Spectrofluorimetric method for determination of aluminium with chromotropic acid and its application to water samples

被引:26
|
作者
Park, CI [1 ]
Cha, KW [1 ]
机构
[1] Inha Univ, Dept Chem, Inchon 402751, South Korea
关键词
Al(III); chromotropic acid; fluorimertic determination;
D O I
10.1016/S0039-9140(99)00351-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and sensitive method for the trace level determination of aluminium based on the formation of a 1:1 complex with chromotropic acid (1,8-dihydroxynaphthlene-3,6-disulfonic acid) in an methanol medium is reported. The fluorescence intensity of the system was 50 times greater than that of the system without aluminium. This method is very sensitive and selective for the direct determination of aluminium ion. The fluorescence is excited at 346 nm and measured at 370 nm. The optimum conditions are a chromotropic acid concentration of 5.0 mi (1.0 x 10(-4) M) and pH 4.0 +/- 0.5 (acetic acid-sodium acetate buffer). The fluorescence intensity is a linear function of the concentration of AI(III) in the range 2-100 ng ml(-1) and the detection limit is 1.0 ng ml(-1). The method has been applied successfully to the determination of trace amount of AI(III) in tap, river and sea-water samples. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:769 / 774
页数:6
相关论文
共 50 条
  • [41] A new spectrofluorimetric method for determination of losartan potassium in rabbit plasma and its application to pharmacokinetic study
    Demirkaya-Miloglu, Fatma
    Yaman, Mehmet Emrah
    Kadioglu, Yucel
    LUMINESCENCE, 2015, 30 (01) : 53 - 59
  • [42] DETERMINATION OF IONIZATION-CONSTANT OF CHROMOTROPIC ACID USING POTENTIOMETRIC METHOD
    KAS, TS
    EGOROV, AM
    ZHURNAL FIZICHESKOI KHIMII, 1972, 46 (08): : 2151 - &
  • [43] EFFECT OF REAGENT IMPURITY ON CHROMOTROPIC-ACID METHOD FOR DETERMINATION OF CHLORIDE
    AFGHAN, BK
    RYAN, JF
    ANALYTICAL CHEMISTRY, 1976, 48 (06) : 912 - 915
  • [44] DETERMINATION OF TRACE WATER IN ORGANIC-SOLVENTS BY A SPECTROFLUORIMETRIC METHOD
    CI, YX
    JIA, X
    TALANTA, 1984, 31 (07) : 556 - 558
  • [45] Synchronous spectrofluorimetric determination of naphthalene in water samples using mixed micellar medium
    El-Sayed Okeil, S.M. (sherif_okeil@hotmail.com), 1600, AOAC International (97):
  • [46] Synchronous Spectrofluorimetric Determination of Naphthalene in Water Samples Using Mixed Micellar Medium
    Ghonim, Omar Abdel-Aziz
    El-Kosasy, Amira Mabrouk
    Okeil, Sherif Mahmoud El-Sayed
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (03) : 921 - 927
  • [47] Highly selective and sensitive spectrofluorimetric method for determination of cypermethrin in different environmental samples
    Mian Muhammad
    Sikandar Khan
    Gul Rahim
    Walaa Alharbi
    Khadijah H. Alharbi
    Environmental Monitoring and Assessment, 2022, 194
  • [48] Determination of Isoproturon in Environmental Samples using the QuEChERS Extraction-Spectrofluorimetric Method
    Muhammad, Mian
    Rasul Jan, Muhammad
    Shah, Jasmin
    Ara, Behisht
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2019, 38 (12) : 2614 - 2620
  • [49] Validation of a Spectrofluorimetric Method for the Determination of Thiram and Thiophanate Methyl Fungicides in Environmental Samples
    Sharma, Devender Kumar
    Singh, Kushal
    Raj, Pushap
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2020, 7 (04): : 483 - 495
  • [50] Highly selective and sensitive spectrofluorimetric method for determination of cypermethrin in different environmental samples
    Muhammad, Mian
    Khan, Sikandar
    Rahim, Gul
    Alharbi, Walaa
    Alharbi, Khadijah H.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2022, 194 (12)