Ultrahigh resolution optical coherence tomography imaging with a broadband superluminescent diode light source

被引:117
|
作者
Ko, TH
Adler, DC
Fujimoto, JG
Mamedov, D
Prokhorov, V
Shidlovski, V
Yakubovich, S
机构
[1] MIT, Dept Elect Engn & Comp Sci, Elect Res Lab, Cambridge, MA 02139 USA
[2] Superlum Diodes Ltd, Moscow 117454, Russia
来源
OPTICS EXPRESS | 2004年 / 12卷 / 10期
关键词
D O I
10.1364/OPEX.12.002112
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Ultrahigh resolution optical coherence tomography imaging is performed with a compact broadband superluminescent diode light source. The source consists of two multiplexed broadband superluminescent diodes and has a power output of 4 mW with a spectral bandwidth of 155 nm, centered at a wavelength of 890 nm. In vivo imaging was performed with approximately 2.3 mum axial resolution in scattering tissue and approximately 3.2 mum axial resolution in the retina. These results demonstrate that it is possible to perform in vivo ultrahigh resolution optical coherence tomography imaging using a superluminescent diode light source that is inexpensive, compact, and easy to operate. (C) 2004 Optical Society of America.
引用
收藏
页码:2112 / 2119
页数:8
相关论文
共 50 条
  • [31] Effect of tissue preservation on imaging using ultrahigh resolution optical coherence tomography
    Hsiung, PL
    Nambiar, PR
    Fujimoto, JG
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (06)
  • [32] Ultrahigh resolution optical coherence tomography imaging of architectural morphology in retinal diseases
    Ko, TH
    Fujimoto, JG
    Duker, JS
    Paunescu, LA
    Chan, A
    Drexler, W
    Rogers, AH
    Baumal, CR
    Reichel, E
    Schuman, JS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U50 - U50
  • [33] Comparison of ultrahigh resolution and standard optical coherence tomography for imaging retinal pathologies
    Ko, TH
    Schuman, JS
    Fujimoto, JG
    Paunescu, LA
    Kowalevicz, AM
    Hartl, I
    Drexler, W
    Duker, J
    Wollstein, G
    Ishikawa, H
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U217 - U217
  • [34] Ultrahigh resolution endoscopic optical coherence tomography: a novel technology for gastrointestinal imaging
    Mashimo, H
    Desai, S
    Pedrosa, M
    Wagh, M
    Chen, Y
    Herz, P
    Hsiung, PL
    Aguirre, A
    Koski, A
    Schmitt, J
    Fujimoto, JG
    [J]. GASTROENTEROLOGY, 2005, 128 (04) : A251 - A251
  • [35] Volumetric retinal imaging with ultrahigh-resolution spectral-domain optical coherence tomography and adaptive optics using two broadband light sources
    Cense, Barry
    Koperda, Eric
    Brown, Jeffrey M.
    Kocaoglu, Omer P.
    Gao, Weihua
    Jonnal, Ravi S.
    Miller, Donald T.
    [J]. OPTICS EXPRESS, 2009, 17 (05): : 4095 - 4111
  • [36] A combined multiple-SLED broadband light source at 1300 nm for high resolution optical coherence tomography
    Wang, Hui
    Jenkins, Michael W.
    Rollins, Andrew M.
    [J]. OPTICS COMMUNICATIONS, 2008, 281 (07) : 1896 - 1900
  • [37] Real spectral-domain optical coherence tomography using a superluminescent diode
    Kim, J
    Choi, C
    Soh, KS
    Ho, DS
    Kim, BM
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2005, 47 (02) : 375 - 379
  • [38] Superluminescent diodes for optical coherence tomography
    Shidlovski, V
    Wei, J
    [J]. TEST AND MEASUREMENT APPLICATIONS OF OPTOELECTRONIC DEVICES, 2002, 4648 : 139 - 147
  • [39] Ultrahigh resolution optical biopsy with endoscopic optical coherence tomography
    Herz, PR
    Chen, Y
    Aguirre, AD
    Fujimoto, JG
    Mashimo, H
    Schmitt, J
    Koski, A
    Goodnow, J
    Petersen, C
    [J]. OPTICS EXPRESS, 2004, 12 (15): : 3532 - 3542
  • [40] Ultrahigh-resolution optical coherence tomography with a fiber laser source at 1 μm
    Lim, H
    Jiang, Y
    Wang, YM
    Huang, YC
    Chen, ZP
    Wise, FW
    [J]. OPTICS LETTERS, 2005, 30 (10) : 1171 - 1173