An MR-compatible gyroscope-based arm movement tracking system

被引:5
|
作者
Shirinbayan, S. Iman [1 ]
Rieger, Jochem W. [1 ]
机构
[1] Carl Von Ossietzky Univ Oldenburg, Dept Psychol, Oldenburg, Germany
关键词
fMRI; Arm movement tracking system; MR-compatibility; analogue gyroscopes; OpenSim platform; FUNCTIONAL-ORGANIZATION; CORTICAL CONTROL; MOTOR CORTEX; DIRECTION; ROBOTICS; ORIENTATION; SENSORS; SPEED;
D O I
10.1016/j.jneumeth.2017.01.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Functional magnetic resonance imaging is well suited to link neural population activation with movement parameters of complex natural arm movements. However, currently existing MR-compatible arm tracking devices are not constructed to measure arm joint movement parameters of unrestricted movements. Therefore, to date most research focuses on simple arm movements or includes very little knowledge about the actual movement kinematics. New method: We developed a low cost gyroscope-based arm movement tracking system (GAMTS) that features MR-compatibility. The system consists of dual-axis analogue gyroscopes that measure rotations of upper and lower arm joints. After MR artifact reduction, the rotation angles of the individual arm joints are calculated and used to animate a realistic arm model that is implemented in the OpenSim platform. The OpenSim platform can then provide the kinematics of any point on the arm model. Results: In order to demonstrate the capabilities of the system, we first assessed the quality of reconstructed wrist movements in a low-noise environment where typical MR-related problems are absent and finally, we validated the reconstruction in the MR environment. Comparison with existing methods: The system provides the kinematics of the whole arm when natural unrestricted arm movements are performed inside the MR-scanner. Conclusion: The GAMTS is reliably capable of reconstructing the kinematics of trajectories and the reconstruction error is small in comparison with the movement induced variation of speed, displacement, and rotation. Moreover, the system can be used to probe brain areas for their correlation with movement kinematics. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 26
页数:11
相关论文
共 50 条
  • [1] MR-compatible endoscopy and tracking for image guided surgery
    Gross, P
    Kitney, RI
    Claesen, S
    Gross, P
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 1044 - 1049
  • [2] Testing an MR-compatible afterloader for MR-based source tracking in MRI guided HDR
    Beld, E.
    Seevinck, P. R.
    Schuurman, J.
    Zijlstra, F.
    Viergever, M. A.
    Lagendijk, J. J. W.
    Moerland, M. A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S141 - S142
  • [3] Dodecapus: An MR-compatible system for somatosensory stimulation
    Huang, Ruey-Song
    Sereno, Martin I.
    NEUROIMAGE, 2007, 34 (03) : 1060 - 1073
  • [4] A general-purpose MR-compatible robotic system
    Tsekos, Nikolaos V.
    Christoforou, Eftychios
    Ozcan, Alpay
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2008, 27 (03): : 51 - 58
  • [5] Actuation System of the MR-compatible Surgical Robot Manipulator
    Seung, Sungmin
    Lee, Joohack
    Kim, Daegwan
    Jeong, Semi
    Cha, Kyungrae
    2018 18TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2018, : 945 - 947
  • [6] A simple and fast system calibration method for MR-compatible OctoSPECT
    Chen, Si
    Meier, Dirk
    Wang, Yuchuan
    Wagenaar, Douglas
    Patt, Bradley
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [7] Gyroscope-based Secure NFC Payment System using Signatures
    Go, Woong
    Ryu, Sungyong
    Kwak, Jin
    INFORMATION-AN INTERNATIONAL INTERDISCIPLINARY JOURNAL, 2012, 15 (05): : 2219 - 2232
  • [8] Development and implementation of an MR-compatible whole body video system
    Neuner, Irene
    Wegener, Peter
    Stoecker, Tony
    Kircher, Tilo
    Schneider, Frank
    Shah, N. Jon
    NEUROSCIENCE LETTERS, 2007, 420 (02) : 122 - 127
  • [9] GantryMate: A Modular MR-Compatible Assistance System for MR-Guided Needle Interventions
    Reichert, Andreas
    Bock, Michael
    Vogele, Michael
    Krafft, Axel Joachim
    TOMOGRAPHY, 2019, 5 (02) : 266 - 273
  • [10] Development of an MR-compatible SPECT system (MRSPECT) for simultaneous data acquisition
    Hamamura, Mark J.
    Ha, Seunghoon
    Roeck, Werner W.
    Muftuler, L. Tugan
    JWagenaar, Douglas
    Meier, Dirk
    Patt, Bradley E.
    Nalcioglu, Orhan
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (06): : 1563 - 1575