摘要
The chemometric method referred to as the generalized rank annihilation method (GRAM) is used to improve the precision, accuracy, and resolution of comprehensive two-dimensional gas chromatography (GC x GC) data. Because GC x GC signals follow a bilinear structure, GC x GC signals can be readily extracted from noise by chemometric techniques such as GRAM. This resulting improvement in signal-to-noise ratio (S/N) and detectability is referred to as bilinear signal enhancement. Here, GRAM uses bilinear signal enhancement on both resolved and unresolved GC x GC peaks that initially have a low SIN in the original GC x GC data. In this work, the chemometric method of GRAM is compared to two traditional peak integration methods for quantifying GC x GC analyte signals, One integration method uses a threshold to determine the signal of a peak of interest. With this integration method only those data points above the limit of detection and within a selected area are integrated to produce the total analyte signal for calibration and quantification. The other integration method evaluated did not employ a threshold, and simply summed all the data points in a selected region to obtain a total analyte signal, Substantial improvements in quantification precision, accuracy, and limit of detection are obtained by using GRAM, as compared to,when either peak integration method is applied. In addition, the GRAM results are found to be more accurate than results obtained by peak integration, because GRAM more effectively corrects for the slight baseline offset remaining after the background subtraction of data. In the case of a 2.7-ppm propylbenzene synthetic sample the quantification result with GRAM is 2.6 times more precise and 4.2 times more accurate than the integration method without a threshold, and 18 times more accurate than the integration method with a threshold. The limit of detection for propylbenzene was 0.6 ppm (parts per million by mass) using GRAM, without implementing any sample preconcentration prior to injection. GRAM is also demonstrated as a means to resolve overlapped signals, while enhancing the S/N. Four alkyl benzene signals of low S/N which were not resolved by GC x GC are mathematically resolved and quantified.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
  • [21] μGC x μGC: Comprehensive Two-Dimensional Gas Chromatographic Separations with Microfabricated Components
    Collin, William R.
    Bondy, Amy
    Paul, Dibyadeep
    Kurabayashi, Katsuo
    Zellers, Edward T.
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (03) : 1630 - 1637
  • [22] Comprehensive two-dimensional GC (GC x GC) qMS analysis of tetrachloronaphthalenes in Halowax formulations
    Lukaszewicz, E.
    Ieda, T.
    Horii, Y.
    Yamashita, N.
    Falandysz, J.
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2007, 42 (11): : 1607 - 1614
  • [23] Proper tuning of comprehensive two-dimensional gas chromatography (GC x GC) to optimize the separation of complex oil fractions
    Beens, J
    Blomberg, J
    Schoenmakers, PJ
    [J]. HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 2000, 23 (03): : 182 - 188
  • [24] Analysis of human breath samples with a multi-bed sorption trap and comprehensive two-dimensional gas chromatography (GC x GC)
    Libardoni, Mark
    Stevens, P. T.
    Waite, J. Hunter
    Sacks, Richard
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 842 (01): : 13 - 21
  • [25] Recent developments in comprehensive two-dimensional gas chromatography (GC x GC) III. Applications for petrochemicals and organohalogens
    Adahchour, M.
    Beens, J.
    Vreuls, R. J. J.
    Brinkman, U. A. Th.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (07) : 726 - 741
  • [26] Quantitative determination of BTEX and total aromatic compounds in gasoline by comprehensive two-dimensional gas chromatography (GC x GC)
    Frysinger, GS
    Gaines, RB
    Ledford, EB
    [J]. HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1999, 22 (04): : 195 - 200
  • [27] Optimization of comprehensive two-dimensional gas-chromatography (GC x GC) mass spectrometry for the determination of essential oils
    Omar, Jone
    Alonso, Bone
    Olivares, Maitane
    Vallejo, Asier
    Etxebarria, Nestor
    [J]. TALANTA, 2012, 88 : 145 - 151
  • [28] Comprehensive two-dimensional gas chromatography (GC x GC) retention time shift correction and modeling using bilinear peak alignment, correlation optimized shifting and multivariate curve resolution
    Parastar, Hadi
    Jalali-Heravi, Mehdi
    Tauler, Roma
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2012, 117 : 80 - 91
  • [29] Quality evaluation of volatile oils of Traditional Chinese Medicines by using comprehensive two-dimensional gas chromatography (GC×GC)
    Chunhai Ruan
    Guowang Xu
    Xin Lu
    Ruixiang Hua
    Hongwei Kong
    Ke Xiao
    Qing Yang
    [J]. Chromatographia, 2003, 57 : S265 - S270
  • [30] Fast comprehensive two-dimensional gas chromatography (GC x GC) using 50-μm ID second-dimension columns
    Adahchour, M
    Tasöz, A
    Beens, J
    Vreuls, RJJ
    Batenburg, AM
    Brinkman, UAT
    [J]. JOURNAL OF SEPARATION SCIENCE, 2003, 26 (9-10) : 753 - 760