Direct Determination of Cd, Co, Cu, Fe, Mn, Na, Ni, Pb, and Zn in Ethanol Fuel by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry

被引:23
|
作者
Leite, Clarice C. [1 ]
de Jesus, Alexandre [1 ]
Potes, Mariana L. [1 ]
Vieira, Mariana A. [2 ]
Samios, Dimitrios [1 ]
Silva, Marcia M. [1 ,3 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, Ctr Combust Biocombust Lubrificantes & Oleos CECO, BR-91501970 Porto Alegre, RS, Brazil
[2] Univ Fed Pelotas, Programa Posgrad Quim, BR-96160000 Capao Do Leao, RS, Brazil
[3] Univ Fed Bahia, INCT Energia & Ambiente, Inst Nacl Ciencia & Tecnol CNPq, BR-40170115 Salvador, Bahia, Brazil
关键词
AUTOMOTIVE GASOLINE; TRACE-ELEMENTS; ALCOHOL; COPPER; IRON;
D O I
10.1021/acs.energyfuels.5b01796
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A method to determine nine elements (Cd, Co, Cu, Fe, Mn, Na, Ni, Pb, and Zn) in ethanol fuel using high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) was developed. The proposed method consists of the direct analysis of samples, making use of inorganic standards for calibration and multi-element sequential determination. To evaluate the accuracy of the proposed method, the obtained results were compared to the results obtained by the following methods: (i) the standard method NBR 11331 for the determination of Cu and Fe in ethanol fuel by line source flame atomic absorption spectrometry (LS-FAAS), (ii) the standard method NBR 10422 for the determination of Na in ethanol fuel by flame photometry, and (iii) recovery tests for the other elements. Good accuracy was attained because the results obtained for Cu, Fe, and Na by the proposed method and the standard methods were not significantly different within a 95% level of confidence (Students t test) and the recovery tests for the other analytes ranged from 97 to 105%. Limits of detection of 0.006, 0.02, 0.001, 0.02, 0.003, 0.1, 0.04, 0.06, and 0.024 mg kg(-1) were obtained for Cd, Co, Cu, Fe, Mn, Na, Ni, Pb, and Zn, respectively. The relative standard deviations were in general lower than 3.0% for all analytes. The proposed method was shown to be an excellent alternative for the determination of metals in ethanol fuel, emphasizing multi-element sequential analysis, reducing the costs and analysis time, and, thus, can be recommended for routine analysis.
引用
下载
收藏
页码:7358 / 7363
页数:6
相关论文
共 50 条
  • [41] Direct determination of lead in bones using slurry sampling and high-resolution continuum source electrothermal atomic absorption spectrometry
    Husakova, Lenka
    Sidova, Tereza
    Ibrahimova, Lucie
    Svizelova, Monika
    Mikysek, Tomas
    ANALYTICAL METHODS, 2019, 11 (09) : 1254 - 1263
  • [42] Determination of Gold by High-Resolution Continuum Source Atomic Absorption Spectrometry with Chemical Vapor Generation
    Krawczyk, Magdalena
    Matusiewicz, Henryk
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2013, 24 (05) : 749 - 757
  • [43] Fast sequential determination of antimony and lead in pewter alloys using high-resolution continuum source flame atomic absorption spectrometry
    Dessuy, Morgana B.
    de Jesus, Robson M.
    Brandao, Geovani C.
    Ferreira, Sergio L. C.
    Vale, Maria Goreti R.
    Welz, Bernhard
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2013, 30 (01): : 202 - 207
  • [44] Evaluation of solid sampling for determination of Mo, Ni, Co, and V in soil by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Babos, Diego Victor
    Barros, Ariane Isis
    Ferreira, Edilene Cristina
    Gomes Neto, Jose Anchieta
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 130 : 39 - 44
  • [45] Optimisation of microwave digestion for determination of Fe, Zn, Mn and Cu in various legumes by flame atomic absorption spectrometry
    Erdogan, S
    Erdemoglu, SB
    Kaya, S
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2006, 86 (02) : 226 - 232
  • [46] Determination of Cr, Cu and Pb in industrial waste of oil shale using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    dos Passos, Adenilde S.
    Tonon, Gabriele F.
    Nakadi, Flavio V.
    Mangrich, Antonio S.
    de Andrade, Jailson B.
    Welz, Bernhard
    Vale, Maria Goreti R.
    ANALYTICAL METHODS, 2018, 10 (29) : 3645 - 3653
  • [47] A new chelating resin for preconcentration and determination of Mn(II), Ni(II), Cu(II), Zn(II), Cd(II), and Pb(II) by flame atomic absorption spectrometry
    Maheswari, MA
    Subramanian, MS
    JOURNAL OF AOAC INTERNATIONAL, 2003, 86 (06) : 1218 - 1224
  • [48] Direct determination of Zn in individual Daphnia magna specimens by means of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry
    Briceno, J.
    Belarra, M. A.
    De Schamphelaere, K. A. C.
    Vanblaere, S.
    Janssen, C. R.
    Vanhaecke, F.
    Resano, M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (04) : 503 - 510
  • [49] Determination of Total Sulfur in Agricultural Samples by High-Resolution Continuum Source Flame Molecular Absorption Spectrometry
    Virgilio, Alex
    Raposo, Jorge L., Jr.
    Cardoso, Arnaldo A.
    Nobrega, Joaquim A.
    Gomes Neto, Jose A.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (06) : 2197 - 2201
  • [50] Application of cellulose modified with p-aminobenzoic groups in preconcentration system for determination of Cu, Fe, Ni, and Zn in fuel ethanol samples by flame atomic absorption spectrometry
    de Castro, G. R.
    de Oliveira, J. D.
    Alcantara, I. L.
    Roldan, P. S.
    Padilha, C. C. F.
    Prado, A. G. S.
    Padilha, P. M.
    SEPARATION SCIENCE AND TECHNOLOGY, 2007, 42 (06) : 1325 - 1340