on microbial desulfurization: Targeting h2s removal from biogas with a bioscrubber
    Prasetyo, Joni
    Senda, Semuel Pati
    Prasetyo, Dwi Husodo
    Rahmawati, Nurdiah
    Setyowati, Agustina Dyah
    [J]. Industrial Biotechnology, 2020, 16 (03) : 182 - 186
  • [46] Conversion of full-scale wet scrubbers to biotrickling filters for H2S control at publicly owned treatment works
    Gabriel, D
    Cox, HHJ
    Deshusses, MA
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING, 2004, 130 (10) : 1110 - 1117
  • [47] Simulation study on the removal of high concentration H2S waste gas by biotrickling filter
    Xie, Le
    Jiang, Chongwen
    [J]. Huagong Xuebao/CIESC Journal, 2021, 72 (08): : 4346 - 4353
  • [48] On-site Removal of H2S from Biogas Produced by Food Waste using an Aerobic Sludge Biofilter for Steam Reforming Processing
    Kang, Jong Won
    Jeong, Chang Moon
    Kim, Nag Jong
    Kim, Moon Il
    Chang, Ho Nam
    [J]. BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2010, 15 (03) : 505 - 511
  • [49] On-site removal of H2S from biogas produced by food waste using an aerobic sludge biofilter for steam reforming processing
    Jong Won Kang
    Chang Moon Jeong
    Nag Jong Kim
    Moon Il Kim
    Ho Nam Chang
    [J]. Biotechnology and Bioprocess Engineering, 2010, 15 : 505 - 511
  • [50] Investigation on the mechanism of H2S removal by biological activated carbon in a horizontal biotrickling filter
    Huiqi Duan
    Rong Yan
    Lawrence Choon Chiaw Koe
    [J]. Applied Microbiology and Biotechnology, 2005, 69 : 350 - 357