Comparison of the BD Veritor System for Flu A plus B with the Alere BinaxNOW Influenza A&B Card for Detection of Influenza A and B Viruses in Respiratory Specimens from Pediatric Patients

被引:29
|
作者
Hassan, Ferdaus [1 ,2 ]
Ashley Nguyen [1 ]
Formanek, Ashley [1 ]
Bell, James J. [1 ,2 ]
Selvarangan, Rangaraj [1 ,2 ]
机构
[1] Childrens Mercy Hosp & Clin, Dept Pathol & Lab Med, Kansas City, MO 64108 USA
[2] Univ Missouri, Sch Med, Kansas City, MO 64108 USA
关键词
PERFORMANCE; TESTS; KITS; A/B;
D O I
10.1128/JCM.02484-13
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The performance characteristics of two commercially available rapid tests for influenza, the BD Veritor System for Flu A+B (BD) and the Alere BinaxNOW influenza A&B card (BN), were evaluated using 200 frozen clinical specimens collected from January 2011 to June 2012 from pediatric patients. Real-time reverse transcriptase PCR (RT-PCR) was used as the gold standard to evaluate the results obtained by the two different assays. Of the 200 specimens tested, real-time RT-PCR assay detected influenza A or B virus in 116 samples, while BD detected 104 samples and BN detected 84 samples as positive. The overall sensitivity and specificity for detection of both influenza A and B virus in comparison to those of real-time RT-PCR were 89.6% (95% confidence interval [CI], 82.2 to 94.3) and 98.8% (95% CI, 92.6 to 99.9) for BD Veritor and 72.4% (95% CI, 63.2 to 80.0) and 100% (95% CI, 94.5 to 100.0) for BinaxNOW. Workflow analysis indicated that overall processing times for a batch size of 10 specimens were virtually identical between both systems. Overall, these results indicate that the BD Veritor assay was more sensitive than the BinaxNOW assay in detection of influenza A and B viruses in respiratory specimens from pediatric patients.
引用
收藏
页码:906 / 910
页数:5
相关论文
共 50 条
  • [21] EVALUATION OF THE ESPLINETM INFLUENZA A & B-N FOR THE DETECTION OF INFLUENZA A AND B IN RESPIRATORY SPECIMENS
    De Witte, Evy
    Peeters, Charlotte
    Goossens, Herman
    Ieven, Margareta
    [J]. ACTA CLINICA BELGICA, 2012, 67 (01): : 68 - 68
  • [22] Prospective Comparison of ProFlu plus TM with Simplexa Flu A/B & RSV, Eragen ASR and LightCycler PCR for the Detection of Influenza A/B and RSV in Respiratory Specimens
    Espy, M.
    Sloan, L. M.
    Schneider, S. K.
    Pritt, B. S.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2012, 14 (06): : 672 - 673
  • [23] Comparison of the Accula Influenza A/B PCR Assay and Alere i Influenza A/B Isothermal Nucleic Amplification Assay for the Detection of Influenza in Adult and Pediatric Populations
    Young, S.
    Cai, H.
    Cary, R. B.
    Cai, G.
    Gastelum, S.
    Giles, J.
    Grkovich, A.
    Lindberg, C.
    Monroe, J.
    Thomas, D.
    Vo, L.
    Zeis, J.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2017, 19 (06): : 978 - 978
  • [24] Prospective evaluation of the Alere i Influenza A&B nucleic acid amplification versus Xpert Flu/RSV
    Van, J. C. Nguyen
    Camelena, F.
    Dahoun, M.
    Pilmis, B.
    Mizrahi, A.
    Lourtet, J.
    Behillil, S.
    Enouf, V.
    Le Monnier, A.
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2016, 85 (01) : 19 - 22
  • [25] The development of POCTEM Flu A/B - A point of care test for the detection of influenza A and influenza B viruses.
    Imoarai, T
    Saitoh, N
    Aki, M
    Amatsuji, Y
    Uemura, Y
    Yokoyama, K
    [J]. CLINICAL CHEMISTRY, 2001, 47 (06) : A184 - A184
  • [26] Analytical performance of the BD veritor™ system for rapid detection of influenza virus A and B in a primary healthcare setting
    Mese, Sevim
    Akan, Hulya
    Badur, Selim
    Uyanik, Aysun
    [J]. BMC INFECTIOUS DISEASES, 2016, 16
  • [27] Analytical performance of the BD veritor™ system for rapid detection of influenza virus A and B in a primary healthcare setting
    Sevim Mese
    Hulya Akan
    Selim Badur
    Aysun Uyanik
    [J]. BMC Infectious Diseases, 16
  • [28] Evaluation of the Alere i Influenza A&B Nucleic Acid Amplification Test by Use of Respiratory Specimens Collected in Viral Transport Medium
    Bell, J. Jeremiah
    Selvarangan, Rangaraj
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (11) : 3992 - 3995
  • [29] Comparison of the performance of the rapid antigen detection actim Influenza A&B test and RT-PCR in different respiratory specimens
    Ghebremedhin, B.
    Engelmann, I.
    Koenig, W.
    Koenig, B.
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2009, 58 (03) : 365 - 370
  • [30] Evaluation of the molecular Xpert Xpress Flu/RSV assay vs. Alere i Influenza A & B assay for rapid detection of influenza viruses
    Chen, J. H.
    Lam, H. Y.
    Yip, C. C.
    Cheng, V. C.
    Chan, J. F.
    Leung, T. H.
    Sridhar, S.
    Chan, K. H.
    Tang, B. S.
    Yuen, K. Y.
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2018, 90 (03) : 177 - 180