3D treatment planning system-Varian Eclipse for proton therapy planning

被引:7
|
作者
Sahoo, Narayan [1 ]
Poenisch, Falk [1 ]
Zhang, Xiaodong [1 ]
Li, Yupeng [1 ]
Lii, MingFu [1 ]
Li, Heng [1 ]
Gautam, Archana S. [1 ]
Wu, Richard [1 ]
Gillin, Michael [1 ]
Zhu, Xiaorong R. [1 ]
机构
[1] UT MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
关键词
Proton therapy planning; Intensity-modulated proton therapy; Robust optimization;
D O I
10.1016/j.meddos.2018.03.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The capabilities of the Eclipse treatment planning system (TPS) (Varian Medical Systems, Palo Alto, CA) for proton therapy treatment planning are described. Various steps involved in the planning process to produce a 3-dimensional (3D) dose distribution both for the passive scattering and pencil beam scanning proton beam therapy are outlined. Mitigation of range and setup uncertainties through robust optimization is discussed. Use of verification plans for patient treatment field dosimetry quality assurance (QA) is presented. Limitations of the Eclipse TPS and future developments are discussed. (C) 2018 American Association of Medical Dosimetrists.
引用
收藏
页码:184 / 194
页数:11
相关论文
共 50 条
  • [1] Implementation of the Varian eclipse system for proton therapy treatment planning
    Newhauser, W.
    Zheng, Y.
    Fontenot, J.
    Koch, N.
    Polf, J.
    Schaffner, B.
    Titt, U.
    Zhang, X.
    Zhu, X.
    Mohan, R.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2284 - 2284
  • [2] 3D Collision Viewer for Proton Therapy Treatment Planning
    Hojo, Y.
    Gillin, M.
    Suzuki, K.
    Wu, R.
    Zhu, X.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [3] Proton Treatment Planning On a Moby Mouse Phantom Using Varian Eclipse and TOPAS
    Abel, E.
    Katsis, A.
    Perl, J.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [4] 3D treatment planning for conformal proton therapy by spot scanning
    Lomax, A
    Pedroni, E
    Schaffner, B
    Scheib, S
    Schneider, U
    Tourovsky, A
    [J]. QUANTITATIVE IMAGING IN ONCOLOGY: 19TH L H GRAY CONFERENCE, 1996, : 67 - 71
  • [5] A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse
    Samuel Peters
    Hans Schiefer
    Ludwig Plasswilm
    [J]. Radiation Oncology, 9
  • [6] Monitor unit calculation in eclipse proton therapy treatment planning
    Slopsema, R.
    Yeung, D.
    Flampouri, S.
    Lin, L.
    Zhao, Z.
    Li, Z.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2470 - 2470
  • [7] A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse
    Peters, Samuel
    Schiefer, Hans
    Plasswilm, Ludwig
    [J]. RADIATION ONCOLOGY, 2014, 9
  • [8] An analysis of the clinical performance of Eclipse for PBS proton therapy treatment planning
    Rosas, S.
    Belosi, M.
    Bizzocchi, N.
    Morach, P.
    Zepter, S.
    Weber, D.
    Lomax, A.
    Hrbacek, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1207 - S1208
  • [9] 3D treatment planning for conformal radiation therapy
    Bruinvis, IAD
    [J]. RADIATION RESEARCH, VOL 2, CONGRESS PROCEEDINGS, 2000, : 644 - 647
  • [10] Commissioning of the Varian ECLIPSE eMC algorithm for clinical electron treatment planning
    Serban, M.
    Ruo, R.
    Sarfehnia, A.
    Parker, W.
    Evans, M.
    [J]. MEDICAL PHYSICS, 2012, 39 (07) : 4633 - 4633