Comparison of the BD Veritor System for Flu A plus B with the Alere BinaxNOW Influenza A&B Card for Detection of Influenza A and B Viruses in Respiratory Specimens from Pediatric Patients

被引:29
|
作者
Hassan, Ferdaus [1 ,2 ]
Ashley Nguyen [1 ]
Formanek, Ashley [1 ]
Bell, James J. [1 ,2 ]
Selvarangan, Rangaraj [1 ,2 ]
机构
[1] Childrens Mercy Hosp & Clin, Dept Pathol & Lab Med, Kansas City, MO 64108 USA
[2] Univ Missouri, Sch Med, Kansas City, MO 64108 USA
关键词
PERFORMANCE; TESTS; KITS; A/B;
D O I
10.1128/JCM.02484-13
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The performance characteristics of two commercially available rapid tests for influenza, the BD Veritor System for Flu A+B (BD) and the Alere BinaxNOW influenza A&B card (BN), were evaluated using 200 frozen clinical specimens collected from January 2011 to June 2012 from pediatric patients. Real-time reverse transcriptase PCR (RT-PCR) was used as the gold standard to evaluate the results obtained by the two different assays. Of the 200 specimens tested, real-time RT-PCR assay detected influenza A or B virus in 116 samples, while BD detected 104 samples and BN detected 84 samples as positive. The overall sensitivity and specificity for detection of both influenza A and B virus in comparison to those of real-time RT-PCR were 89.6% (95% confidence interval [CI], 82.2 to 94.3) and 98.8% (95% CI, 92.6 to 99.9) for BD Veritor and 72.4% (95% CI, 63.2 to 80.0) and 100% (95% CI, 94.5 to 100.0) for BinaxNOW. Workflow analysis indicated that overall processing times for a batch size of 10 specimens were virtually identical between both systems. Overall, these results indicate that the BD Veritor assay was more sensitive than the BinaxNOW assay in detection of influenza A and B viruses in respiratory specimens from pediatric patients.
引用
收藏
页码:906 / 910
页数:5
相关论文
共 50 条
  • [1] Prompt detection of influenza A and B viruses using the BD Veritor™ System Flu A plus B, Quidele® Sofia® Influenza A plus B FIA, and Alere BinaxNOW® Influenza A&B compared to real-time reverse transcription-polymerase chain reaction (RT-PCR)
    Dunn, Jim
    Obuekwe, Joy
    Baun, Traci
    Rogers, Justin
    Patel, Twinkle
    Snow, Linda
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2014, 79 (01) : 10 - 13
  • [2] Evaluation of Alere i Influenza A&B for Rapid Detection of Influenza Viruses A and B
    Nie, Shuping
    Roth, Richard B.
    Stiles, Jeffrey
    Mikhlina, Albina
    Lu, Xuedong
    Tang, Yi-Wei
    Babady, N. Esther
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (09) : 3339 - 3344
  • [3] Performance Evaluation of Alere i Influenza A&B in Detecting Influenza Viruses A and B
    Kim, Ha Nui
    Jang, Woong Sik
    Nam, Jeonghun
    Mihn, Do-Cic
    Lim, Chae Seung
    [J]. ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2021, 51 (01): : 106 - 111
  • [4] Comparison of the Coris Influ A plus B K-SeT® and BD Veritor Flu A plus B® for rapid detection of influenza viruses in respiratory samples from 3 consecutive flu seasons in Belgium
    Vandamme, Sarah
    Van Cleempoel, Shauni
    Michiels, Mindy
    Goossens, Herman
    Jansens, Hilde
    Matheeussen, Veerle
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2019, 94 (03) : 227 - 230
  • [5] Evaluation of the Alere i Influenza A&B assay for rapid identification of influenza A and influenza B viruses
    Cecilia Chiarella, Flavia
    Culebras, Esther
    Enrique Fuentes-Ferrer, Manuel
    Jose Picazo, Juan
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2016, 65 : 456 - 461
  • [6] Analytical performance of the Alere™ i Influenza A&B assay for the rapid detection of influenza viruses
    Riazzo, Cristina
    Perez-Ruiz, Mercedes
    Sanbonmatsu-Gamez, Sara
    Pedrosa-Corral, Irene
    Gutierrez-Fernandez, Jose
    Navarro-Mari, Jose-Maria
    [J]. ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2017, 35 (07): : 438 - 440
  • [7] Performance of the Alere i influenza A&B assay and mariPOC test for the rapid detection of influenza A and B viruses
    Jokela, Pia
    Vuorinen, Tytti
    Waris, Matti
    Manninen, Raija
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2015, 70 : 72 - 76
  • [8] Evaluation of the limit of detection of the BD Veritor™ system flu A plus B test and two rapid influenza detection tests for influenza virus
    Peters, Timothy R.
    Blakeney, Elizabeth
    Vannoy, Lauren
    Poehling, Katherine A.
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2013, 75 (02) : 200 - 202
  • [9] Comparison of Alere i Influenza A & B, Xpert Flu plus RSV Xpress, and Sofia Influenza A plus B FIA for Influenza A & B Detection in Point of Care (POC) Setting
    vonRentzell, J. E.
    Mc Nally, M. C.
    Slesar, A. J.
    Wojcicki, W.
    Schreckenberger, P. C.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2016, 18 (06): : 974 - 974
  • [10] Evaluation of Alere i Influenza System for Rapid Detection of Influenza Viruses A and B
    Nie, S.
    Stiles, J.
    Mikhlina, A.
    Lu, X.
    Babady, E.
    Tang, Y. W.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (06): : 887 - 887