Determining charge collection efficiency in parallel-plate liquid ionization chambers

被引:32
|
作者
Pardo-Montero, J. [1 ,2 ]
Gomez, F. [3 ]
机构
[1] Univ Liverpool, Sch Canc Studies, Liverpool L69 3BX, Merseyside, England
[2] Clatterbridge Ctr Oncol, Dept Phys, Wirral CH63 4YJ, Merseyside, England
[3] Univ Santiago de Compostela, Dept Fis Particulas, Santiago De Compostela, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 12期
关键词
INITIAL RECOMBINATION; ONSAGER THEORY; ISOOCTANE; IONS; TETRAMETHYLSILANE; RADIATION; DOSIMETRY; YIELD; BEAMS;
D O I
10.1088/0031-9155/54/12/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An accurate computation of the collection efficiency due to recombination has a capital importance in order to perform high-precision dose measurements with ionization chambers. The two-voltage method, developed to compute charge collection efficiency in gas chambers, cannot be directly applied to liquid-filled ionization chambers (LICs) due to the ionized charge strong dependence on the collection electric field, which is caused by initial recombination. It is shown that in order to apply the two-voltage method to parallel-plate LICs it is necessary to introduce explicitly the slope of the ionization charge yield with respect to the polarization voltage applied in the chamber. A three-voltage method is also proposed to avoid the introduction of the slope parameter. That method allows decoupling initial and general recombination. It leads to a nonlinear system of equations which can be solved using numerical methods.
引用
收藏
页码:3677 / 3689
页数:13
相关论文
共 50 条
  • [41] NOISE FACTORS FOR PARALLEL PLATE IONIZATION CHAMBERS
    PAGE, SA
    [J]. CANADIAN JOURNAL OF PHYSICS, 1988, 66 (06) : 527 - 529
  • [43] A STUDY OF PULSE SHAPES IN A PARALLEL-PLATE IONIZATION CHAMBER
    SHERR, R
    PETERSON, R
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1947, 18 (08): : 567 - 575
  • [44] SOME CHARACTERISTICS OF A GRIDDED PARALLEL-PLATE IONIZATION CHAMBER
    HERWIG, LO
    MILLER, GH
    UTTERBACK, NG
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1955, 26 (10): : 929 - 936
  • [45] Radiation efficiency of apertures in parallel-plate waveguides
    Marg, R
    Mallwitz, A
    Jacob, AF
    [J]. MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1999, 21 (03) : 159 - 162
  • [46] Monte Carlo study of the depth-dependent fluence perturbation in parallel-plate ionization chambers in electron beams
    Zink, K.
    Czarnecki, D.
    Looe, H. K.
    von Voigts-Rhetz, P.
    Harder, D.
    [J]. MEDICAL PHYSICS, 2014, 41 (11)
  • [47] The calibration of parallel-plate electron ionization chambers at NPL for use with the IPEM 2003 code of practice: summary data
    Bass, Graham
    Thomas, Russell
    Pearce, Julia
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08): : N115 - N124
  • [48] A LINEAR-QUADRATIC FIT FOR SATURATION CURVES OBTAINED UNDER CONTINUOUS IRRADIATION OF PARALLEL-PLATE IONIZATION CHAMBERS
    FALLONE, BG
    BENCOMO, JA
    [J]. MEDICAL PHYSICS, 1987, 14 (03) : 491 - 491
  • [49] ELECTRON BACKSCATTER CORRECTIONS FOR PARALLEL PLATE IONIZATION CHAMBERS
    HUNT, M
    KUTCHER, G
    BUFFA, A
    [J]. MEDICAL PHYSICS, 1985, 12 (04) : 525 - 525
  • [50] Measurements of Ballistic Deficits for Parallel Plate Ionization Chambers
    Sharma, S. L.
    Kumar, G. Anil
    Biswas, D. C.
    Choudhury, R. K.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1032 - 1034