A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse

被引:31
|
作者
Peters, Samuel [1 ]
Schiefer, Hans [1 ]
Plasswilm, Ludwig [1 ]
机构
[1] Kantonsspital St Gallen, Dept Radiat Oncol, CH-9007 St Gallen, Switzerland
来源
RADIATION ONCOLOGY | 2014年 / 9卷
关键词
IMRT; VMAT; Single arc; Double arc; Dose volume histogram; Plan comparison; MODULATED ARC THERAPY; CLINICAL IMPLEMENTATION; LEAF WIDTH; RADIOTHERAPY; ALGORITHM; DELIVERY; RAPIDARC; IMPACT; TOMOTHERAPY; SMARTARC;
D O I
10.1186/1748-717X-9-153
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The newest release of the Eclipse (Varian) treatment planning system (TPS) includes an optimizing engine for Elekta volumetric-modulated arc therapy (VMAT) planning. The purpose of this study was to evaluate this new algorithm and to compare it to intensity-modulated radiation therapy (IMRT) for various disease sites by creating single- and double-arc VMAT plans. Methods: A total of 162 plans were evaluated in this study, including 38 endometrial, 57 head and neck, 12 brain, 10 breast and 45 prostate cancer cases. The real-life IMRT plans were developed during routine clinical cases using the TPS Eclipse. VMAT plans were generated using a preclinical version of Eclipse with tumor-region-specific optimizing templates without interference of the operator: with one full arc (1A) and with two full arcs (2A), and with partial arcs for breast and prostate with hip implant cases. All plans were evaluated based on target coverage, homogeneity and conformity. The organs at risk (OARs) were analyzed according to plan objectives, such as the mean and maximum doses. If one or more objectives were exceeded, the plan was considered clinically unacceptable, and a second VMAT plan was created by adapting the optimization penalties once. Results: Compared to IMRT, single- and double-arc VMAT plans showed comparable or better results concerning the target coverage: the maximum dose in the target for 1A is the same as that for IMRT; for 2A, an average reduction of 1.3% over all plans was observed. The conformity showed a statistically significant improvement for both 1A (+3%) and 2A (+6%). The mean total body dose was statistically significant lower for the considered arc techniques (IMRT: 16.0 Gy, VMAT: 15.3 Gy, p < 0.001). However, the sparing of OARs shows individual behavior that depends strongly on the different tumor regions. A clear difference is found in the number of monitor units (MUs) per plan: VMAT shows a reduction of 31%. Conclusion: These findings demonstrate that based on optimizing templates with minimal interaction of the operator, the Eclipse TPS is able to achieve a plan quality for the Elekta VMAT delivery technique that is comparable to that of fixed-field IMRT. Plans with two arcs show better dose distributions than plans with one arc.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse
    Samuel Peters
    Hans Schiefer
    Ludwig Plasswilm
    [J]. Radiation Oncology, 9
  • [2] VMAT planning for Elekta linacs in the Varian planning system eclipse: a comparison study of VMAT plans with fixed field IMRT plans
    Peters, S.
    Schiefer, H.
    Socoliuc, A.
    Plasswilm, L.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (12) : 1077 - 1077
  • [3] Dosimetric evaluation of VMAT planning for Elekta Agility using Eclipse planning system
    Prokic, V.
    Roehner, F.
    Spiessens, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S717 - S718
  • [4] Modeling Elekta VersaHD using the Varian Eclipse treatment planning system for photon beams: A single-institution experience
    Zhang, You
    Le, Anh H.
    Igbal, Zohaib
    Chiu, Tsuicheng
    Gu, Xuejun
    Pugachev, Andrei
    Reynolds, Robert
    Park, Yang K.
    Lin, Mu-Han
    Stojadinovic, Strahinja
    Tian, Zhen
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (10): : 33 - 42
  • [5] Implementation of the Varian eclipse system for proton therapy treatment planning
    Newhauser, W.
    Zheng, Y.
    Fontenot, J.
    Koch, N.
    Polf, J.
    Schaffner, B.
    Titt, U.
    Zhang, X.
    Zhu, X.
    Mohan, R.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2284 - 2284
  • [6] A Treatment Planning Study Comparing Varian Volumetric Modulated Arc Therapy with IMRT using Oncentra Masterplan
    Chu, M.
    Millin, T.
    [J]. CLINICAL ONCOLOGY, 2011, 23 (03) : S20 - S21
  • [7] VMAT with a Synergy linear accelerator and the Eclipse treatment planning system
    Glessmer, S.
    Maass, T.
    Paque, R.
    Fehlauer, F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 106 - 106
  • [8] Commissioning of a commercial IMRT treatment planning system for standard elekta MLC
    Kim, H
    Chen, Y
    Xiao, Y
    Anne, P
    Galvin, J
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1348 - 1348
  • [9] Automatic Treatment Planning for IMRT, VMAT and IMPT
    Zhang, X.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 4008 - 4008
  • [10] 3D treatment planning system-Varian Eclipse for proton therapy planning
    Sahoo, Narayan
    Poenisch, Falk
    Zhang, Xiaodong
    Li, Yupeng
    Lii, MingFu
    Li, Heng
    Gautam, Archana S.
    Wu, Richard
    Gillin, Michael
    Zhu, Xiaorong R.
    [J]. MEDICAL DOSIMETRY, 2018, 43 (02) : 184 - 194