Small-Animal PET Imaging of Isolated Perfused Rat Heart

被引:4
|
作者
Yamane, Tomohiko [1 ]
Park, Min-Jae [2 ]
Richter, Dominik [1 ]
Nekolla, Stephan G. [3 ]
Javadi, Mehrbod S. [4 ]
Lapa, Constantin [1 ]
Samnick, Samuel [1 ]
Buck, Andreas K. [1 ]
Herrmann, Ken [1 ]
Higuchi, Takahiro [1 ,2 ]
机构
[1] Univ Wurzburg, Dept Nucl Med, D-97080 Wurzburg, Germany
[2] Univ Wurzburg, Comprehens Heart Failure Ctr, D-97080 Wurzburg, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Nukl Med Klin & Poliklin, D-80290 Munich, Germany
[4] Johns Hopkins Univ, Russell H Morgan Dept Radiol, Div Nucl Med, Baltimore, MD USA
关键词
isolated perfused heart; PET; rat heart; myocardial infarction; MYOCARDIAL KINETICS; TC-99M-SESTAMIBI; REPERFUSION; SCANNER; TRACER; PROBE; MODEL;
D O I
10.2967/jnumed.113.129429
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The assessment of myocardial radiotracer kinetics, including cardiac extraction fraction and washout, requires the study of isolated perfused hearts to avoid analytic error due to tracer recirculation and systemic metabolites. Analysis of the isolated perfused rat heart by a high-resolution small-animal PET system may offer both reliable evaluation of cardiac tracer kinetics and tomographic images. Methods: An isolated perfused heart system was modified to accommodate the small PET gantry bore size. Isolated rat hearts were perfused via the Langendorff method under a constant flow of Krebs-Henseleit buffer containing F-18-FDG with a rate of 5 mL/min and placed in the field of view of the commercially available small-animal PET system. Dynamic PET imaging was then performed, with F-18-FDG uptake in the isolated perfused heart verified by gamma counter measurements. Additionally, a rat heart of myocardial infarction was also studied in this system with static PET imaging. Results: Dynamic PET acquisition of the isolated heart under constant F-18-FDG infusion demonstrated continuous increase of activity in the heart. Correlation between cardiac activity (MBq) measured with the PET system and measurements made with the gamma counter were excellent (R-2 = 0.98, P < 0.001, n = 10). Tracer input rate (MBq/min) was also well correlated with cardiac tracer uptake rate (MBq/min) (R-2 = 0.87, P < 0.001, n = 12). PET imaging of the heart with myocardial infarction showed a clear tracer uptake defect corresponding to the location of scar tissue identified by autoradiography and histology. Conclusion: Combining the Langendorff method of isolated rat heart perfusion with high-resolution small-animal PET allows for the reliable quantification of myocardial tracer kinetics. This novel assay is readily adapted to available small-animal PET systems and may be useful for understanding myocardial PET tracer kinetics.
引用
收藏
页码:495 / 499
页数:5
相关论文
共 50 条
  • [1] A new PET system for small-animal imaging
    Wilson, DW
    Furenlid, LR
    Barrett, HH
    Chen, YC
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3389 - 3392
  • [2] Innovations in Small-Animal PET/MR Imaging Instrumentation
    Tsoumpas, Charalampos
    Visvikis, Dimitris
    Loudos, George
    [J]. PET CLINICS, 2016, 11 (02) : 105 - +
  • [3] Multimodality imaging of tumor xenografts and metastases in mice with combined small-animal PET, small-animal CT, and bioluminescence imaging
    Deroose, Christophe M.
    De, Abhijit
    Loening, Andreas M.
    Chow, Patrick L.
    Ray, Pritha
    Chatziioannou, Arion F.
    Gambhir, Sanjiv S.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (02) : 295 - 303
  • [4] Quantitative imaging with the micro-pet small-animal pet tomograph
    Vaska, Paul
    Rubins, Daniel J.
    Alexoff, David L.
    Schiffert, Wynne K.
    [J]. INTERNATIONAL REVIEW OF NEUROBIOLOGY, VOL 73, 2006, 73 : 191 - +
  • [5] Small-animal PET cameras
    Jeavons, AP
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (08) : 1442 - 1443
  • [6] Advances in research - Small-animal imaging of tumour proliferation with PET
    Barthel, H
    Price, P
    Aboagye, EO
    [J]. LANCET ONCOLOGY, 2004, 5 (02): : 100 - 100
  • [7] Molecular imaging for transgenic mice using small-animal PET
    Maeda, Jun
    Ji, Bin
    Higuchi, Makoto
    Suhara, Tetsuya
    [J]. NEUROSCIENCE RESEARCH, 2008, 61 : S18 - S18
  • [8] Molecular imaging in neuroscience research with small-animal PET in rodents
    Xi, Wang
    Tian, Mei
    Zhang, Hong
    [J]. NEUROSCIENCE RESEARCH, 2011, 70 (02) : 133 - 143
  • [9] Small-animal optical imaging
    Ntziachristos, Vasilis
    Culver, Joseph P.
    Rice, Bradley W.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (01)
  • [10] Absolute Quantification for Small-Animal PET
    Keereman, Vincent
    Van Holen, Roel
    Vanhove, Christian
    Mollet, Pieter
    Vandenberghe, Stefaan
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3715 - 3719