Hydrophilic interaction chromatography versus reversed phase liquid chromatography coupled to mass spectrometry: Effect of electrospray ionization source geometry on sensitivity

被引:47
|
作者
Periat, Aurelie [1 ]
Kohler, Isabelle [1 ]
Bugey, Aurelie [2 ]
Bieri, Stefan [2 ]
Versace, Francois [3 ]
Staub, Christian [1 ,3 ]
Guillarme, Davy [1 ]
机构
[1] Univ Geneva, Univ Lausanne, Sch Pharmaceut Sci, CH-1211 Geneva 4, Switzerland
[2] Off Food Control Author & Vet Affairs Geneva, CH-1211 Geneva 4, Switzerland
[3] Univ Ctr Legal Med, Forens Toxicol & Chem Unit, CH-1211 Geneva 4, Switzerland
关键词
Hydrophilic interaction chromatography; HILIC-MS; Sensitivity; Electrospray ionization; Source geometry; ESI; SILICA COLUMNS; MOBILE PHASES; SOURCE DESIGN; FUNDAMENTALS; SELECTIVITY; ADVANTAGES; ANALYTES; PLASMA; MS/MS;
D O I
10.1016/j.chroma.2014.06.066
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, the influence of electrospray ionization (ESI) source design on the overall sensitivity achieved in hydrophilic interaction chromatography (HILIC) and reversed phase liquid chromatography (RPLC), was investigated. State-of-the-art triple quadrupole mass analyzers from AB Sciex, Agilent Technologies and Waters equipped with brand specific source geometries were tested with various mobile phase pH on 53 pharmaceutical compounds. The design of the ESI source showed to strongly influence the gain in sensitivity that can be achieved in HILIC compared to RPLC mode. The 6460 Triple Quadrupole LC/MS system from AgilentTechnologies was particularly affected by mobile phase settings. Indeed, compared to RPLC conditions, 92% of the compounds had an increased signal-to-noise ratio at a flow rate of 300 mu L/min in HILIC mode at pH 6, while this percentage dropped to only 7% at 1000 mu L/min and pH 3. In contrast, the influence of flow rate and mobile phase pH on the gain in sensitivity between RPLC and HILIC was found very limited with the API 5000 (TM) LC/MS/MS system from AB Sciex, as only 15 to 36% of the tested compounds showed an enhanced sensitivity in HILIC mode. With the Xevo TQ-S instrument from Waters, superior sensitivity in HILIC was noticed for 85% of the compounds with optimal conditions (i.e., pH 3 and 1000 mu L/min), whereas at sub-optimal conditions (i.e. pH 6 and 300 mu L/min), it represented less than 50%. The gain in sensitivity observed in HILIC was found less significant with the recent LC-MS platforms used in this study than for old-generation instruments. Indeed, the improved ESI sources equipping the recent mass analyzers allow for enhanced evaporation efficiency, mainly for RPLC mobile phases containing high proportion of water and this even at high flow rates. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 50 条
  • [1] Systematic comparison of sensitivity between hydrophilic interaction liquid chromatography and reversed phase liquid chromatography coupled with mass spectrometry
    Periat, Aurelie
    Boccard, Julien
    Veuthey, Jean-Luc
    Rudaz, Serge
    Guillarme, Davy
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1312 : 49 - 57
  • [2] Systematic evaluation of matrix effects in hydrophilic interaction chromatography versus reversed phase liquid chromatography coupled to mass spectrometry
    Periat, Aurelie
    Kohler, Isabelle
    Thomas, Aurelien
    Nicoli, Raul
    Boccard, Julien
    Veuthey, Jean-Luc
    Schappler, Julie
    Guillarme, Davy
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1439 : 42 - 53
  • [3] Analysis of oligonucleotides by hydrophilic interaction liquid chromatography coupled to negative ion electrospray ionization mass spectrometry
    Gong, Lingzhi
    McCullagh, James S. O.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (32) : 5480 - 5486
  • [4] Plasma lipid analysis by hydrophilic interaction liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Sonomura, Kazuhiro
    Kudoh, Shinobu
    Sato, Taka-Aki
    Matsuda, Fumihiko
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (12) : 2033 - 2037
  • [5] Analysis of Retinal Gangliosides by Hydrophilic Interaction Liquid Chromatography - Electrospray Ionization Tandem Mass Spectrometry
    Berdeaux, Olivier
    Masson, Elodie
    Cabaret, Stephanie
    Athias, Anne
    De Barros, Jean-Paul Pais
    Bretillon, Lionel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [6] Hydrophilic interaction liquid chromatography-electrospray ionization mass spectrometry of tetrodotoxin and its analogs
    Nakagawa, T
    Jang, J
    Yotsu-Yamashita, M
    ANALYTICAL BIOCHEMISTRY, 2006, 352 (01) : 142 - 144
  • [7] Amino acid analysis by hydrophilic interaction chromatography coupled on-line to electrospray ionization mass spectrometry
    T. Langrock
    P. Czihal
    R. Hoffmann
    Amino Acids, 2006, 30 : 291 - 297
  • [8] Amino acid analysis by hydrophilic interaction chromatography coupled on-line to electrospray ionization mass spectrometry
    Langrock, T
    Czihal, P
    Hoffmann, R
    AMINO ACIDS, 2006, 30 (03) : 291 - 297
  • [9] Improvement of Detection Sensitivity of Triglyceride with Methylamine Formate as Ionization Enhancer in Reversed Phase Liquid Chromatography-Electrospray Ionization Mass Spectrometry
    Zhao Hai-Yan
    Gong Can
    Xu Xu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (09) : 1323 - 1329
  • [10] Identification of non-volatile flavor compounds by hydrophilic interaction liquid chromatography coupled to electrospray ionization mass spectrometry.
    Schlichtherle-Cerny, H
    Affolter, M
    Cerny, C
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U64 - U64