Enhancing the limit of detection for comprehensive two-dimensional gas chromatography (GC x GC) using bilinear chemometric analysis

被引:0
|
作者
Fraga, CG [1 ]
Prazen, BJ [1 ]
Synovec, RE [1 ]
机构
[1] Univ Washington, Dept Chem, Ctr Proc Analyt Chem, Seattle, WA 98195 USA
来源
关键词
bilinear signal enhancement; two-dimensional comprehensive gas chromatography; chemometrics; GC; GRAM;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The chemometric method referred to as the generalized rank annihilation method (GRAM) is used to improve the precision, accuracy, and resolution of comprehensive two-dimensional gas chromatography (GC x GC) data. Because GC x GC signals follow a bilinear structure, GC x GC signals can be readily extracted from noise by chemometric techniques such as GRAM. This resulting improvement in signal-to-noise ratio (S/N) and detectability is referred to as bilinear signal enhancement. Here, GRAM uses bilinear signal enhancement on both resolved and unresolved GC x GC peaks that initially have a low SIN in the original GC x GC data. In this work, the chemometric method of GRAM is compared to two traditional peak integration methods for quantifying GC x GC analyte signals, One integration method uses a threshold to determine the signal of a peak of interest. With this integration method only those data points above the limit of detection and within a selected area are integrated to produce the total analyte signal for calibration and quantification. The other integration method evaluated did not employ a threshold, and simply summed all the data points in a selected region to obtain a total analyte signal, Substantial improvements in quantification precision, accuracy, and limit of detection are obtained by using GRAM, as compared to,when either peak integration method is applied. In addition, the GRAM results are found to be more accurate than results obtained by peak integration, because GRAM more effectively corrects for the slight baseline offset remaining after the background subtraction of data. In the case of a 2.7-ppm propylbenzene synthetic sample the quantification result with GRAM is 2.6 times more precise and 4.2 times more accurate than the integration method without a threshold, and 18 times more accurate than the integration method with a threshold. The limit of detection for propylbenzene was 0.6 ppm (parts per million by mass) using GRAM, without implementing any sample preconcentration prior to injection. GRAM is also demonstrated as a means to resolve overlapped signals, while enhancing the S/N. Four alkyl benzene signals of low S/N which were not resolved by GC x GC are mathematically resolved and quantified.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
  • [1] Comprehensive two-dimensional gas chromatography - GC x GC
    Marriott, P
    [J]. JOURNAL OF SEPARATION SCIENCE, 2004, 27 (5-6): : 357 - 357
  • [2] COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY (GC x GC)
    Pedroso, Marcio Pozzobon
    Fonseca de Godoy, Luiz Antonio
    de Vasconcellos Fidelis, Carlos Henrique
    Ferreira, Ernesto Correa
    Poppi, Ronei Jesus
    Augusto, Fabio
    [J]. QUIMICA NOVA, 2009, 32 (02): : 421 - 430
  • [3] The evolution of comprehensive two-dimensional gas chromatography (GC x GC)
    Górecki, T
    Harynuk, J
    Panic, O
    [J]. JOURNAL OF SEPARATION SCIENCE, 2004, 27 (5-6) : 359 - 379
  • [4] Comprehensive two-dimensional gas chromatography (GC x GC) as a diagnostic tool
    Beens, J
    Tijssen, R
    Blomberg, J
    [J]. HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1998, 21 (01): : 63 - 64
  • [5] Recent advances in comprehensive two-dimensional gas chromatography (GC x GC)
    Gorecki, Tadeusz
    Panic, Ognjen
    Oldridge, Nathan
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (7-8) : 1077 - 1104
  • [6] Quantitative aspects of comprehensive two-dimensional gas chromatography (GC x GC)
    Beens, J
    Boelens, H
    Tijssen, R
    Blomberg, J
    [J]. HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1998, 21 (01): : 47 - 54
  • [7] Advances in comprehensive two-dimensional gas chromatography (GC×GC)
    Eiserbeck, Christiane
    Nelson, Robert K.
    Reddy, Christopher M.
    Grice, Kliti
    [J]. RSC Detection Science, 2015, 2015-January (04): : 324 - 365
  • [8] Comprehensive two-dimensional gas chromatography (GC×GC) in environmental analysis and monitoring
    Ognjen Pani
    Tadeusz Górecki
    [J]. Analytical and Bioanalytical Chemistry, 2006, 386 : 1013 - 1023
  • [9] Comprehensive two-dimensional gas chromatography with mass spectrometric detection (GC x GC/MS) applied to the analysis of petroleum
    Frysinger, GS
    Gaines, RB
    [J]. HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1999, 22 (05): : 251 - 255
  • [10] Application of comprehensive two-dimensional gas chromatography (GC x GC) to the enantioselective analysis of essential oils
    Shellie, R
    Marriott, P
    Cornwell, C
    [J]. JOURNAL OF SEPARATION SCIENCE, 2001, 24 (10-11) : 823 - 830