The Relationship Between Post-Stent Strut Apposition and Follow-Up Strut Coverage Assessed by a Contour Plot Optical Coherence Tomography Analysis

被引:23
|
作者
Kim, Jung-Sun [1 ]
Ha, Jinyong [2 ]
Kim, Byeong-Keuk [1 ]
Shin, Dong-Ho [1 ]
Ko, Young-Guk [1 ]
Choi, Donghoon [1 ]
Jang, Yangsoo [1 ,3 ]
Hong, Myeong-Ki [1 ,3 ]
机构
[1] Yonsei Univ, Coll Med, Severance Cardiovasc Hosp, Div Cardiol, Seoul 120752, South Korea
[2] Sejong Univ, Dept Opt Engn, Seoul, South Korea
[3] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 120752, South Korea
关键词
drug-eluting stent; malapposition; optical coherence tomography; stent coverage; INTRAVASCULAR ULTRASOUND ANALYSIS; ZOTAROLIMUS-ELUTING STENT; NEOINTIMAL COVERAGE; BARE-METAL; VASCULAR-RESPONSE; IMPLANTATION; THROMBOSIS; OCT; MALAPPOSITION; MECHANISMS;
D O I
10.1016/j.jcin.2013.12.205
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis. Background Tracking the fate of interested regions of struts at different time points has not been investigated. Methods Post-intervention and 6-month follow-up optical coherence tomographic evaluations were performed in 82 patients treated with biolimus-(n = 37) or sirolimus-eluting stents (n = 45). Post-stent apposition was classified as embedded, apposed, or malapposed. For volumetric stent evaluation, the post-intervention strut-artery distance and the neointimal thickness at follow-up were measured as a function of the circumferential arc length and longitudinal stent length. Computer-generated contour plots of the strut-artery distance and neointimal thickness were compared. Results The percentages of embedded and malapposed struts after intervention were 1.8% (Interquartile range [IQR]: 0.6% to 6.2%) and 2.3% (IQR: 0.5% to 5.2%), respectively. The percentages of uncovered and malapposed struts at 6 months were 16.0% (IQR: 7.4% to 33.3%) and 0% (IQR: 0% to 0.7%), respectively. The percentage of uncovered struts at 6 months varied significantly with post-stent strut apposition (0% [IQR: 0% to 11.4%] in embedded, 16.3% [IQR: 8.1% to 31.3%] in apposed, and 26.8% [IQR: 0% to 56.3%] in malapposed, p < 0.001 for all pairwise comparisons). In lesions without tissue prolapse, embedded struts were all covered (100% covered struts) compared with those with tissue prolapse (76.8% covered, p < 0.001). Conclusions The optical coherence tomography-guided optimization of stent strut apposition enhances strut coverage at follow-up. This comprehensive method for evaluating strut apposition may provide more useful information to understanding the serial changes in strut coverage. (Neointimal Coverage After Implantation of Biolimus Eluting Stent With Biodegradable Polymer: Optical Coherence Tomographic Assessment According to the Treatment of Dyslipidemia and Hypertension and the Types of Implanted Drug-Eluting Stents; NCT01502904) (C) 2014 by the American College of Cardiology Foundation
引用
收藏
页码:641 / 651
页数:11
相关论文
共 50 条
  • [41] The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography
    Tanigawa, Jun
    Barlis, Peter
    Dimopoulos, Konstantinos
    Dalby, Miles
    Moore, Philip
    Di Mario, Carlo
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 134 (02) : 180 - 188
  • [42] Increased circumferental vessel wall calcification predisposes to stent strut malapposition as assessed by optical coherence tomography
    Paulo, M.
    Lindsay, A. C.
    Alegria-Barrero, E.
    Chan, P. H.
    Foin, N.
    Di Mario, C.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 : 1006 - 1006
  • [43] Malapposition and strut coverage following implantation of the Resolute Integrity stent in patients with ST elevation myocardial infarction assessed by optical coherence tomography
    Hougaard, M.
    Hansen, H. S.
    Thayssen, P.
    Junker, A.
    Antonsen, L.
    Jensen, L. O.
    [J]. EUROPEAN HEART JOURNAL, 2016, 37 : 679 - 679
  • [44] Evaluation of long-term follow-up with neointimal coverage and stent apposition after sirolimus-eluting stent implantation by optical coherence tomography
    Li, Shan
    Gai, Luyue
    Yang, Tingshu
    Zhang, Li
    Xu, Xiuli
    Bai, Qicai
    Xu, Hang
    Wang, Yutang
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) : 768 - 775
  • [45] Validation Study of an Automated Algorithm to Assess Stent Strut Apposition and Neointima Coverage of In-vivo Intra-Coronary Optical Coherence Tomography Images
    Adriaenssens, Tom
    Ughl, Gtovanni
    Onsea, Kevin
    Kayaert, Peter
    Dubots, Christophe
    Sinnaeve, Peter
    Coosemans, Mark
    Dhooge, Jan
    Desmet, Walter
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B14 - B14
  • [46] Early coverage of drug-eluting stents analysed by optical coherence tomography: evidence of the impact of stent apposition and strut characteristics on the neointimal healing process
    Lee, Renick
    Foin, Nicolas
    Ng, Jaryl
    Allen, John
    Soh, Nicole
    Ang, Ivy
    Shim, Winston
    Torii, Ryo
    Wong, Philip
    [J]. EUROINTERVENTION, 2016, 12 (05) : E605 - E614
  • [47] An Optical Coherence Tomography Assessment of Stent Strut Apposition Based on the Presence of Lipid-Rich Plaque in the Carotid Artery
    Liu, Rui
    Jiang, Yongjun
    Xiong, Yunyun
    Li, Min
    Ma, Minmin
    Zhu, Wusheng
    Yin, Qin
    Li, Wei
    Xu, Gelin
    Liu, Xinfeng
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (06) : 942 - 949
  • [48] Clinical Impact of Post-Stent Optical Coherence Tomography Findings: Two-year Follow-up from a Single Center Registry
    Fan, Yuqi
    Matsumura, Mitsuaki
    Jeremias, Allen
    Goldberg, Alec
    Ishida, Masaru
    Fujino, Akiko
    Shlofmitz, Evan
    Alexandru, Dragos
    Haag, Elizabeth
    Ali, Ziad
    Moses, Jeffrey W.
    Mintz, Gary
    Shlofmitz, Richard
    Maehara, Akiko
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B30 - B30
  • [49] Effect of High-intensity Statin Therapy on Strut Coverage After Drug-eluting Stent Implantation, Serial Follow-up Optical Coherence Tomographic Analysis
    Kim, Jeong Hun
    Kim, Jung-Sun
    Shin, Dong-Ho
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. CIRCULATION, 2015, 132
  • [50] Optical coherence tomography assessment of early stent strut coverage in patients treated with a thin-strut bare cobalt-chromium stent coated with silicon carbide
    Samim, Mariam
    Agostoni, Pierfrancesco
    Voskuil, Michiel
    Belkacemi, Anouar
    Doevendans, Pieter A.
    Stella, Pieter R.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 157 (02) : 291 - 292