CT angiography: Shaded surface versus maximum intensity projection

被引:0
|
作者
Alberico, RA
Ozsvath, R
Casey, S
Patel, M
机构
[1] LONG ISL JEWISH MED CTR,NEW HYDE PK,NY 10042
[2] UNIV COLORADO,MED CTR,DENVER,CO 80202
关键词
D O I
10.2214/ajr.166.5.8615277
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:1227 / 1228
页数:2
相关论文
共 50 条
  • [31] Maximum intensity projection or volume rendering for pulmonary embolism detection in MR pulmonary angiography?
    Van Ooijen, PM
    Wielopolski, PA
    Oudkerk, M
    RADIOLOGY, 1998, 209P : 450 - 450
  • [32] 3-D angiography: Effect of the maximum intensity projection on the measurement of artery diameters
    Hyde, D
    Habets, D
    Fox, A
    Gulka, I
    Kalapos, P
    Lee, D
    Pelz, D
    Holdsworth, D
    MEDICAL PHYSICS, 2005, 32 (07) : 2408 - 2408
  • [33] APPLICATION OF STEREOSCOPIC VIEWING TO MAXIMUM INTENSITY PROJECTION IMAGES OBTAINED IN MR-ANGIOGRAPHY
    HEALY, JF
    WONG, WHM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (10) : 1968 - 1969
  • [34] Pulmonary nodules: Sensitivity of maximum intensity projection versus that of volume rendering of 3D multidetector CT data
    Peloschek, Philipp
    Sailer, Johannes
    Weber, Michael
    Herold, Christian J.
    Prokop, Mathias
    Schaefer-Prokop, Cornelia
    RADIOLOGY, 2007, 243 (02) : 561 - 569
  • [35] Quick evaluation of lower leg ischemia in patients with peripheral arterial disease by time maximum intensity projection CT angiography: a pilot study
    Zhang, Daming
    Zhou, Xueyan
    Zhang, Haiping
    Fan, Xiaobing
    Lin, Zehong
    Xue, Huadan
    Wang, Yining
    Jin, Zhengyu
    Chen, Yuexin
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [36] Quick evaluation of lower leg ischemia in patients with peripheral arterial disease by time maximum intensity projection CT angiography: a pilot study
    Daming Zhang
    Xueyan Zhou
    Haiping Zhang
    Xiaobing Fan
    Zehong Lin
    Huadan Xue
    Yining Wang
    Zhengyu Jin
    Yuexin Chen
    BMC Medical Imaging, 21
  • [37] The Usefulness of OsiriX in PET/CT Image Fusion and Maximum Intensity Projection (MIP)
    Choi, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S488 - S488
  • [38] Maximum intensity projection images in the detection of simulated pulmonary nodules by spiral CT
    Coakley, FV
    Cohen, MD
    Johnson, MS
    Gonin, R
    Hanna, MP
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (842): : 135 - 140
  • [39] Carotid artery stenosis: Optimization of CT angiography with a combination of shaded surface display and source images
    Papp, Z
    Patel, M
    Ashtari, M
    Takahashi, M
    Goldstein, J
    Maguire, W
    Herman, PG
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (04) : 759 - 763
  • [40] Intracranial aneurysms: Diagnostic accuracy of MR angiography with evaluation of maximum intensity projection and source images
    Korogi, Y
    Takahashi, M
    Mabuchi, N
    Nakagawa, T
    Fujiwara, S
    Horikawa, Y
    Miki, H
    OUchi, T
    Shiga, H
    Shiokawa, Y
    Watabe, T
    Furuse, M
    RADIOLOGY, 1996, 199 (01) : 199 - 207