Effective doses from panoramic radiography and CBCT (cone beam CT) using dose area product (DAP) in dentistry

被引:51
|
作者
Shin, H. S. [1 ]
Nam, K. C. [2 ]
Park, H. [1 ,3 ]
Choi, H. U. [1 ]
Kim, H. Y. [1 ]
Park, C. S. [1 ,3 ]
机构
[1] Yonsei Univ, Dent Hosp, Dept Oral & Maxillofacial Radiol, Seoul 120749, South Korea
[2] Dongguk Univ, Dept Med Engn, Coll Med, Goyang, South Korea
[3] Yonsei Univ, Coll Dent, Dept Oral & Maxillofacial Radiol, Seoul 120749, South Korea
关键词
CBCT (cone beam CT); effective dose; ICRP; DAP (dose area product); conversion factor; DOSIMETRY; DEVICES;
D O I
10.1259/dmfr.20130439
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: We compared the effective dose from panoramic radiography with that from cone beam CT (CBCT) using dose area product under adult and child exposure conditions. Methods: The effective doses of the cephalo, panorama, implant and dental modes of Alphard 3030 (Asahi Roentgen Ind., Co. Ltd, Kyoto, Japan) CBCT and the Jaw, Wide, Facial and temporomandibular joint modes of Rayscan Symphony (RAY Co., Ltd, Hwaseong, Republic of Korea) CBCT were compared with those of CRANEX (R) 3+ CEPH (Soredex Orion Corporation, Helsinki, Finland) panoramic radiography equipment under adult and child exposure conditions. Each effective dose was calculated using a conversion formula from dose area product meter measured values (VacuTec Messtechnik GmbH, Dresden, Germany). The conversion formulae used were suggested by Helmrot and Alm Carlsson and Batista et al, and they were applied with the tube voltage taken into consideration. Results: The maximum effective doses from the Alphard 3030 and Rayscan Symphony were 67 and 21 times greater than that from panoramic radiography, respectively. The ratios of the effective dose under the child setting to that under the adult condition were 0.60-0.62 and 0.84-0.95, and the maximum differences in effective doses between the adult and child exposure settings were equivalent to 27 and 4 times greater than a panoramic examination in the Alphard 3030 and Rayscan Symphony, respectively. Conclusions: The effective CBCT doses were higher than those of panoramic radiography. The differences in effective doses between the adult and child CBCT settings were dependent on equipment type and exposure parameters. Therefore, adequate mode selection and control of exposure as well as further research are necessary to minimize the effective dose to patients, especially for radiosensitive children.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Using GafChromic film to estimate the effective dose from dental cone beam CT and panoramic radiography
    Al-Okshi, A.
    Nilsson, M.
    Petersson, A.
    Wiese, M.
    Lindh, C.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (07)
  • [2] Effective dose from cone beam CT examinations in dentistry
    Roberts, J. A.
    Drage, N. A.
    Davies, J.
    Thomas, D. W.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (973): : 35 - 40
  • [3] Comparing Effective Doses for Hip Imaging Using Cone Beam CT (CBCT) and Multidetector CT (MDCT)
    Dave, J.
    Jiang, X.
    Machado, P.
    Roth, C.
    Minch, T.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E629 - E629
  • [4] Influence of beam width of cone beam CT (CBCT) scan on effective dose
    Abuhaimed, A.
    Martin, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1538 - S1539
  • [5] Determination of dose-area product from panoramic radiography using a pencil ionization chamber: Normalized data for the estimation of patient effective and organ doses
    Perisinakis, K
    Damilakis, J
    Neratzoulakis, J
    Gourtsoyiannis, N
    [J]. MEDICAL PHYSICS, 2004, 31 (04) : 708 - 714
  • [6] Effective dose of cone beam CT (CBCT) of the facial skeleton: a systematic review
    Al-Okshi, A.
    Lindh, C.
    Sale, H.
    Gunnarsson, M.
    Rohlin, M.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1045):
  • [7] Effective doses from cone beam CT investigation of the jaws
    Davies, J.
    Johnson, B.
    Drage, N. A.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (01) : 30 - 36
  • [8] Strategies for Evaluation of Daily Delivered Dose Using Cone Beam CT (CBCT)
    Tuohy, R.
    Bosse, C.
    Mavroidis, P.
    Zheng, S.
    Richard, C.
    Gutierrez, A.
    Papanikolaou, N.
    Stathakis, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S883 - S883
  • [9] Dose indices in dental cone beam CT and correlation with dose-area product
    Araki, K.
    Patil, S.
    Endo, A.
    Okano, T.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
  • [10] Effective Doses for Extremity Imaging Using Cone Beam CT Scanners
    Dave, J.
    Minch, T.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E631 - E631