共 8 条
Absorbed organ and effective doses from digital intra-oral and panoramic radiography applying the ICRP 103 recommendations for effective dose estimations
被引:48
|作者:
Granlund, Christina
[1
]
Thilander-Klang, Anne
[2
,3
]
Ylhan, Betul
[4
]
Lofthag-Hansen, Sara
[5
]
Ekestubbe, Annika
[1
]
机构:
[1] Univ Gothenburg, Sahlgrenska Acad, Inst Odontol, Dept Oral & Maxillofacial Radiol, Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
[4] Ege Univ, Dept Oral & Maxillofacial Radiol, Fac Dent, Izmir, Turkey
[5] Publ Dent Hlth Serv, Clin Oral & Maxillofacial Radiol, Gothenburg, Sweden
来源:
关键词:
RISK;
REDUCTION;
RADIATION;
EXPOSURE;
TUMORS;
D O I:
10.1259/bjr.20151052
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Objective: During dental radiography, the salivary and thyroid glands are at radiation risk. In 2007, the International Commission on Radiological Protection (ICRP) updated the methodology for determining the effective dose, and the salivary glands were assigned tissue-specific weighting factors for the first time. The aims of this study were to determine the absorbed dose to the organs and to calculate, applying the ICRP publication 103 tissue-weighting factors, the effective doses delivered during digital intraoral and panoramic radiography. Methods: Thermoluminescent dosemeter measurements were performed on an anthropomorphic head and neck phantom. The organ-absorbed doses were measured at 30 locations, representing different radiosensitive organs in the head and neck, and the effective dose was calculated according to the ICRP recommendations. Results: The salivary glands and the oral mucosa received the highest absorbed doses from both intraoral and panoramic radiography. The effective dose from a fullmouth intraoral examination was 15mSv and for panoramic radiography, the effective dose was in the range of 19-75 mSv, depending on the panoramic equipment used. Conclusion: The effective dose from a full-mouth intraoral examination is lower and that frompanoramic radiography is higher than previously reported. Clinicians should be aware of the higher effective dose delivered during panoramic radiography and the risk-benefit profile of this technique must be assessed for the individual patient. Advances in knowledge: The effective dose of radiation from panoramic radiography is higher than previously reported and there is large variability in the delivered radiation dosage among the different types of equipment used.
引用
收藏
页数:9
相关论文