Full-Matrix Phase Shift Migration Method for Transcranial Ultrasonic Imaging

被引:37
|
作者
Jiang, Chen [1 ]
Li, Ying [1 ]
Xu, Kailiang [1 ]
Ta, Dean [1 ,2 ]
机构
[1] Fudan Univ, Dept Elect Engn, Shanghai 200433, Peoples R China
[2] Fudan Univ, Acad Engn & Technol, Shanghai 200433, Peoples R China
关键词
Phase correction; spectrum-domain method; transcranial ultrasound imaging; TIME-REVERSAL; ABERRATION CORRECTION; SIMULATION; SCATTERING; ARRAYS; BRAIN;
D O I
10.1109/TUFFC.2020.3016382
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A spectrum-domainmethod, called full-matrix phase shift migration (FM-PSM), is presented for transcranial ultrasound phase correction and imaging with ideal synthetic aperture focusing technology. The simulated data obtained using the pseudospectral time-domainmethod are used to evaluate the feasibility of the method. The experimental data measured from a 3-D printed skull phantom are used to evaluate the algorithm performance in terms of resolution, contrast-to-noise ratio (CNR), and eccentricity comparing with the classical ray-tracing delay and sum (DAS) method. In wire imaging experiment, FM-PSM has a lateral resolution of 0.22 mm and ray-tracing DAS has a lateral resolution of 0.24mm measured at -6-dB drop using a transducer with a center frequency of 6.25 MHz. In cylinder imaging experiment, FM-PSM has a CNR of 2.14 and ray-tracing DAS has a CNR of 1.82, which illustrates about 17% improvement. For a J- element array and an output image with pixels M xN (lateral x axial), the computational cost of the DAS is of O(J x M-2 x N-2); on the contrary, it reduces to O(J x M x N-2) with the proposed FM-PSM. The results suggest that FM-PSM is an efficiency method for transcranial ultrasonic imaging.
引用
收藏
页码:72 / 83
页数:12
相关论文
共 50 条
  • [41] AN ULTRASONIC METHOD OF CONSTRUCTING A DIFFERENTIAL PHASE-SHIFT KEYING SYSTEM
    IKEDA, T
    UCHIDA, T
    TODA, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1992, 31 : 201 - 203
  • [42] Full Matrix Capture and Total Focusing Method: The Next Evolution in Ultrasonic Testing
    Caulder, Alan
    MATERIALS EVALUATION, 2018, 76 (05) : 591 - 597
  • [43] Ultrasonic breast imaging using a wave-equation migration method
    Huang, LJ
    Duric, N
    Littrup, P
    MEDICAL IMAGING 2003: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2003, 5035 : 432 - 439
  • [44] Ultrasonic phased array phase shift migration imaging of irregular surface components using attenuation compensation and anti-aliasing technique
    Wu, Juncen
    Hu, Hongwei
    Song, Yongfeng
    Lyu, Duo
    Li, Xiongbing
    NDT & E INTERNATIONAL, 2023, 133
  • [45] Current Stress Optimization Method of Full-phase-shift Dual-active Full-bridge DC Converter Based on Matrix Transformer
    Wu C.
    Chen X.
    Li Z.
    Wang F.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (09): : 3550 - 3562
  • [46] Phased array ultrasonic imaging using angle beam virtual source full matrix capture-total focusing method
    Sumana
    Kumar, Anish
    NDT & E INTERNATIONAL, 2020, 116 (116)
  • [47] ACCURATE DEPTH MIGRATION BY A GENERALIZED PHASE-SHIFT METHOD - DISCUSSION
    PAI, DM
    GEOPHYSICS, 1989, 54 (02) : 271 - 272
  • [48] Computationally Efficient Phase Shift Plus Interpolation Seismic Migration Method
    Mousa, Wail A.
    Al-Battal, Abdullah E.
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2020, 17 (05) : 775 - 778
  • [49] Implementation of the Phase Shift Migration in MIMO-Sidelooking Imaging at Terahertz Band
    Gao, Hang
    Li, Chao
    Zheng, Shen
    Wu, Shiyou
    Fang, Guangyou
    IEEE SENSORS JOURNAL, 2019, 19 (20) : 9384 - 9393
  • [50] Phase shift migration based plane-wave imaging of cortical bone
    Zhang, Yun-Yun
    Li, Yi-Fang
    Shi, Qin-Zhen
    Xu, Le-Xiu
    Dai, Fei
    Xing, Wen-Yu
    Ta, De-An
    ACTA PHYSICA SINICA, 2023, 72 (15)