Temperature Effects on Electromechanical Response of Deposited Piezoelectric Sensors Used in Structural Health Monitoring of Aerospace Structures

被引:20
|
作者
Hoshyarmanesh, Hamidreza [1 ]
Ghodsi, Mojtaba [2 ]
Kim, Minjae [3 ]
Cho, Hyung Hee [4 ]
Park, Hyung-Ho [3 ]
机构
[1] Univ Calgary, Project NeuroArm, Hlth Res Innovat Ctr, Calgary, AB T2N 4Z6, Canada
[2] Sultan Qaboos Univ, Dept Mech & Ind Engn, Muscat 123, Oman
[3] Yonsei Univ, Dept Mat Sci & Engn, Seoul 03722, South Korea
[4] Yonsei Univ, Sch Mech Engn, Seoul 03722, South Korea
基金
新加坡国家研究基金会;
关键词
piezoelectric sensor; lead zirconate titanate; lead zirconate titanate (PZT; PZT); bismuth titanate (PZT; BiT); temperature effect; electromechanical impedance; aerospace structure; superalloy blade; structural health monitoring; damage detection; THICK-FILMS; IMPEDANCE;
D O I
10.3390/s19122805
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Turbomachine components used in aerospace and power plant applications preferably require continuous structural health monitoring at various temperatures. The structural health of pristine and damaged superalloy compressor blades of a gas turbine engine was monitored using real electro-mechanical impedance of deposited thick film piezoelectric transducers at 20 and 200 degrees C. IVIUM impedance analyzer was implemented in laboratory conditions for damage detection in superalloy blades, while a custom-architected frequency-domain transceiver circuit was used for semi-field circumstances. Recorded electromechanical impedance signals at 20 and 200 degrees C acquired from two piezoelectric wafer active sensors bonded to an aluminum plate, near and far from the damage, were initially utilized for accuracy and reliability verification of the transceiver at temperatures >20 degrees C. Damage formation in both the aluminum plate and blades showed a peak shift in the swept frequency along with an increase in the amplitude and number of impedance peaks. The thermal energy at 200 degrees C, on the other hand, enforces a further subsequent peak shift in the impedance signal to pristine and damaged parts such that the anti-resonance frequency keeps reducing as the temperature increases. The results obtained from the impedance signals of both piezoelectric wafers and piezo-films, revealed that increasing the temperature somewhat decreased the real impedance amplitude and the number of anti-resonance peaks, which is due to an increase in permittivity and capacitance of piezo-sensors. A trend is also presented for artificial intelligence training purposes to distinguish the effect of the temperature versus damage formation in sample turbine compressor blades. Implementation of such a monitoring system provides a distinct advantage to enhance the safety and functionality of critical aerospace components working at high temperatures subjected to crack, wear, hot-corrosion and erosion.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Structural Health Monitoring during Assembly of Aerospace Structures
    Cokonaj, V.
    Alcaide, A.
    Fogeda, B. G.
    Monje, P. M.
    Aranguren, G.
    Barrera, E.
    Ruiz, M.
    Melendez, R.
    [J]. STRUCTURAL HEALTH MONITORING 2013, VOLS 1 AND 2, 2013, : 585 - 592
  • [22] Structural Health Monitoring of Space Structures Using Elastic Waves and Integrated Piezoelectric Sensors
    Zagrai, Andrei
    Peterson, Lukas
    Nwokocha, Funmilola
    Hunter, David
    Franchelle, Logan
    Kessler, Seth
    [J]. PROCEEDINGS OF THE 10TH INTERNATIONAL OPERATIONAL MODAL ANALYSIS CONFERENCE, VOL 1, IOMAC 2024, 2024, 514 : 525 - 537
  • [23] Sensors for process and structural health monitoring of aerospace composites: A review
    Rocha, Helena
    Semprimoschnig, Christopher
    Nunes, Joao P.
    [J]. ENGINEERING STRUCTURES, 2021, 237
  • [24] Embedded Piezoelectric Sensors for Health Monitoring of Concrete Structures
    Hu, Bo
    Kundu, Tribikram
    Grill, Wolfgang
    Liu, Bingkang
    Toufigh, Vahab
    [J]. ACI MATERIALS JOURNAL, 2013, 110 (02) : 149 - 158
  • [25] STRUCTURAL HEALTH MONITORING WITH PIEZOELECTRIC WAFER ACTIVE SENSORS EXPOSED TO IRRADIATION EFFECTS
    Lin, Bin
    Gresil, Matthieu
    Giurgiutiu, Victor
    Mendez-Torres, Adrian E.
    [J]. PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, PVP 2012, VOL 6, PTS A AND B, 2012, : 155 - 161
  • [26] Structural health monitoring of bridges with piezoelectric AE sensors
    Yapar, O.
    Basu, P. K.
    Volgyesi, P.
    Ledeczi, A.
    [J]. ENGINEERING FAILURE ANALYSIS, 2015, 56 : 150 - 169
  • [27] Structural health monitoring with piezoelectric wafer active sensors
    Giurgiutiu, Victor
    [J]. SIXTEENTH INTERNATIONAL CONFERENCE ON ADAPTIVE STRUCTURES AND TECHNOLOGIES, 2006, : 94 - 100
  • [28] STUDY OF AEROSPACE STRUCTURES WITH BONDED PIEZOELECTRIC STRIPS SUBJECTED TO UNSTEADY AERODYNAMIC LOADS FOR STRUCTURAL HEALTH MONITORING
    Han, Yong
    Mateescu, Dan
    Misra, Arun K.
    [J]. PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, VOL 1, 2012, : 697 - 706
  • [29] Influence of temperature and preload force on capacitance and electromechanical impedance of lead zirconate titanate piezoelectric wafer active sensors for structural health monitoring of bolts
    Daniel Sahm
    Daniel Pak
    [J]. Applied Physics A, 2024, 130
  • [30] Influence of temperature and preload force on capacitance and electromechanical impedance of lead zirconate titanate piezoelectric wafer active sensors for structural health monitoring of bolts
    Sahm, Daniel
    Pak, Daniel
    [J]. APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2024, 130 (03):