An MR-compatible gyroscope-based arm movement tracking system

被引:5
|
作者
Shirinbayan, S. Iman [1 ]
Rieger, Jochem W. [1 ]
机构
[1] Carl Von Ossietzky Univ Oldenburg, Dept Psychol, Oldenburg, Germany
关键词
fMRI; Arm movement tracking system; MR-compatibility; analogue gyroscopes; OpenSim platform; FUNCTIONAL-ORGANIZATION; CORTICAL CONTROL; MOTOR CORTEX; DIRECTION; ROBOTICS; ORIENTATION; SENSORS; SPEED;
D O I
10.1016/j.jneumeth.2017.01.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Functional magnetic resonance imaging is well suited to link neural population activation with movement parameters of complex natural arm movements. However, currently existing MR-compatible arm tracking devices are not constructed to measure arm joint movement parameters of unrestricted movements. Therefore, to date most research focuses on simple arm movements or includes very little knowledge about the actual movement kinematics. New method: We developed a low cost gyroscope-based arm movement tracking system (GAMTS) that features MR-compatibility. The system consists of dual-axis analogue gyroscopes that measure rotations of upper and lower arm joints. After MR artifact reduction, the rotation angles of the individual arm joints are calculated and used to animate a realistic arm model that is implemented in the OpenSim platform. The OpenSim platform can then provide the kinematics of any point on the arm model. Results: In order to demonstrate the capabilities of the system, we first assessed the quality of reconstructed wrist movements in a low-noise environment where typical MR-related problems are absent and finally, we validated the reconstruction in the MR environment. Comparison with existing methods: The system provides the kinematics of the whole arm when natural unrestricted arm movements are performed inside the MR-scanner. Conclusion: The GAMTS is reliably capable of reconstructing the kinematics of trajectories and the reconstruction error is small in comparison with the movement induced variation of speed, displacement, and rotation. Moreover, the system can be used to probe brain areas for their correlation with movement kinematics. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 26
页数:11
相关论文
共 50 条
  • [21] Machine vision based fiber optic joint sensor for MR-compatible robot
    Virtanen, J
    Malila, M
    Louhisalmi, Y
    Hyvärinen, P
    Nevala, K
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 555 - 560
  • [22] A Dual-Mode Readout System for a MR-Compatible Ultrahigh Resolution SPECT/PET System
    Zhang, J. C.
    Cai, L.
    Wang, J. H.
    Shen, Z. M.
    Tang, F. K.
    Meng, L. J.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4196 - 4198
  • [23] Development of a SiPM Based MR-Compatible DOI-TOF-PET Detector
    Furumiya, Tetsuo
    Tsuda, Tomoaki
    Tonami, Hiromichi
    Satoh, Masanobu
    Nakazawa, Masayuki
    Ohi, Junichi
    Kitamura, Keishi
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [24] Optical Fiber-Based MR-Compatible Sensors for Medical Applications: An Overview
    Taffoni, Fabrizio
    Formica, Domenico
    Saccomandi, Paola
    Di Pino, Giovanni
    Schena, Emiliano
    SENSORS, 2013, 13 (10) : 14105 - 14120
  • [25] Initial In Vivo Studies with a Polymer-based MR-compatible Guide Wire
    Mekle, Ralf
    Zenge, Michael O.
    Ladd, Mark E.
    Quick, Harald H.
    Hofmann, Eugen
    Scheffler, Klaus
    Bilecen, Deniz
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (10) : 1384 - 1389
  • [26] PRECISION POSITION TRACKING OF MR-COMPATIBLE PNEUMATIC PISTON-CYLINDER USING SLIDING MODE CONTROL
    Comber, David
    Barth, Eric J.
    PROCEEDINGS OF THE ASME DYNAMIC SYSTEMS AND CONTROL CONFERENCE AND BATH/ASME SYMPOSIUM ON FLUID POWER AND MOTION CONTROL (DSCC 2011), VOL 1, 2012, : 45 - 51
  • [27] Head Motion Tracking for Frameless Stereotactic Radiosurgery Using MR-Compatible 1D Lidar
    Boroomandisorkhabi, B.
    Montazeri, S.
    Kim, T.
    Esmaeelpour, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E775 - E776
  • [28] A GYROSCOPE-BASED SYSTEM FOR LOCATING A POINT SOURCE OF LOW-FREQUENCY ELECTROMAGNETIC RADIATION
    Koruba, Zbigniew
    Tusnio, Janusz
    JOURNAL OF THEORETICAL AND APPLIED MECHANICS, 2009, 47 (02) : 343 - 362
  • [29] A Clinical Validation of the MR-Compatible Delta4 QA System in a 0.35 Tesla MR-Linac
    Desai, V.
    Bayouth, J.
    Smilowitz, J.
    Yadav, P.
    MEDICAL PHYSICS, 2020, 47 (06) : E676 - E676
  • [30] A clinical validation of the MR-compatible Delta4 QA system in a 0.35 tesla MR linear accelerator
    Desai, Vimal
    Bayouth, John
    Smilowitz, Jennifer
    Yadav, Poonam
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (04): : 82 - 91