Reduction of femoral shaft fractures in vitro by a new developed reduction robot system 'RepoRobo'

被引:50
|
作者
Füchtmeier, B
Egersdoerfer, S
Mai, R
Hente, R
Dragoi, D
Monkman, G
Nerlich, M
机构
[1] Univ Clin Regensburg, Dept Trauma Surg, D-93042 Regensburg, Germany
[2] Univ Appl Sci, Mechantron Res Unit, D-93042 Regensburg, Germany
[3] Univ Appl Sci, Dept Mech Engn, D-93042 Regensburg, Germany
关键词
fracture reduction; reduction robot; RepoRobo;
D O I
10.1016/j.injury.2004.05.019
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Closed reduction of the tong bones is associated with the use of considerable force. This force must be maintained for the reduction maneuver and fixation process. At present, apart from the extension table or the large AO distractor, only rather inadequate reduction aids are available. A solution to this problem is being sought in the form of a robotic system with which precision can be improved and the holding effort reduced. In the research project presented here, a synthetic femur with integrated tensioned mainspring and a 32-A3 type fracture served as a bone reduction model. The fracture was stabilized with a standard AO fixator. A Staubli robot (model RX130) was converted by appropriate modification so that it could be used for the reduction of femoral shaft fractures in vitro. The robot was equipped with a pneumatic 2-fingered gripper, on which the fingers have been modified so that they can grip the AO fixator clamp. A Force-Feed back-Sensor was inserted between the gripper and the robot to obtain online recordings of the forces and moments in all three axes. With this setup it is possible to achieve precise reduction of the fracture in all planes under visual control.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 50 条
  • [1] Fractures of the femoral shaft - Mechanics of reduction and fixation
    Charnley, J
    LANCET, 1944, 1 : 235 - 239
  • [2] Percutaneous reduction for closed nailing of femoral shaft fractures
    Farrar, MJ
    Binns, MS
    JOURNAL OF THE ROYAL COLLEGE OF SURGEONS OF EDINBURGH, 1996, 41 (04): : 267 - 268
  • [3] Percutaneous reduction for closed nailing of femoral shaft fractures
    Parker, P
    JOURNAL OF THE ROYAL COLLEGE OF SURGEONS OF EDINBURGH, 1997, 42 (01): : 61 - 61
  • [4] Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: A biomechanical study
    Weber-Spickschen, T. S.
    Oszwald, M.
    Westphal, R.
    Krettek, C.
    Wahl, F.
    Gosling, T.
    TECHNOLOGY AND HEALTH CARE, 2010, 18 (03) : 207 - 216
  • [5] DELAYED OPEN REDUCTION OF ISOLATED FRACTURES OF FEMORAL-SHAFT
    RUTHERFORD, RE
    BELL, JP
    SOUTHERN MEDICAL JOURNAL, 1975, 68 (10) : 1243 - 1244
  • [6] COMMINUTED SEGMENTED FRACTURES OF THE FEMORAL SHAFT - TREATMENT BY OPEN REDUCTION
    CARR, CR
    HEINIG, CF
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1963, 45 (07): : 1543 - 1544
  • [7] A novel reduction device for the minimally invasive treatment of femoral shaft fractures
    Jiang, Wei
    Lin, Yan
    Kotian, Ronak Naveenchandra
    Xie, Wen-Qing
    Li, Yu-Sheng
    Li, Guang-Heng
    Hu, Xin-Jia
    Xie, Jin-Hu
    Liu, Wen-Tao
    Zhang, Xiao-Ming
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2020, 12 (07): : 3917 - 3925
  • [8] Robotic Assisted Reduction of Femoral Shaft Fractures using Stewart Platform
    Majidifakhr, Kamran
    Kazemirad, Siavash
    Farahmand, Farzam
    MEDICINE MEETS VIRTUAL REALITY 17 - NEXTMED: DESIGN FOR/THE WELL BEING, 2009, 142 : 177 - +
  • [9] The flipped third fragment in femoral shaft fractures: A reason for open reduction?
    Layon, Daniel
    Morrell, Aidan T.
    Lee, Christopher
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (03): : 589 - 593
  • [10] Preoperative virtual reduction reduces femoral malrotation in the treatment of bilateral femoral shaft fractures
    Mohamed Omar
    Eduardo M. Suero
    Nael Hawi
    Sebastian Decker
    Christian Krettek
    Musa Citak
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 1385 - 1389