Head and Neck Radiation Dose and Radiation Safety for Interventional Physicians

被引:44
|
作者
Fetterly, Kenneth [1 ]
Schueler, Beth [2 ]
Grams, Michael [3 ]
Sturchio, Glenn [4 ]
Bell, Malcolm [1 ]
Gulati, Rajiv [1 ]
机构
[1] Mayo Clin, Dept Cardiovasc Dis, Rochester, MN USA
[2] Mayo Clin, Dept Radiol, Rochester, MN USA
[3] Mayo Clin, Dept Radiat Oncol, Rochester, MN USA
[4] Mayo Clin, Dept Diagnost Radiol, Jacksonville, FL USA
关键词
head and neck; interventional fluoroscopy; occupational radiation dose; radiation protection; ROBOTIC CATHETER ABLATION; CARDIAC-CATHETERIZATION; PROTECTION; EXPOSURE; DEVICES; TUMORS; BRAIN;
D O I
10.1016/j.jcin.2016.11.026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The first aim of this study was to assess the magnitude of radiation dose to tissues of the head and neck of physicians performing x-ray-guided interventional procedures. The second aim was to assess protection of tissues of the head offered by select wearable radiation safety devices. BACKGROUND Radiation dose to tissues of the head and neck is of significant interest to practicing interventional physicians. However, methods to estimate radiation dose are not generally available, and furthermore, some of the available research relating to protection of these tissues is misleading. METHODS Using a single representative geometry, scatter radiation dose to a humanoid phantom was measured using radiochromic film and normalized by the radiation dose to the left collar of the radioprotective thorax apron. Radiation protection offered by leaded glasses and by a radioabsorbent surgical cap was measured. RESULTS In the test geometry, average radiation doses to the unprotected brain, carotid arteries, and ocular lenses were 8.4%, 17%, and 50% of the dose measured at the left collar, respectively. Two representative types of leaded glasses reduced dose to the ocular lens on the side of the physician from which the scatter originates by 27% to 62% but offered no protection to the contralateral eye. The radioabsorbent surgical cap reduced brain dose by only 3.3%. CONCLUSIONS A method by which interventional physicians can estimate dose to head and neck tissues on the basis of their personal dosimeter readings is described. Radiation protection of the ocular lenses by leaded glasses may be incomplete, and protection of the brain by a radioabsorbent surgical cap was minimal. (C) 2017 by the American College of Cardiology Foundation.
引用
收藏
页码:520 / 528
页数:9
相关论文
共 50 条
  • [1] Radiation dose and radiation protection for the head and neck of interventional physicians
    Fetterly, Kenneth
    Schueler, Beth
    Grams, Michael
    Sturchio, Glenn
    Bell, Malcolm
    Gulati, Rajiv
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B342 - B342
  • [2] Radiation Dose and Radiation Protection for Patients and Physicians During Interventional Procedure
    Chida, Koichi
    Kato, Mamoru
    Kagaya, Yutaka
    Zuguchi, Masayuki
    Saito, Haruo
    Ishibashi, Tadashi
    Takahashi, Shoki
    Yamada, Shogo
    Takai, Yoshihiro
    [J]. JOURNAL OF RADIATION RESEARCH, 2010, 51 (02) : 97 - 105
  • [3] Radiation dose to physicians' eye lens during interventional radiology
    Bahruddin, N. A.
    Hashim, S.
    Karim, M. K. A.
    Sabarudin, A.
    Ang, W. C.
    Salehhon, N.
    Bakar, K. A.
    [J]. 13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [4] Radiation dose to otologic structures during head and neck cancer radiation therapy
    Ondrey, FG
    Greig, JR
    Herscher, L
    [J]. LARYNGOSCOPE, 2000, 110 (02): : 217 - 221
  • [5] Radiation safety and knowledge: an international survey of 708 interventional pain physicians
    Provenzano, David Anthony
    Florentino, Samuel Ambrose
    Kilgore, Jason S.
    De Andres, Jose
    Sitzman, B. Todd
    Brancolini, Scott
    Lamer, Tim J.
    Buvanendran, Asokumar
    Carrino, John A.
    Deer, Timothy R.
    Narouze, Samer
    [J]. REGIONAL ANESTHESIA AND PAIN MEDICINE, 2021, 46 (06) : 469 - 476
  • [6] Radiation Dose Measurement with Newly Developed Head Phantom for Interventional Neuroradiology
    Abe, T.
    Uchiyama, Y.
    Tanaka, N.
    Hayabuchi, N.
    [J]. NEURORADIOLOGY JOURNAL, 2011, 24 (05): : 813 - 815
  • [7] Occupational radiation dose to the eye lens of physicians from departments of interventional radiology
    Lian, Meng-En
    Tsai, Yuan-Hsiung
    Li, I-Gung
    Hong, Yu-Han
    Chang, Szu-Li
    Tsai, Hui-Yu
    [J]. RADIATION MEASUREMENTS, 2020, 132 (132)
  • [8] Coaching Reduced the Radiation Dose of Pain Physicians by Half during Interventional Procedures
    Slegers, A. S.
    Gultuna, I.
    Aukes, J. A.
    van Gorp, E. J. J. A. A.
    Blommers, F. M. N.
    Niehof, S. P.
    Bosman, J.
    [J]. PAIN PRACTICE, 2015, 15 (05) : 400 - 406
  • [9] Interventional Equipment and Radiation Safety
    Cleroux, Andreanne
    Hersh-Boyle, Rebecca
    Clarke, Dana L.
    [J]. VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2018, 48 (05) : 751 - +
  • [10] Radiation Dose Uncertainty in a Mouse Head and Neck Irradiation Model
    Gan, G. N.
    Eagles-Soukup, J.
    Raben, D.
    Jimeno, A.
    Altunbus, C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S790 - S790