Cerebral foreign body reaction due to hydrophilic polymer embolization following aneurysm treatment by pipeline flow diversion device

被引:10
|
作者
Geisbush, Thomas Rand [1 ]
Marks, Michael P. [2 ]
Heit, Jeremy J. [2 ]
机构
[1] Rosalind Franklin Univ Med & Sci, Chicago Med Sch, Chicago, IL USA
[2] Stanford Hosp & Clin, 300 Pasteur Dr,Room S-047, Stanford, CA 94305 USA
关键词
Granulomatous inflammation; foreign body reaction; hydrophilic polymer embolization; flow diverting stent; cerebral aneurysm; ENDOVASCULAR TREATMENT; COMPLICATIONS;
D O I
10.1177/1591019919830767
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The use of flow diverting stents for wide based, intracranial aneurysms has become an invaluable treatment option. While intracranial hemorrhage and ischemic stroke from dislodged atherosclerotic emboli are common adverse events, the potential for delayed granulomatous inflammation from possible hydrophilic polymer emboli is rarely recognized. We present a unique case in which visible chipping of the pusher wire for stent placement was observed, followed by clinical and radiographic evidence suggestive of a delayed foreign body reaction to intracranial hydrophilic polymer emboli. A 55-year-old woman underwent placement of a Pipeline embolization device for a left-sided, broad-based aneurysm at the base of the internal carotid artery and posterior communicating artery. Two months later she developed right-sided focal neurological deficits. Imaging showed ipsilateral focal edema and enhancing lesions with contrast. Although not confirmed with biopsy and histopathology, clinical and radiographic evidence suggests that this patient probably experienced a delayed foreign body reaction to hydrophilic polymer emboli from compromised procedural equipment during flow diverting stent placement. Although previously described, this is the first instance to our knowledge in whichvisible chipping of the pusher wire was observed on a Pipeline embolization device.
引用
收藏
页码:447 / 453
页数:7
相关论文
共 43 条
  • [21] Malignant stroke in a ticagrelor non-responder as a complication following aneurysm treatment with the Pipeline Embolization Device™
    Ghamasaee, Pegah
    Carr, Kevin
    Johnson, Jeremiah
    Grandhi, Ramesh
    INTERVENTIONAL NEURORADIOLOGY, 2017, 23 (03) : 297 - 300
  • [22] Endovascular Treatment of Middle Cerebral Artery Aneurysms with Flow Modification with the Use of the Pipeline Embolization Device
    Yavuz, K.
    Geyik, S.
    Saatci, I.
    Cekirge, H. S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (03) : 529 - 535
  • [23] Focal, transient mechanical narrowing of a pipeline embolization device following treatment of an internal carotid artery aneurysm (Reprinted)
    Miller, Timothy Ryan
    Jindal, Gaurav
    Gandhi, Dheeraj
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (10) : e35
  • [24] Pipeline embolization device diameter is an important factor determining the efficacy of flow diversion treatment of small intracranial saccular aneurysms
    Kole, Matthew James
    Miller, Timothy Ryan
    Cannarsa, Gregory
    Wessell, Aaron
    Jones, Salazar
    Le, Elizabeth
    Jindal, Gaurav
    Aldrich, Francois
    Simard, J. Marc
    Gandhi, Dheeraj
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (10) : 1004 - +
  • [25] Ischemic Toe Ulceration Due to Foreign Body Embolus From Hydrophilic Polymer-Coated Intravascular Device
    French, Bryce
    Ranguelov, Rostislav
    Johansen, Kaj
    Tan, Swee Lian
    VASCULAR AND ENDOVASCULAR SURGERY, 2019, 53 (07) : 606 - 608
  • [26] Double-barrel Y-configuration Stenting for Flow Diversion of a Giant Recurrent Basilar Apex Aneurysm with the Pipeline Flex Embolization Device
    Ding, Dale
    Starke, Robert M.
    McGuinness, Ben
    Brew, Stefan
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2016, 7 (05) : S99 - S102
  • [27] Suspected cerebral foreign body granuloma following endovascular treatment of intracranial aneurysm: imaging features
    Minks, David
    Briley, Dennis
    Schulz, Ursula
    Kueker, Wilhelm
    NEURORADIOLOGY, 2015, 57 (01) : 71 - 73
  • [28] Suspected cerebral foreign body granuloma following endovascular treatment of intracranial aneurysm: imaging features
    David Minks
    Dennis Briley
    Ursula Schulz
    Wilhelm Küker
    Neuroradiology, 2015, 57 : 71 - 73
  • [29] Age-related outcomes following intracranial aneurysm treatment with the Pipeline Embolization Device: a subgroup analysis of the IntrePED registry
    Brinjikji, Waleed
    Kallmes, David F.
    Cloft, Harry J.
    Lanzino, Giuseppe
    JOURNAL OF NEUROSURGERY, 2016, 124 (06) : 1726 - 1730
  • [30] Small and Medium-Sized Aneurysm Outcomes Following Intracranial Aneurysm Treatment Using the Pipeline Embolization Device: A Subgroup Analysis of the PLUS Registry
    Zhang, Hongyun
    Li, Li
    Zhang, Hongqi
    Liu, Jianmin
    Song, Donglei
    Zhao, Yuanli
    Guan, Sheng
    Maimaitili, Aisha
    Wang, Yunyan
    Feng, Wenfeng
    Wang, Yang
    Wan, Jieqing
    Mao, Guohua
    Shi, Huaizhang
    Luo, Bin
    Shao, Qiuji
    Chang, Kaitao
    Zhang, Qianqian
    He, Yingkun
    Zhang, Peng
    Yang, Xinjian
    Li, Tian xiao
    FRONTIERS IN NEUROLOGY, 2022, 13