Head and Neck Radiation Dose and Radiation Safety for Interventional Physicians

被引:44
|
作者
Fetterly, Kenneth [1 ]
Schueler, Beth [2 ]
Grams, Michael [3 ]
Sturchio, Glenn [4 ]
Bell, Malcolm [1 ]
Gulati, Rajiv [1 ]
机构
[1] Mayo Clin, Dept Cardiovasc Dis, Rochester, MN USA
[2] Mayo Clin, Dept Radiol, Rochester, MN USA
[3] Mayo Clin, Dept Radiat Oncol, Rochester, MN USA
[4] Mayo Clin, Dept Diagnost Radiol, Jacksonville, FL USA
关键词
head and neck; interventional fluoroscopy; occupational radiation dose; radiation protection; ROBOTIC CATHETER ABLATION; CARDIAC-CATHETERIZATION; PROTECTION; EXPOSURE; DEVICES; TUMORS; BRAIN;
D O I
10.1016/j.jcin.2016.11.026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The first aim of this study was to assess the magnitude of radiation dose to tissues of the head and neck of physicians performing x-ray-guided interventional procedures. The second aim was to assess protection of tissues of the head offered by select wearable radiation safety devices. BACKGROUND Radiation dose to tissues of the head and neck is of significant interest to practicing interventional physicians. However, methods to estimate radiation dose are not generally available, and furthermore, some of the available research relating to protection of these tissues is misleading. METHODS Using a single representative geometry, scatter radiation dose to a humanoid phantom was measured using radiochromic film and normalized by the radiation dose to the left collar of the radioprotective thorax apron. Radiation protection offered by leaded glasses and by a radioabsorbent surgical cap was measured. RESULTS In the test geometry, average radiation doses to the unprotected brain, carotid arteries, and ocular lenses were 8.4%, 17%, and 50% of the dose measured at the left collar, respectively. Two representative types of leaded glasses reduced dose to the ocular lens on the side of the physician from which the scatter originates by 27% to 62% but offered no protection to the contralateral eye. The radioabsorbent surgical cap reduced brain dose by only 3.3%. CONCLUSIONS A method by which interventional physicians can estimate dose to head and neck tissues on the basis of their personal dosimeter readings is described. Radiation protection of the ocular lenses by leaded glasses may be incomplete, and protection of the brain by a radioabsorbent surgical cap was minimal. (C) 2017 by the American College of Cardiology Foundation.
引用
下载
收藏
页码:520 / 528
页数:9
相关论文
共 50 条
  • [41] FLUORIDE FOR THE HEAD AND NECK RADIATION PATIENT
    MYERS, RE
    MITCHELL, DL
    MILITARY MEDICINE, 1988, 153 (08) : 411 - 413
  • [42] Radiation induced sarcomas of the head and neck
    Wong, Timothy
    Kalavrezos, Nicholas
    Liew, Colin
    Jay, Amrita
    Lalabekyan, Bagrat
    Morley, Simon
    Beale, Timothy
    ORAL ONCOLOGY, 2013, 49 : S85 - S85
  • [43] ENDOCRINOPATHY FOLLOWING RADIATION TO THE HEAD AND NECK
    FOGEL, TD
    WEISSBERG, JB
    FISCHER, JJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (01): : 167 - 168
  • [44] REPAIR OF RADIATION COMPLICATIONS IN THE HEAD AND NECK
    LARSON, DL
    WORLD JOURNAL OF SURGERY, 1986, 10 (02) : 195 - 205
  • [45] Radiation Treatment of Head and Neck Cancer
    Yom, Sue S.
    SURGICAL ONCOLOGY CLINICS OF NORTH AMERICA, 2015, 24 (03) : 423 - +
  • [46] IMAGING OF RADIATION CHANGES IN THE HEAD AND NECK
    TARTAGLINO, LM
    RAO, VM
    MARKIEWICZ, DA
    SEMINARS IN ROENTGENOLOGY, 1994, 29 (01) : 81 - 91
  • [47] Radiation oncology of head and neck tumors
    King, GK
    Bergman, PJ
    Harris, D
    VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 1997, 27 (01) : 101 - +
  • [48] Radiation therapy in head and neck cancer
    Tribius, S.
    Petersen, C.
    Knecht, R.
    Ihloff, A. S.
    HNO, 2010, 58 (12) : 1168 - 1173
  • [49] Radiation techniques for head and neck tumors
    Bratengeier, K
    Pfreundner, L
    Flentje, M
    RADIOTHERAPY AND ONCOLOGY, 2000, 56 (02) : 209 - 220
  • [50] The head and neck radiation oncology patient
    Huber, MA
    Terezhalmy, GT
    QUINTESSENCE INTERNATIONAL, 2003, 34 (09): : 693 - 709