Effective dose from cone beam CT examinations in dentistry

被引:238
|
作者
Roberts, J. A. [1 ]
Drage, N. A. [2 ]
Davies, J. [3 ]
Thomas, D. W. [1 ]
机构
[1] Velindre NHS Trust, Dept Med Phys, Velindre Canc Ctr, Cardiff, S Glam, Wales
[2] Univ Dent Hosp, Cardiff & Vale NHS Trust, Dept Dent Radiol, Cardiff, S Glam, Wales
[3] Guys Hosp, Dept Dent Radiol Imaging, London SE1 9RT, England
来源
BRITISH JOURNAL OF RADIOLOGY | 2009年 / 82卷 / 973期
关键词
DIGITAL VOLUME TOMOGRAPHY; COMPUTED-TOMOGRAPHY; ORTHOGNATHIC SURGERY; DOSIMETRY; DEVICES;
D O I
10.1259/bjr/31419627
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cone beam CT (CBCT) is becoming an increasingly utilized imaging modality for dental examinations in the UK. Previous studies have presented little information on patient dose for the range of fields of view (FOVs) that can be utilized. The purpose of the study was therefore to calculate the effective dose delivered to the patient during a selection of CBCT examinations performed in dentistry. in particular, the i-CAT CBCT scanner was investigated for several imaging protocols commonly used in clinical practice. A Rando phantom containing thermoluminescent dosemeters was scanned. Using both the 1990 and recently approved 2007 International Commission on Radiological Protection recommended tissue weighting factors, effective doses were calculated. The doses (E(1990), E(2007)) were: full FOV head (92.8 mu Sv, 206.2 mu Sv); 13 cm scan of the jaws (39.5 mu Sv, 133.9 mu Sv); 6 cm high-resolution mandible (47.2 mu Sv, 188.5 mu Sv); 6 cm high-resolution maxilla (18.5 mu Sv, 93.3 mu Sv); 6 cm standard mandible (23.9 mu Sv, 96.2 mu Sv); and 6 cm standard maxilla (9.7 mu Sv, 58.9 mu Sv). The doses from CBCT are low compared with conventional CT but significantly higher than conventional dental radiography techniques.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 50 条
  • [1] Evaluation of the effective dose of cone beam CT and multislice CT for temporomandibular joint examinations at optimized exposure levels
    Kadesjo, N.
    Benchimol, D.
    Falahat, B.
    Nasstrom, K.
    Shi, X-Q
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (08)
  • [2] Effective doses from panoramic radiography and CBCT (cone beam CT) using dose area product (DAP) in dentistry
    Shin, H. S.
    Nam, K. C.
    Park, H.
    Choi, H. U.
    Kim, H. Y.
    Park, C. S.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (05)
  • [3] Dose optimization for assessment of periodontal structures in cone beam CT examinations
    Al-Okshi, Ayman
    Theodorakou, Chrysoula
    Lindh, Christina
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (03)
  • [4] Dose assessment of cone beam CT imaging protocols as part of SPECT/CT examinations
    Tonkopi, E.
    Ross, A. A.
    [J]. MEDICAL PHYSICS, 2014, 41 (08) : 7 - 8
  • [5] Influence of beam width of cone beam CT (CBCT) scan on effective dose
    Abuhaimed, A.
    Martin, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1538 - S1539
  • [6] Optimizing effective dose and image quality in cone beam CT sialography
    Douglas, Danielle J.
    Perschbacher, Susanne E.
    Moayedi, Massieh
    Lam, Ernest W. N.
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2023, 135 (05): : 686 - 697
  • [7] Study of effective dose of various protocols in equipment cone beam CT
    Soares, Maria Rosangela
    Batista, Wilson Otto
    Antonio, Patricia de lara
    Caldas, Linda V. E.
    Maia, Ana F.
    [J]. APPLIED RADIATION AND ISOTOPES, 2015, 100 : 21 - 26
  • [8] Conversion coefficients for the estimation of effective dose in cone-beam CT
    Kim, Dong-Soo
    Rashsuren, Oyuntugs
    Kim, Eun-Kyung
    [J]. IMAGING SCIENCE IN DENTISTRY, 2014, 44 (01) : 21 - 29
  • [9] Effective dose span of ten different cone beam CT devices
    Rottke, D.
    Patzelt, S.
    Poxleitner, P.
    Schulze, D.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (07)
  • [10] Validation of a Monte Carlo simulation for dose assessment in dental cone beam CT examinations
    Morant, J. J.
    Salvado, M.
    Casanovas, R.
    Hernandez-Giron, I.
    Velasco, E.
    Calzado, A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (03): : 200 - 209