Hydrophilic interaction chromatography versus reversed phase liquid chromatography coupled to mass spectrometry: Effect of electrospray ionization source geometry on sensitivity

被引:47
|
作者
Periat, Aurelie [1 ]
Kohler, Isabelle [1 ]
Bugey, Aurelie [2 ]
Bieri, Stefan [2 ]
Versace, Francois [3 ]
Staub, Christian [1 ,3 ]
Guillarme, Davy [1 ]
机构
[1] Univ Geneva, Univ Lausanne, Sch Pharmaceut Sci, CH-1211 Geneva 4, Switzerland
[2] Off Food Control Author & Vet Affairs Geneva, CH-1211 Geneva 4, Switzerland
[3] Univ Ctr Legal Med, Forens Toxicol & Chem Unit, CH-1211 Geneva 4, Switzerland
关键词
Hydrophilic interaction chromatography; HILIC-MS; Sensitivity; Electrospray ionization; Source geometry; ESI; SILICA COLUMNS; MOBILE PHASES; SOURCE DESIGN; FUNDAMENTALS; SELECTIVITY; ADVANTAGES; ANALYTES; PLASMA; MS/MS;
D O I
10.1016/j.chroma.2014.06.066
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, the influence of electrospray ionization (ESI) source design on the overall sensitivity achieved in hydrophilic interaction chromatography (HILIC) and reversed phase liquid chromatography (RPLC), was investigated. State-of-the-art triple quadrupole mass analyzers from AB Sciex, Agilent Technologies and Waters equipped with brand specific source geometries were tested with various mobile phase pH on 53 pharmaceutical compounds. The design of the ESI source showed to strongly influence the gain in sensitivity that can be achieved in HILIC compared to RPLC mode. The 6460 Triple Quadrupole LC/MS system from AgilentTechnologies was particularly affected by mobile phase settings. Indeed, compared to RPLC conditions, 92% of the compounds had an increased signal-to-noise ratio at a flow rate of 300 mu L/min in HILIC mode at pH 6, while this percentage dropped to only 7% at 1000 mu L/min and pH 3. In contrast, the influence of flow rate and mobile phase pH on the gain in sensitivity between RPLC and HILIC was found very limited with the API 5000 (TM) LC/MS/MS system from AB Sciex, as only 15 to 36% of the tested compounds showed an enhanced sensitivity in HILIC mode. With the Xevo TQ-S instrument from Waters, superior sensitivity in HILIC was noticed for 85% of the compounds with optimal conditions (i.e., pH 3 and 1000 mu L/min), whereas at sub-optimal conditions (i.e. pH 6 and 300 mu L/min), it represented less than 50%. The gain in sensitivity observed in HILIC was found less significant with the recent LC-MS platforms used in this study than for old-generation instruments. Indeed, the improved ESI sources equipping the recent mass analyzers allow for enhanced evaporation efficiency, mainly for RPLC mobile phases containing high proportion of water and this even at high flow rates. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 50 条
  • [21] IMPURITY PROFILING OF DIRITHROMYCIN BY LIQUID CHROMATOGRAPHY COUPLED TO ELECTROSPRAY IONIZATION MASS SPECTROMETRY
    Van den Bossche, Larissa
    Blanchaert, Bart
    Van Schepdael, Ann
    Hoogmartens, Jos
    Adams, Erwin
    ANALYTICAL LETTERS, 2012, 45 (09) : 1058 - 1069
  • [22] Systematic evaluation of acetone and acetonitrile for use in hydrophilic interaction liquid chromatography coupled with electrospray ionization mass spectrometry of basic small molecules
    Heaton, James
    Jones, Michael D.
    Legido-Quigley, Cristina
    Plumb, Robert S.
    Smith, Norman W.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (24) : 3666 - 3674
  • [23] Hydrophilic interaction chromatography coupled to electrospray mass spectrometry for the separation of peptides and protein digests
    Yang, Yuanzhong
    Boysen, Reinhard I.
    Hearn, Milton T. W.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (29) : 5518 - 5524
  • [24] Discrepancies in determination of biogenic amines in beer samples by reversed phase and hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry
    Nalazek-Rudnicka, Katarzyna
    Kubica, Pawel
    Wasik, Andrzej
    MICROCHEMICAL JOURNAL, 2020, 159
  • [25] Analysis of oligonucleotides by ion-pair reversed-phase liquid chromatography coupled with positive mode electrospray ionization mass spectrometry
    Guofeng Weng
    Binwen Sun
    Zheyi Liu
    Fangjun Wang
    Yuanjiang Pan
    Analytical and Bioanalytical Chemistry, 2019, 411 : 4167 - 4173
  • [26] Analysis of oligonucleotides by ion-pair reversed-phase liquid chromatography coupled with positive mode electrospray ionization mass spectrometry
    Weng, Guofeng
    Sun, Binwen
    Liu, Zheyi
    Wang, Fangjun
    Pan, Yuanjiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (18) : 4167 - 4173
  • [27] Hydrophilic interaction chromatography/electrospray ionization mass spectrometry for determination of allantoin in human biological samples
    Iwasaki, Y
    Inoue, K
    Ito, R
    Yoshimura, Y
    Saito, K
    Nakazawa, H
    BUNSEKI KAGAKU, 2005, 54 (02) : 135 - 142
  • [28] Simultaneous determination of six alkaloids in blood and urine using a hydrophilic interaction liquid chromatography method coupled with electrospray ionization tandem mass spectrometry
    Wu, Ximei
    Huang, Weixiong
    Lu, Lin
    Lin, Li
    Yang, Xingfen
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (03) : 1319 - 1327
  • [29] Simultaneous determination of six alkaloids in blood and urine using a hydrophilic interaction liquid chromatography method coupled with electrospray ionization tandem mass spectrometry
    Ximei Wu
    Weixiong Huang
    Lin Lu
    Li Lin
    Xingfen Yang
    Analytical and Bioanalytical Chemistry, 2010, 398 : 1319 - 1327
  • [30] Quantifying tetrapeptide SS-20 in rat plasma using hydrophilic interaction liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Zhan, Yan
    Chen, Xiaoyan
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (30): : 3353 - 3359