Body composition measurements using bioimpedance analysis in peritoneal dialysis patients are affected by the presence of dialysate

被引:13
|
作者
Kang, Seok Hui [1 ]
Cho, Kyu Hyang [1 ]
Park, Jong Won [1 ]
Yoon, Kyung Woo [1 ]
Do, Jun Young [1 ]
机构
[1] Yeungnam Univ Hosp, Dept Internal Med, Div Nephrol, Taegu 705717, South Korea
关键词
bioimpedance analysis; body composition; dialysate; peritoneal dialysis; BIOELECTRICAL-IMPEDANCE ANALYSIS; MULTIFREQUENCY BIOIMPEDANCE; CARDIOVASCULAR RISK; KIDNEY-DISEASE; VOLUME; ASSESSMENTS; MORTALITY;
D O I
10.1111/nep.12322
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The presence of peritoneal dialysate when performing bioimpedance analysis may affect body composition measurements. The aim of this study was to evaluate the impact of dialysate on body composition measurements in Asians. Forty-one patients undergoing maintenance peritoneal dialysis in our hospital peritoneal dialysis unit were included in this study. Dialysate was drained from the abdomen prior to measurement, and bioimpedance analysis was performed using multi-frequency bioimpedance analysis, with each subject in a standing position (D-). Dialysate was then administered and the measurement was repeated (D+). The presence of peritoneal dialysate led to an increase in intracellular water (ICW), extracellular water (ECW), and total body water (D-: 20.33 +/- 3.72L for ICW and 13.53 +/- 2.54L for ECW; D+: 20.96 +/- 3.78L for ICW and 14.10 +/- 2.59L for ECW; P<0.001 for both variables). Total and trunk oedema indices were higher in the presence of peritoneal dialysate. In addition, the presence of peritoneal dialysate led to an overestimation of mineral content and free fat mass (FFM) for the total body; but led to an underestimation of body fat (D-: 45.80 +/- 8.26kg for FFM and 19.30 +/- 6.27kg for body fat; D+: 47.51 +/- 8.38kg for FFM and 17.59 +/- 6.47kg for body fat; P<0.001 for both variables). Our results demonstrate that the presence of peritoneal dialysate leads to an overestimation of FFM and an underestimation of fat mass. An empty abdomen is recommended when evaluating body composition using bioimpedance analysis.
引用
收藏
页码:727 / 731
页数:5
相关论文
共 50 条
  • [1] Does peritoneal dialysate affect body composition assessments using multi-frequency bioimpedance in peritoneal dialysis patients?
    Davenport, A.
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 (02) : 223 - 225
  • [2] Does peritoneal dialysate affect body composition assessments using multi-frequency bioimpedance in peritoneal dialysis patients?
    A Davenport
    [J]. European Journal of Clinical Nutrition, 2013, 67 : 223 - 225
  • [3] Effect of Intra-abdominal Dialysate on Bioimpedance-Derived Fluid Volume Status and Body Composition Measurements in Peritoneal Dialysis Patients
    Davenport, Andrew
    [J]. PERITONEAL DIALYSIS INTERNATIONAL, 2013, 33 (05): : 578 - 579
  • [4] Correlation of Body Composition Analysis with Anthropometric Measurements in Peritoneal Dialysis Patients
    Artan, Ayse Serra
    Gursu, Meltem
    Elcioglu, Omer Celal
    Yabaci, Aysegul
    Kazancioglu, Rumeyza
    [J]. BEZMIALEM SCIENCE, 2022, 10 (01): : 3 - 9
  • [5] Estimation of Body Composition in Dialysis Patients using Segmental Bioimpedance
    Zhu, Fansan
    Carter, Mary
    Thijssen, Stephan
    Kotanko, Peter
    Levin, Nathan W.
    [J]. 2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1361 - 1364
  • [6] ASSESSMENT OF BODY FLUID VOLUME USING THE BIOIMPEDANCE METHOD IN PERITONEAL DIALYSIS PATIENTS
    Moriishi, Misaki
    Kawanishi, Hideki
    Shintaku, Sadanori
    Tsuchiya, Shinichiro
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2020, 35 : 1520 - 1520
  • [7] Comparison of equations of resting and total energy expenditure in peritoneal dialysis patients using body composition measurements determined by multi-frequency bioimpedance
    El-Kateb, Sally
    Sridharan, Sivakumar
    Farrington, Ken
    Fan, Stanley
    Davenport, Andrew
    [J]. CLINICAL NUTRITION, 2018, 37 (02) : 646 - 650
  • [8] Comparison of bioimpedance analysis and dual-energy X-ray absorptiometry body composition measurements in peritoneal dialysis patients according to edema
    Kang, Seok Hui
    Cho, Kyu Hyang
    Park, Jong Won
    Yoon, Kyung Woo
    Do, Jun Young
    [J]. CLINICAL NEPHROLOGY, 2013, 79 (04) : 261 - 268
  • [9] Relationship between bioimpedance-determined body composition and peritoneal transport in peritoneal dialysis
    da Costa, Bernardo M.
    Del Peso, Gloria
    Bajo, Maria Auxiliadora
    Carreno, Gilda
    Ferreira, Marta
    Ferreira, Carina
    Selgas, Rafael
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2017, 40 (05): : 212 - 218
  • [10] Repeated Bioimpedance Measurements Predict Prognosis of Peritoneal Dialysis Patients
    Kim, Jwa-Kyung
    Song, Young Rim
    Lee, Hyung Seok
    Kim, Hyung Jik
    Kim, Sung Gyun
    [J]. AMERICAN JOURNAL OF NEPHROLOGY, 2018, 47 (02) : 120 - 129